Loading…
Loading…
20,606 results • Latest
A)Repairing and overhauling of (02 Nos.) Vertical Pump 361-T in Hydro Cyclone Section and (B) Repairing and overhauling of (03 Nos.) Submersible Pump 5 H.P with motor in Hydro Cyclone Section of Kathara Washery
Repairing and thorough overhauling of Gear Box GS-l4 and repairing of its base and supporting structure including changing of new sprocket of Unit No. 269 belt conveyor and (II) Repairing and thorough overhauling of Gear Box GS 14 A and repairing of
(A)Dismantling of tail drum and head drum size 950x500x10 mm, repairing and installation including repairing of its supporting structure of Unit No. 424 at 4.8 mtr level and (B) Dismantling of head drum and tail drum size 950 x 500 x 10mm, repairing
Dismantling, repairing and replacement of outer lining plate, top channel collar with stripner plate of dilated media tank of dimension dia 4.5mtr, conical length 3.5mtr., cylindrical length-Imtr. of Sec-1 in HMS Section of Kathara Washery
Repair, fabrication and erection of old, worn-out and damaged delivery pipe line from return water to 27 meter level in Hydro Cyclone Section of Kathara Washery
Plantation Service - Bamboo Plantation with 3 (Three) Years Maintenance on Existing Old OB Dumps of Tirap OCP
Engagement of tractor mounted water tanker supply of drinking water at Chota khadahra, Dumaria for the period of 365 days under Rajmahal Area.
Engagement of tractor mounted water tanker for supplying of water at Hijukita rehab site for the construction purpose for Basdiha village rehabilitation for the period of 365 days under Rajmahal Area..
(A) Partial repairing of 250 KVA, 11KV/440V, NGEF make transformer of RHB Sl.No 200022165 and (B) wiring and providing and fitting of LED flood light Sri Vivekanand statue at Nehru Chowk, Harina under, Barora Area.
Shifting of 4000GPM pump motor set after and before extraction of coal from the floor of Jarlahi coal face and diversion of its pipe line in safe/suitable route due to safety purpose at Phularitand, AMP Colliery.
Complete repairing of 800Amps, ABC make switch type NFLP ACB, 550Volts, Sl.No.ACB-366 for controlling of Vasuri Colony and Hatia site of Muraidih Colony of Muraidih, AMP Colliery.
Repairing of pull cord safety system of conveyor belt of F/Breaker No 4 and 5 of AMP Colliery, Barora Area.
Maintenance of chemical earth pit through repairing, overhauling and fitting required chemical materials RHB Boosting and Area office of Barora Area.
Repairing of damaged water tank utilized for water supply and sprinkling of all roads KKC Link siding under Barora Area.
A) Repairing of 400A OCB switch type K-3, 440V, GEC make Sl. No. 30/0234 for controlling of submersible starter and B) Repairing of 400KVA, 11KV/440V Lighting Transformer, Sl.No. ETS-1167/1 of Fire Area Damoda Workshop at Damoda Colliery.
Custom Bid for Services - Electrical wiring of five nos quarters of AHQ colony Nagpur Area Similar Category Operation And Maintenance Of Electro-Mechanical Installations
Repairing and construction of culvert over the diversion of existing drain by mining contract for the movement of coal transportation over diverted drain under Sharda OCM of Sohagpur Area
Facility Management Services - LumpSum Based - SECL GEVRA AREA; Deployment of 03 Nos Vehicle Mounted Silent DG Sets (15 KVA Rating) at Quarry mines premises for day to day E&M related work for a period of 365 Days at Gevra Project; Cost of consumable..
Providing with fixing of GOAB switch and lightning arrestor for 11th Pit Sub Station under Rampur Sub Area under Orient Area
Water Purification System with UV (Ultra-Violet Process) or UV (Ultra-Violet Process)+UF (Ultra-Filtration Process) (V2) (Q2) MSE Relaxation for Years Of Experience and Turnover Yes | Complete Startup Relaxation for Years Of Experience and Turnover Yes | Complete
Split Air Conditioner Including Green AC, Wall Mount Type (V2) (Q2), Split Air Conditioner (Floor Type), as per IS: 1391 (part 2) (Q2) MSE Relaxation for Years Of Experience Yes | Complete Startup Relaxation for Years Of Experience Yes | Complete Document required from seller Certificate (Requested in ATC), OEM Authorization Certificate, Additional Doc 1 (Requested in ATC), Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience Turnover Criteria, the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer ? ? Do you want to show documents uploaded by bidders to all bidders participated in bid? Yes (Documents submitted as part of a clarification or representation during the tender/bid process will also be displayed to other participated bidders after log in) Minimum number of bids required to disable automatic bid extension 3, -- Number of days for which Bid would be auto -- extended 7 Bid Number : GEM/2025/B/6976902 Dated : 16-01-2026 Bid Document 1/13 Number of Auto Extension count 1 Bid to RA enabled No Type of Bid Two Packet Bid Primary product category Split Air Conditioner Including Green AC, Wall Mount Type (V2) Time allowed for Technical Clarifications during technical evaluation 7 Days ( )/Inspection Required (By Empanelled Inspection Authority/Agencies pre-registered with GeM) No Estimated Bid Value 1276494.56 Evaluation Method Item wise evaluation Arbitration Clause No Mediation Clause No Bid Details EMD Detail Advisory Bank State Bank of India Schedule 1 EMD Amount (In INR) 4000 Schedule 2 EMD Amount (In INR) 20000 Schedule 3 EMD Amount (In INR) 3000 ePBG Detail Advisory Bank State Bank of India (%) ePBG Percentage(%) 5.00 ( ) Duration of ePBG required (Months). 4 (a). EMD EXEMPTION: The bidder seeking EMD exemption, must submit the valid supporting document for the relevant category as per GeM GTC with the bid. Under MSE category, only manufacturers for goods and Service Providers for Services are eligible for exemption from EMD. Traders are excluded from the purview of this Policy. 2/13 (b). The EMD Amount will be applicable for each schedule/group selected during Bid creation. (c)., EMD & Performance securityshould be in favour of Beneficiary, wherever it is applicable. Beneficiary : SECL, DIPKA AREA SECL DIPKA AREA, AREA GM OFFICE, MATERIALS MANAGEMENT WING, KORBA DISTRICT, CHATTISGARH- 495452 (Secl Dipka Area)
Steel Almirah/Cabinets (V4), PROCUREMENT OF DINNING TABLE WITH GRANITE TOP, PROCUREMENT OF DINNING CHAIR, Waiting Area/Airport Terminal/Public Place Reception area Chair or Seat (V2)
Repairing and Maintenance of Central Air Conditioning units installed at Belpahar Training Institute(BTI), Lakhanpur Area, MCL
Complete rewinding and repairing of 250KVA,11KV/440V NEI make transformer of Boosting substaion of Barora Area.
Diversion and dismantling of LT 440 V, OHL at Sukhupatnayak chowk, Lakhanpur Area, for Construction of New Overbridge at Sukhopatnayak Chowk, Lakhanpur Area, MCL
New electrical wiring of Qtr No.C-42,Qtr No.C-23 and Qtr No C-151 of Harina Colony under Barora Area.
Dry Laser Imaging Film Size-14x17 Inch ( 10 packet ), DRY LASER IMAGING FILM SIZE- 8X10IN ( 35 packet ), DRY LASER IMAGING FILM, SIZE- 12x10IN ( 35 packet )
Annual maintenance of Garden in front of Project Office at ILBL OCP of Lakhanpur Area. (For 730 Days).
SCREW, 180LPS, 170M, PART NO.FM590BD2402104531032, BALANCE VALVE, 170M HEAD, PART NO.FM590BD2402104531033, DOWEL PIN BAL VALVE CVR, PART NO.FM590BD2402104531034, IMP. KEY, EN-8, PART NO.FM590BD2302105062035, SHAFT SLEEVE NDE, BRONZE, 3-STG, PART NO.FM590BD2302105062037, SLEEVE NUT NDE, 3- STG, PART NO.FM590BD2302105062038, OIL SIGHT WINDOW ASSY., STEEL AND GLASS, PART NO.FM590BD2302105062043, BEARING BUSH DE AND NDE, PART NO.FM590BD2302105062044, DOWEL PIN BRG. CAP BRG. BODY, EN-8 EN-9, PART NO.FM590BD2302105062050, GASKET BRG. CAP BRG. BODY, PART NO.FM590BD2302105062051, PACKING PCS. STYLE NO.3116, PART NO.FM590BD2302105062052, DOWEL PIN, EN-8 EN- 9, PART NO.FM590BD2302105062053, SLEEVE NUT DE, PART NO.FM590BD2302105062059, WATER SLINGER, RUBBER, PART NO.FM590BD2302105062060, BALANCING WATER CONN.LINE ASSY, MS, PART NO.FM590BD2302105062061, WATER SEAL TUBE, FLEXIBLE, 3-STAGE, PART NO.FM590BD2302105062062, CINCH FITTING, STEEL, PART NO.FM590BD2302105062063, FLEXIBLE COUPLING, TYRE, 120LPS, PART NO.590BD201048036070, BEARING BUST D.E AND N.D.E, PART NO.FM590BD23021044910-44, GASKET FOR CASING, PART NO.P5922A150622203036, BUSH INTER STAGE, CF-8, PART NO.P5922A170128437035, COLLAR INTER STAGE, PART NO.P5922A170128437034, STUD BOLT WITH NUT CASING TO GLAND, PART NO.P5922A170128437028, PUMP SHAFT, EN8, PART NO.P5922A170128437026, BRG. HOUSING BRACKET D.E., PART NO.P5922A170128437025, WATER SEAL RING, PART NO.P5922A170128437021, STUFFING BOX BUSH, PART NO.P5922A170128437020, SHAFT SLEEVE, PART NO.P5922A170128437019, KEY FOR IMPELLER, PART NO.P5922A170128437017, PART NO.P5922A170128437013, PART NO.P5922A170128437012, WEARING RING CASING, PART NO.P5922A170128437011, SLEEVE NUT N.D.E., PART NO.P5922A170128437009, BEARING COVER D.E. AND N.D.E., PART NO.P5922A170128437006, SHAFT COLLAR, PART NO.P5922A170128437005, LOCK WASHER FOR BEARING, PART NO.P5922A170128437003, LOCK NUT FOR BEARING, PART NO.P5922A170128437002, BRG. HOUSING BRACKET N.D.E., PART NO.P5922A170128437001, ROTATING ASSEMBLY FOR FLOWMORE MAKE PUMP, PART NO.RAP5922284370, STUFFING BOX COVER D.E. AND N.D.E, PART NO.5922201048034049, BEARING COVER N.D.E, PART NO.5922201048034006, BRG.HOUSING BRACKET D.E, PART NO.5922201048034025, BEARING BRACKET HOUSING N.D.E, PART NO.44, BEARING BRACKET HOUSING D.E, PART NO.2, PART NO.1, COVER FOR BRG. HOUS D.E., PART NO.4, COLLER INTER STAGE, PART NO.8, PART NO.9, PART NO.17, COVER FOR BRG HOUS NDE, PART NO.28, PART NO.16 KEY (FOR PUMP HALF COUP.) EN-8, Part No.FM590BD2302105062001, PUMP SHAFT 180LPS, Part No.FM590BD2402104531002, OIL RING (DE & NDE), BRASS, Part No.FM590BD2302105062003, OIL CAP, Part No.FM590BD2302105062004, DUST COVER, ALUMINUM, Part
Dismantling and withdrawal of damaged pontoon set and installation of pontoon set after repairing along with Pump motor sets at Main Patch, AMP Colliery, Barora Area
Renovation Baroud Dispensary and its entaire Campus at Baroud OCM Area.
Diversion of existing 10 inch dia pipe range and laying through a separate route due to construction of railway line from pond to pumping site and miscellaneous repairing work in pump under Muraidih, AMP Colliery under Barora Area.
CCTV surveillance on the occasion of Final Day Function of Annual Mines Safety 2025
HOSE 4439778,PART NO-4439778, HOSE HPAA345X112X2000HOSE,PART NO-4454680, HOSE HP,PART NO-4454715, HOSE HP,PART NO-4454750, HOSE HP,PART NO-4439777
Repairing of flood light, wiring and miscellaneous electrical work in CISF camp bhimkanali of Barora Area
Complete renovation and fresh electrical wiring in AFM office of Barora Area
Handling, Transport and Other Mining Services - Percentage quote based - Assistance work in mining, crushing or screening plant, garage, workshop etc.
Supply and installation of Retro reflective sign boards at important locations (2) Radium letter writing with pasting for display of names of various switches / panels (3) Painting of various Control Panels / VCBs (4) Designing and writing of Safety
Repairing of electrical Wiring of Old Attendance Rooms and Substation at Siding and Feeder Breaker Incharge Rooms and Substation at Benidih, AMP Colliery, Barora Area.
Preservation of store materials, cleaning of store racks, spare parts and other materials and handling of material including jungle cleaning, surface dressing in R/S for period of 2 years at Amlohri Project.
Repair and Maintenance of 03 no.s RO Filter Plant with all Consumables Required for Maintenance for 2 years Complete For Chhal Sub Area and Baroud Sub Area as per the Instruction of Engineer-In-Charge
(A) preventive maintenance and dismantling, and re drawing of 440 volt,3 ph 4 wire line and (B)Dismantle supply fitting of power distribution system of No- 1 and 2 material shed and store back side of Bankola Area store under Bankola Area.
Annual Maintenance contract (AMC) for Digital water flowmeter with telemetry installed in different collieries under Barora Area.
Regular maintenance of water supply pipe line, Plumbing works and minor repair of buildings works as and when required at Balram OCP under Hingula Area (For a Period of 02 Years).
Annual Maintenance Contract and repairing of 2000 nos. of CI test weights of 20 kg each, for stamping of KKC Link-1 and II Road Weigh-bridges (capacity 60 T) of Barora Area.
Providing Permanent Shed for Protection of New D.G. set in colony Substation Baroud Sub Area, Raigarh Area.
USB Type External Hard Disk Drive (V2) (Q3)
Maintenance work in substation, painting of transformer, switches and other parts, slogan writing for safety purpose at siding substation under Phularitand, AMP Colliery under Barora Area.