Loading…
Loading…
0 results • Latest
No matching tenders
Try removing a filter to broaden results
This organisation has published 2 tenders in the past.
View results and past tenders →New tenders appear here as soon as they are published. Until then, here are the most recent tenders and results from 4014 Field Hospital.
Multifunction Machines, Line Intractive UPS with AVR Average Turn Over of Last 3 Years 5 Lakh (s) Experience with Gov. Required 5 Year (s) Multifunction Machines ( 1 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values Ungrouped Type of Machine Multifunction Machine * Print Technology Inkjet Inkjet, Laser Cartridge Technology Ink With Composite Cartridge, With Separate Drum and Toner, Ink Type of Printing Colour Mono, Colour Platen/Flatbed Size A4 A3, A4, Legal Paper Size (Original/Image) A4/A4 A3/A3, A4/A4, Legal/Legal RAM size (MB) 0 * Hard Disk Capacity(GB) 0 Any applicable numeric value Minimum Speed per Minute in A4 Size- Mono (PPM) 8 Any applicable numeric value 1/6 Minimum Speed per Minute in A4 Size- Colour (PPM) 5 Any applicable numeric value Minimum Speed per Minute in A3 Size- Mono(PPM) 0 * Minimum Speed per Minute in A3 Size- Colour(PPM) 0 * Scanning Feature Availability Yes Yes, No Duplexing Feature Availability No Yes, No Networking Feature Availability No Yes, No If yes, Network Interface NA * Faxing Feature Availability No Yes, No Speed of Fax, If Fax Feature is available NA * Original Feed Type Platen Platen, ADF, DADF/RADF, SPDF Feeder Capacity (Number) 0 * Wi-Fi Capability Yes Yes, Wi-Fi Type Wi fi 802.11 b/g/n * Number of Main Tray(Number) 1 Any applicable numeric value Total Main Tray Capacity 50 * Bypass Facility Yes * Bypass Tray Capacity 50 * Yield of the cartridge/Ink Tank/Ink Pack (for C, M, Y & K individually) supplied with Machine(Number of prints) 13000 * Life of Drum in terms of number of Prints in case of Separate Drum and Toner cartridge technology(Number of Prints) 0 * Duty Cycle/Month (Number of Prints) 1000 * 2/6 BIS Registration under CRS of Meity Yes * BIS Registration Number R-41000760 * Operating Temperature Range (Degree C) 40 * Operating Humidity (%RH) 80 * On Site OEM Warranty (Year) 1 1, 2, 3, 4, 5 * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Sanjeev M Waghmore 194101, 4014 Fd Hosp, C/O 56 APO, kiari pin - 904014 1 15 Line Intractive UPS With AVR ( 2 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Rating in KVA/min VAH capacity of battery (KVA/VAH) 1.0/216 * Technology MOSFET-PWM MOSFET-PWM, IGBT- PWM Type of battery SMF-VRLA confirming to JISC-8702 Pt 1, 2 &3 SMF-VRLA confirming to JISC-8702 Pt 1, 2 &3 Rated Output (Volt) Single phase sinewave 230v AC, 50Hz Single phase sinewave 230v AC, 50Hz, Single Phase Quasi-Sin-wave 230 V AC, 50 Hz Degree of protection IP-21 IP-21, IP 20 Inverter Efficiency (%) >/= 70% >/= 60%, >/= 70% Warranty for the battery from the date of delivery 1 year 1 year, 3 Years Warranty for Line Interactive UPS 2 Years 1 Year, 2 Years, 5 Years, 3 Years 3/6 Installation and commissioning instructions Yes * CONSTRUCTIONAL Type of enclosure Mild steel * AC out put for printer (not through inverter) No Yes, No Inverter out put socket AC out put for printer (not through inverter) 3 Three pin 2 Three pin, 3 Three pin, Hard wiring, Not applicable FUNCTIONAL Total harmonic distorsion (%) * Input (Volt) Single phase sinewave(160-280v) * Switching over time (Mili sec) Maximum 10 milli seconds * Overload Time (Minutes) >/= 10 minutes * Load power factor >/= 0.6 * Variation in AVR output in AC mode (%) AVR (Voltage regulation) output voltage in AC Mode 230 Volts +/-9%, 50 +/-3 Hz * Overload (%) >/=10% * Variation in output voltage in battery mode (%) (UPS output voltage in battery mode) 230 Volts +/- 10% * Variation on output frequency in battery mode (Hz) =0.5 * PROTECTION Protection against (over discharge) discharge per 12v battery (Volt) 10.5 * Protection for outside input voltage range: If Input voltage goes outside the range 160 to 280 Volts, the system shall switch over to battery mode Yes * Protection against short circuit of UPS Yes * Protection for over voltage and over load Yes * 4/6 REPORTS AND CERTIFICATIONS Damp heat Test at 45 degree, RH -95% for 2-cycle as per IS:9000 pt-5/sec-1 Yes * Dry heat Test at 45 degree for 16 Hrs as per IS:9000 pt-3/sec-5 Yes * Cold Test as per IS:9000 pt-2/sec-4 Yes * Availability of the type test report from central Govt./NABL/ILAC Accredited Lab Yes * Type Test certificate no. and date - * Name Of Lab - * Address of Lab - * As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Yes * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Sanjeev M Waghmore 194101, kiari pin - 904014 2 15