Loading…
Loading…
45 results • Latest
Buy Back - Lead Acid starter Batteries
automotive vehicles pneumatic tyres
OEM Cartridge/Consumable, OEM Cartridge Consumable
OEM Cartridge/Consumable, OEM Cartridge Consumable
e rickshaw for carrying goods
bedclothes rubberised coir mattress cushions and pillows hospital mattresses and pillows
DSLR/COMPACT/HANDHELD CAMCORDER or VIDEO CAMERAS
trolley bags-office bags, Suitcase, Brief Case
Portable Fire Extinguishers IS 15683
Portable Fire Extinguishers IS 15683
Portable Fire Extinguishers IS 15683
Portable Fire Extinguishers IS 15683
under water communication set
digital earth resistance meter MSME Exemption For Years Of Experience And Turnover Yes Digital Earth Resistance Meter ( 2 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values FEATURES Display type 3½ digit LCD display 3½ digit LCD display, 4 digit LCD display Measurable Earth resistance range selection Auto ranging Auto ranging, Range selection through a switch Method for resistance measurement 3-pole 2-pole, 3-pole, 4-pole Counts 6000 2000, 3000, 4000, 6000, 10000 Number of the stakes 3 * Material of the stakes - * Length of the Stakes 48 * Diameter of the Stakes 10 * Number of the Test Leads 3 * Length of the Test 25 * 1/4 Leads Number of Test Leads with Clamps 3 * Length of Test Leads with Clamps 0 * OTHER FEATURES Internal Memory (Number of record) 0 * External memory Through USB * Interface USB * Minimum Open Circuit Output voltage 48 * Over range indication Available * Stakeless test(Clamp On) false true, false MEASUREMENTS Number of Measurable Range 3 * Measurable Ranges (Ohm) 0.01 to 19.99, 0.1-199.9, 0.1 to 200, 20 to 200, 100 to 200, 1 to 1999 * Measurable Earth resistance resolution (Ohm) 0.01, 0.1, 0.5, 1, 5, 10, 50 * Measurable Earth resistance accuracy ±6 % ±1 count * Facility to Measure Earth Voltage false * If Yes, Measurable Earth Voltage range 0 * If Yes, Measurable Earth Voltage accuracy 0 * If Yes, Measurable Earth Voltage resolution 0 * Other features - * GENERIC Weight of the tester 850 * Dimensions (cm x cm x cm) - * POWER REQUIREMENTS Type of Battery Non- Rechargeable (Alkaline) * if rechargeable, then chemistry of the battery NA * if Non-rechargeable, then size of the battery cell 9-V rectangular battery * 2/4 Number of non- rechargeable the battery/cell 1 * Voltage of rechargeable Battery 9 * Capacity of rechargeable battery (milliamperehour) 1499 * Suitable charger adaptor provided NA * Battery backup time 10 * Low battery indication Available * ACCESSORIES Details of All connecting Cables and accessories to be supplied along with the tester - * TEST REPORT DETAILS The equipment supplied with calibration certificate yes * conformity to Dry Heat for 16 hours at a temperature of 55 degree C in accordance with IS:9000/part-3/sec tion-5/1977 latest true * conformity to Damp Heat (Cyclic)Test for 2 Cycles of 24 h each at a temperature of 40 degree C & 95% RH in accordance with IS:900 0/part-5/section-1 1991 latest true * conformity to Cold test at 0 degree C for four hours as per IS: 9000( Part 2/section 4) latest true * Availability of Test Reports from Central Govt/NABL approved ILAC acredited lab to prove confromity to the specification true * Test Report Number and date for the specification test - * Name and address of the Lab for the specification test - * 3/4 * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Nishi Kant Sarkhel 500011, Air Force Station Begumpet Bowenpally Secunderabad 2 15
automotive vehicles pneumatic tyres Automotive Vehicles Pneumatic Tyres ( 7 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values Ungrouped Category Of Pneumatic tyres Normal Road Tyre Normal Road Tyre, Special use Tyre: mixed used, Restricted speed: snow tyre Tyres With Tube With Tube, Tubeless, Without Tube Conformity to Indian Standrad for Pneumatic Tyres IS:15627 latest for Automotive vehicles: Pneumatic tyre for two and three wheeled motor Vehicles IS:15627 latest for Automotive vehicles: Pneumatic tyre for two and three wheeled motor Vehicles, IS:15633 latest for Automotive vehicles: Pneumatic tyre for passenger car Vehicles- Diagonal and radial ply, IS:15636 latest for Automotive vehicles: Pneumatic tyre for commercial Vehicles- Diagonal and radial ply Conformity to Indian Standrad for IS:13098 latest for Automotive vehicles: IS:13098 latest for Automotive vehicles: 1/4 Pneumatic Tubes Tubes for Pneumatic tyre Tubes for Pneumatic tyre, NA for Tubeless TYRES ISI MARKED (for Tyres) Yes Yes CM/L No and validity date)(for Tyres - * ISI MARKED (for Tubes) Yes Yes, NA for Tubeless and without tube CM/L No and validity date(for tubes) - * Type of tube Class-A * Manufactures name and Trade Name - * Tyre-size Designations 750X16 * Tube-size Designations 750x16 * Structure of Tyre Bias-belted Diagonal or bias ply, Bias-belted, Radial, Reinforced or Extra Load Ply Rating 13 * Speed Category - * Load indicas - * Side Well (mm) -1 * Inner area of Tyers (mm) -1 * Section Width (min)(mm) -1 * Overall Width (max)(mm) -1 * Section Height (mm) -2 * Nominal Aspect Ratio(mm) -2 * Outer diameter (min)(mm) 980 Any applicable numeric value Nominal Rim Diameter(mm) 17 Any applicable numeric value Maximum load Rating(%) -2 Any applicable numeric value Conformity to AIS-044 Yes * Availability of Type Test Report covering complete test parameters as per relevant BIS YES * 2/4 spcification latest for Tyre type, from any ILAC/NABL accredited/Central Gov. LAB. Test cetificate No. - * Test Report Date - * Name and address of the Lab where test Conducted - * Others Certificate ie ROHS, WHO, GMP etc - * Warranty Time 1 1, 2, 3 * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Nishi Kant Sarkhel 500011, Air Force Station Begumpet Bowenpally Secunderabad 7 15
lead acid battery Lead Acid Battery ( 150 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Types of Lead Acid of Battery Small sized Valve Regulated Lead -Acid Batteries (SMF) conforming to JISC: 8702/1998 (Part 1, 2 & 3) with latest amendments Small sized Valve Regulated Lead -Acid Batteries (SMF) conforming to JISC: 8702/1998 (Part 1, 2 & 3) with latest amendments, Statinary Lead-Acid Batteries (with tubular positive plates) in Monobloc Container conforming to IS:13369/1992, Stationary cells and Batteries, Lead Acid Type (With Tubular Positive Plates) conforming to IS:1651/1991, Stationary Valve Regulated Lead Acid Batteries conforming to IS:15549/2005, Lead- Acid Storage Batteries 1/4 for Motor Vehicles with Light weight and High Cranking Performance conforming to IS:14257/1995, Lead- Acid Storage Batteries for Motor Vehicles conforming to IS:7372/1995 Nominal Voltage of Battery (volts) 12.0 Volt 12.0 Volt Material of container Fibre Reinforced Plastics (FRP) Hard Rubber, Fibre Reinforced Plastics (FRP), Polypropylene, ABS Rated Capacity at C20 discharge (AH) 7.2 7.2 Warranty (Years) 1 Year 1 Year, 2 Years, 3 Years, 4 Years, 5 Years Battery Condition Dry Charged * CONSTRUCTIONAL Dimensions (L x W x H) (mm x mm x mm) As per relevant IS Specifications * Volume of Electrolyte (ml) DRY * Weight of Dry Battery (Kg) shall be as per relevant IS: Specn., corresponding Ah Yes. * No.of cells per Battery (No.) 6 Cells for 12 Volt battery * CERTIFICATIONS Availability of Test Reports from Central Govt./NABL/ILAC accrediated Lab showing conformity to the specifications Yes * Address of the Lab VIP ROAD, KOLKATA, WEST BENGAL-700020 * Name of the Lab R&D, EXIDE INDUSTRIES LTD. * Test Report No. 44100124146 * Test Report Date 11.9.17 * Compulsory Registration (CRS) of BIS for safety as per IS 16046 as applicable. Secondary Cells and Yes * 2/4 (Batteries containing Alkaline or other non- acid Electrolytes-Safety Requirements for Portable sealed secondary cells, and for Batteries made from them for use in portable applications * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Nishi Kant Sarkhel 500011, Air Force Station Begumpet Bowenpally Secunderabad 150 15
Hard disk drives Hard Disk Drives ( 20 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values Specification Type of Drive SAS SSD, SAS, NL SAS, Flash Capacity of Drive (GB) 1024 1024 Media Diameter (cm) 10.2 * Rotational Speed (rpm) 7200 * Interface Type SATA * Synchronous Transfer Rate (Maximum) (MB/s) 600 * Buffer (MB) 64 * Cache (MB) 64 * Rated Power (Watt) 4 * Rated for 24/7/365 operation Yes * Physical Size(Height) (mm) 26.1 * Physical Size(Width) (mm) 101.6 * 1/3 Operating Temperature Range (Degree C) 0-60 * Performance (Sequential Read) (MB/s) 300 * Performance (Sequential write) (Mb/p) 210 * Warranty (Years) 2 1, 2, 3 * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Nishi Kant Sarkhel 500011, Air Force Station Begumpet Bowenpally Secunderabad 20 15
Online UPS ( 4 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Rating in KVA (KVA) 5.0 KVA 5.0 KVA Technology IGBT-PWM with inbuilt isolation transformer IGBT-PWM with inbuilt isolation transformer Input Power single phase 160V - 260V sinewave, 50Hz single phase 160V - 260V sinewave, 50Hz, Three phase 300 V - 450V sinewave, 50Hz Output power Single phase 230V +/-1% sinewave 50 Hz Single phase 230V +/-1% sinewave 50 Hz, 3 Phase 400V +/-1% with alternative user setable setting of 380V +/-1% 50 Hz Backup time (Minutes) 120 120 Minimum VAH (VAH) 16000 400-640000 Warranty for UPS (Years) 2 2 Movable trolly for Batteries Without trollery but with rack With, Without, Without trollery but 1/6 with rack Warranty for battery 2 2 Degree of Protection IP20 IP21, IP20 Cabling 5 meters for input and out put With With, Without Paralleling kit for synchronising Without With, Without Installation and Commissioning Yes * CONSTRUCTIONAL Minimum thickness of M.S.Sheet Enclosure duly painted (mm) 1.2 * Type of Battery SMF-VRLA conforming to JISC:8702(Pt.I, II&III) * FUNCTIONAL Maximum overshoot and Under shoot of output rated voltage 4 * Voltage Regulation from no load to full load (%) </= 3% * 20% Overload limit for minimum 10 minutes Yes * Overall Efficiency (%) >/=90% * Total Harmonic Distortion(THD) (%) Maximum 3% * 50% Overload limit for minimum 1 minutes Yes * PROTECTION Protection for under voltage at battery terminal at 10.5V per 12 V battery. Yes * Protection of Over voltage, Short Circuit & over load at UPS output terminal Yes * METERING AND INDICATIONS Digital Metering in UPS for AC Input Voltage, Output AC Volt age, Current, Frequency, Battery Voltage and Current Yes * Indicators for mains presence, Battery charging and discharging, Output Over Load, Low Battery Voltage Yes * REPORTS AND Damp Heat : in Yes * 2/6 CERTIFICATION accordance with IS:9000(part 5/sec.2)1981 at Temperature of 40 degree C, two cycles of (12+12) hours each 2007) Dry Heat Test : in accordance with IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) at 55 degree C for 16 hrs Yes * Cold Test : in accordance with IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) at -10 degree C for 4 hrs. Yes * Availability of the Type Test Report from Central Govt. NABL/ILAC Accredited lab covering all technical requirements. Yes * Type Test Certificate No. - * Type Test Certificate date - * Name of Lab - * Address of Lab - * As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Not applicable presently * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Nishi Kant Sarkhel 500011, Air Force Station Begumpet Bowenpally Secunderabad 4 15
electrocardiography ekg/ecg units Electrocardiography Ekg/ecg Units ( 1 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values FEATURES Mobility, portability Protective splashproof case for clean storage and safe transport * Heart rate measurement range to be at least 30 to 250 bpm, with accuracy better than ± 5 bpm yes * Heart rate trend display of at least previous 24 hours yes * In built Software and/or standard of communication yes * Heat Dissipiation: Should maitain nominal Temp and the heat should be disbursed through a exhaust cooling fan yes * 1/4 User interface manual * Noise Lavel (dba) - * Electrical protection provided by fuses in both live and neutral supply lines yes * Operating condition: Capable of operating continuously in ambient temperature of 0 to 50 deg C and relative humidity of 15 to 90% in ideal circumstances yes * Arrhythmia detection facility required; minimum gradation of 1 bpm yes * Functional requirements: electricity;AC-powered; bedside device designed to continuously detect, measure, and display a patient’s electrocardiogram through leads and sensors attached to the patient, it also typically display heart rate, the device is typically equipped with audible and/or visual alarms that are triggered when the patien's parameters drop below or exceed pre-set limits: Continuous display of patient ECG and heart rate on screen, Allows display of single, 5 lead ECG or simultaneous display of at least 5 waves selected from up to 12 points Operator can set audiovisual alarm levels for low or high heart rate Operates from mains voltage or from internal rechargeable battery yes * Power consumption - * 2/4 weight - * Power cable length (meter) 3 METER OR MORE * Display must allow easy viewing in all ambient light levels yes * Audiovisual alarms required: high and low heart rate; operator variable settings, cardiac arrhythmia, sensor/wire disconnected, low battery yes * STANDARDS AND SAFETY, CERTIFICATIONS Certification(s) US FDA approved product, ISO 13485 Certificate For Quality Standard, Electrical Safety Conforms To Standards For Electrical Safety IEC-60601-1 Shall Meet IEC-60601-1-2 (General Requirements For Safety - Electromagnetic Compatibility) And IEC 60601-2-25 (Essential Performance Of Electrocardiographs), C E Approved product * MISCLANEOUS Warranty (years) 3 3, 5 (or higher) power input and frequency 220 To 240V, 50 Hz AC * Certificate of Calibration and Inspection to be provided YES * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Nishi Kant Sarkhel 500011, Air Force Station Begumpet Bowenpally Secunderabad 1 15
Line Intractive UPS With AVR ( 40 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Rating in KVA/min VAH capacity of battery (KVA/VAH) 1.0/168 * Technology MOSFET-PWM MOSFET-PWM, IGBT- PWM Type of battery SMF-VRLA confirming to JISC-8702 Pt 1, 2 &3 SMF-VRLA confirming to JISC-8702 Pt 1, 2 &3 Rated Output (Volt) Single Phase Quasi-Sin- wave 230 V AC, 50 Hz Single phase sinewave 230v AC, 50Hz, Single Phase Quasi-Sin-wave 230 V AC, 50 Hz Degree of protection IP-21 IP-21, IP 20 Inverter Efficiency (%) >/= 60% >/= 60%, >/= 70% Warranty for the battery from the date of delivery 1 year 1 year, 3 Years Warranty for Line Interactive UPS 2 Years 1 Year, 2 Years, 5 Years, 3 Years 1/4 Installation and commissioning instructions Yes * CONSTRUCTIONAL Type of enclosure ABS * AC out put for printer (not through inverter) No Yes, No Inverter out put socket AC out put for printer (not through inverter) 3 Three pin 2 Three pin, 3 Three pin, Hard wiring, Not applicable FUNCTIONAL Total harmonic distorsion (%) </= 40% * Input (Volt) Single phase sinewave(160-280v) * Switching over time (Mili sec) Maximum 10 milli seconds * Overload Time (Minutes) >/= 10 minutes * Load power factor >/= 0.6 * Variation in AVR output in AC mode (%) AVR (Voltage regulation) output voltage in AC Mode 230 Volts +/-9%, 50 +/-3 Hz * Overload (%) >/=10% * Variation in output voltage in battery mode (%) (UPS output voltage in battery mode) 230 Volts +/- 10% * Variation on output frequency in battery mode (Hz) </=0.5 * PROTECTION Protection against (over discharge) discharge per 12v battery (Volt) 10.5 * Protection for outside input voltage range: If Input voltage goes outside the range 160 to 280 Volts, the system shall switch over to battery mode Yes * Protection against short circuit of UPS Yes * Protection for over voltage and over load Yes * 2/4 REPORTS AND CERTIFICATIONS Damp heat Test at 45 degree, RH -95% for 2-cycle as per IS:9000 pt-5/sec-1 Yes * Dry heat Test at 45 degree for 16 Hrs as per IS:9000 pt-3/sec-5 Yes * Cold Test as per IS:9000 pt-2/sec-4 Yes * Availability of the type test report from central Govt./NABL/ILAC Accredited Lab Yes * Type Test certificate no. and date - * Name Of Lab - * Address of Lab - * As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Yes * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Nishi Kant Sarkhel 500011, Air Force Station Begumpet Bowenpally Secunderabad 40 15
under water communication set Under Water Communication Set ( 2 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values Specification Type of Under Water Communication Set Wireless Wireless, Wired Capability of Voice Communication The equipment is capable to establish and maintain voice communication between the Divers under water and the attendant/Supervisor of the Surface Team as well as between all the divers during a diving operation * Number of divers permitted for clear under water commuication 4 * Depth upto which equipment is capable to work under water (meter) 10 * 1/5 Number of channels permitted for continuous under water communication (Number) 2 * Ingress Protection from water (IP Rating) IPX4 * Volume Control & Squelch Facility on Surface Panel Available * Minimum Range of Line of Sight Communication (Meter) 400 * Minimum Length of the umbilical provided (mtr.) NA * Strength of the umbilical provided NA * Suitability of the system for continuous under water usage (Hour) Minimum 2 * Headset & Microphone with the Surface unit to enable handsfree movement of the Supervisor on Diving Site Available * Weight of Diver Unit (1 Kg +/- 10%) (Kg) 350 * Weight of Surface Panel (6 Kg +/- 10%) (Kg) 350 * Diver Unit Pressure Compensated upto 10 meters +/- 10% (Meter) 1 * Operating Temperature Range (Degree C) 10-50 * Components/connector s used are of fragile material and compatible with each other with quick removal/system Yes * The panel and other exposed parts are of water resistant material and incorporate water proof switches that avoid the Yes * 2/5 ingress of water (Degree C) High fidelity of the speech in between surface attendant and under water diver Yes * Diver unit with Bone conductor and speaker with attachment to the diving set mask Yes * Surface unit with speaker, amplifiers and headphone Yes * Rechargeable cells/batteries for Diver's unit and surface units Available * Battery Back up Time (Minimum) (Hour) 14 * Charger for the cells batteries Available * Carry case Available * Repair Kit/Tools Kit Available * Operational and technical manual Available * Availability of satisfactory performance certificate from NDRF to prove conformity to the specification Yes * Availability of Test Reports from Central Govt/NABL approved ILAC acredited lab to prove conformity to the specification Yes * Test Report Number - * Test Report Date - * Name of the Lab - * On Site OEM Warranty (Year) 1 1, 2, 3 * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 3/5 1 Nishi Kant Sarkhel 500011, Air Force Station Begumpet Bowenpally Secunderabad 2 15
lead acid battery Lead Acid Battery ( 24 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Types of Lead Acid of Battery Stationary Valve Regulated Lead Acid Batteries conforming to IS:15549/2005 Small sized Valve Regulated Lead -Acid Batteries (SMF) conforming to JISC: 8702/1998 (Part 1, 2 & 3) with latest amendments, Statinary Lead-Acid Batteries (with tubular positive plates) in Monobloc Container conforming to IS:13369/1992, Stationary cells and Batteries, Lead Acid Type (With Tubular Positive Plates) conforming to IS:1651/1991, Stationary Valve Regulated Lead Acid Batteries conforming to IS:15549/2005, Lead- Acid Storage Batteries for Motor Vehicles with 1/5 Light weight and High Cranking Performance conforming to IS:14257/1995, Lead- Acid Storage Batteries for Motor Vehicles conforming to IS:7372/1995 Nominal Voltage of Battery (volts) 2.0 Volt 2.0 Volt, 6.0 Volt, 12.0 Volt Material of container Polypropylene Hard Rubber, Fibre Reinforced Plastics (FRP), Polypropylene, ABS Rated Capacity at C20 discharge (AH) 200 200 Warranty (Years) 2 Years 1 Year, 2 Years, 3 Years, 4 Years, 5 Years Battery Condition Dry Charged * CONSTRUCTIONAL Dimensions (L x W x H) (mm x mm x mm) As per relevant IS Specifications * Volume of Electrolyte (ml) 2300ml * Weight of Dry Battery (Kg) shall be as per relevant IS: Specn., corresponding Ah Yes. * No.of cells per Battery (No.) 1 Cell for 2 Volt battery * CERTIFICATIONS Availability of Test Reports from Central Govt./NABL/ILAC accrediated Lab showing conformity to the specifications Yes * Address of the Lab EXIDE INDUSTRIES LIMITED, HOSUR TALUK, KRISHNAGIRI, TAMIL NADU-625103 * Name of the Lab EXIDE INDUSTRIES LIMITED * Test Report No. 0983 * Test Report Date 23.10.2016 * Compulsory Registration (CRS) of BIS for safety as per IS 16046 as applicable. Secondary Cells and YES * 2/5 (Batteries containing Alkaline or other non- acid Electrolytes-Safety Requirements for Portable sealed secondary cells, and for Batteries made from them for use in portable applications * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Nishi Kant Sarkhel 500011, Air Force Station Begumpet Bowenpally Secunderabad 24 15
trolley bags-office bags, Suitcase, Brief Case Trolley Bags-office Bags, Brief Case ( 10 ) Technical Specifications Specification Specification Name Values Allowed Values SPECIFICATION MATERIAL Material Polyester - Inside material Fabric Material of telescopic extension (Applicable only for trolley bag) YES Tyre Material (Applicable only for trolley bag) Polymer Coated COLOUR Colour/Design Black TYPE Type Office trolley bag Office bag men, Officce bag women, Office trolley bag Pack Hand Back, Hand Hanging Strap false true, false Closure Zipper Zipper, Lock Lock With number lock With number lock, Pad lock, Without lock Number of Tyre Wheels (Applicable only for trolley bag) 2 - Tyre roller Bush Bush, Bearing, N/A 1/3 Mechanism (Applicable only for trolley bag) Water resistance false true, false COMPARTMENTS Number of compartments 4 Lap top compartment true true, false Number of external pockets 3 CAPACITY AND DIMENSION Material mass (gm/sq.m) 200 Mass of Bag (gms) 3300 Material thickness (mm) 3 Length (cm) 41 Width (cm) 35 Height (cm) 44 Weight carying capacity (kgs) 20 Diameter of wheel (Applicable only for trolley bag) (mm) 50 WARRANTY Warranty (Years) 3 1, 2, 3 * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Nishi Kant Sarkhel 500011, Air Force Station Begumpet Bowenpally Secunderabad 10 15
electrocardiography ekg/ecg units Electrocardiography Ekg/ecg Units ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values FEATURES Mobility, portability Protective splashproof case for clean storage and safe transport - Heart rate measurement range to be at least 30 to 250 bpm, with accuracy better than ± 5 bpm yes - Heart rate trend display of at least previous 24 hours yes - In built Software and/or standard of communication yes - Heat Dissipiation: Should maitain nominal Temp and the heat should be disbursed through a exhaust cooling fan yes - User interface manual - Noise Lavel (dba) - - Electrical protection provided by fuses in both live and neutral yes - 1/4 supply lines Operating condition: Capable of operating continuously in ambient temperature of 0 to 50 deg C and relative humidity of 15 to 90% in ideal circumstances yes - Arrhythmia detection facility required; minimum gradation of 1 bpm yes - Functional requirements: electricity;AC-powered; bedside device designed to continuously detect, measure, and display a patient’s electrocardiogram through leads and sensors attached to the patient, it also typically display heart rate, the device is typically equipped with audible and/or visual alarms that are triggered when the patien's parameters drop below or exceed pre-set limits: Continuous display of patient ECG and heart rate on screen, Allows display of single, 5 lead ECG or simultaneous display of at least 5 waves selected from up to 12 points Operator can set audiovisual alarm levels for low or high heart rate Operates from mains voltage or from internal rechargeable battery yes - Power consumption - - weight - - Power cable length (meter) 3 METER OR MORE - Display must allow easy viewing in all yes - 2/4 ambient light levels Audiovisual alarms required: high and low heart rate; operator variable settings, cardiac arrhythmia, sensor/wire disconnected, low battery yes - STANDARDS AND SAFETY, CERTIFICATIONS Certification(s) CE Approved product - MISCLANEOUS Warranty (years) 3 3, 5 Higher is better power input and frequency 220 To 240V, 50 Hz AC - Certificate of Calibration and Inspection to be provided YES - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Nishi Kant Sarkhel 500011, Air Force Station Begumpet Bowenpally Secunderabad 1 15
acute care monitoring units and related products- patient monitors Acute Care Monitoring Units And Related Products-patient Monitors ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values NEW SET Type of Monitor Preconfigured/Non Modular - Functional Requirements: Operates from mains voltage or from internal rechargeable battery Operator can set audio visual alarm levels for low or high levels of each parameter independently Allows display of single, 3 lead ECG or simultaneous display of at least 5 waves ECG selected from up to 12 points Display to be digital of all active parameters and trace display for at least three selectable parameters Yes - Clinical Purpose: Designed to continuously measure and display multiple vital physiological YES - 1/7 parameters of adults, newborn and premature infants, especially those under critical care Continuous display on screen of neonatal or infant ECG, respiration and heart rates, invasive/non-invasive blood pressure, body temperature and SpO2 Yes - Patient monitor offered with option to monitor parameter(s): EtCO2, IBP, Cardiac Output EtCO2, Cardiac Output Number of leads for ECG 5 3, 5, 12 Screen Size 12 8, 12, 14, 15, 17 Weight 5 - ECG patient connectors that are sterilisable and reusable are acceptable though reusable cables that attach to disposable connection patches are preferred Multichannel (up to 12 leads) ECG measurement and selectable display of upto 5 leads at a time Temperature probe to be reusable, external skin contact type; Temperature range at least 30 to 40 deg C, minimum gradation (1/10) deg C/Heart rate measurement range to be at least 30 to 250 bpm, with accuracy better than ± 5 bpm and minimum gradation 1 bpm/SpO2 measurement range at least 40-70 % and 70 to 99 %, with accuracy better than ± 1% for 40-70 range and better than ± 3% for 70-99 range and minimum gradation 1%/Blood Yes - 2/7 pressure monitoring range at least 30 to 300 mmHg, minimum gradation 1 mmHg Respiration rate measurement range at least 0 to 100 bpm, minimum gradation 1 bpm/Trend display of each parameter over at least previous 24 hours to be selectable ECG patient connectors that are sterilisable and reusable are acceptable though reusable cables that attach to disposable connection patches are preferred Multichannel (up to 12 leads) ECG measurement and selectable display of upto 5 leads at a time Temperature probe to be reusable, with accuracy better than ± 1% for 40-70 range and better than ± 3% for 70-99 range and minimum gradation 1%/Blood pressure monitoring range at least 30 to 300 mmHg, minimum gradation 1 bpm/Trend display of each parameter over at least previous 24 hours true - 3/7 to be selectable/TFT Screen User Interface Manual through knob or key board Manual through knob or key board, Through touch Screen, remotely operated Audio Visual alarms high and low levels for each parameter (operator variable settings), sensor/wire probe disconnected, low battery - Case is to be hard and splash proof/Display must allow easy viewing in all ambient light levels/Cable connectors to be designed so as fit correct socket only Yes - Noise (in dB) < 50 - Heat Dissipation: Should maitain nominal Temp and the heat should be disbursed through adequate arrangement - Mobility & Portability mobile and portable in protective case supplied for clean storage and safe transport. - Power supply replaceable and rechargeable Battery Operated (Min one hour operation support in the event of power failure) 220 volt, 50 Hz AC, replaceable and rechargeable Battery Operated (Min one hour operation support in the event of power failure), Replaceable And Rechargeable Battery Operated (Min One Hour Operation Support In The Event Of Power Failure) and 220 Volt, 50 Hz AC both Mains cable to be at least 3m length YES - Accessories & Spare Parts: pairs of ECG cable 5 sets of ECG connection electrodes 1 unit each of reusable SPO2 probe(Adult/Paediatric) 1 unit of SPO2 probe(Neo natal) 2 pairs of ECG cable 5 sets of ECG connection electrodes 1 unit each of reusable SPO2 probe(Adult/Paediatric) 1 unit of SPO2 probe(Neo natal) 2 4/7 units of NIBP cuffs for adult 2 units of NIBP cuffs for Paediatric 1 unit each of skin and rectal Temperature probe units of NIBP cuffs for adult 2 units of NIBP cuffs for Paediatric 1 unit each of skin and rectal Temperature probe Operating condition: apable of operating continuously in ambient temperature of 0 to 50 deg C and relative humidity of 15 to 90% in ideal circumstances - Should be FDA CE/BIS approved product European CE US FDA, European CE, BIS - Electrical safety conforms to standards for electrical safety IEC-60601-1/- Shall meet IEC-60601-1-2 (General requirements for safety - electromagnetic compatibility)/-Also conforms to IEC 60601-2- 27 (Particular requirements for the safety of electrocardiographic monitoring equipment) - Manufacturer supplier should have ISO certificate for quality standard/- Shall meet IEC 60601-2-49 multi function patient monitoring equipment standard requirement Yes - Seller to perform supply, installation, safety & operation checks and training before handover of the product [Training of users in operation and basic maintenance shall be provided] Yes - Warranty Comprehensive warranty of 3 years with free servicing ( min 3/year) during warranty - 5/7 Operating manuals, service manuals, other manuals/documents Advanced maintenance tasks required shall be documented User, technical and maintenance manuals to be supplied in English language. List to be provided of equipment and procedures required for local calibration and routine maintenance List to be provided of important spares and accessories, with their part numbers. Certificate of calibration and inspection to be provided. - Recommendations or warnings Any recommendations for best use and supplimentary warning for safety to be declared - Details of Item and test reports Availability of Test Report from Central Govt/NABL/ILAC/Any OPCW accredited lab to prove conformity to specification No - Test report (if indicated as available) to be furnished to buyer on demand YES - Test report No & date NA - Name and address of the Lab: NA - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Nishi Kant Sarkhel 500011, Air Force Station Begumpet Bowenpally Secunderabad 1 15