Loading…
Loading…
31 results • Latest
Supply of Spare parts of Deep Well Hand Pumps India Mark-II under D W and S Division No. 02 Dumka for the year 2025-26.
Name of Materials
Construction of 12 nos Rural Water Supply Scheme with 1.0 HP DC solar motor pump set with 10 house connection with existing source of water, steel structure, HDPE water Tank through head of 15th finance ZPDP West singhbhum Chaibasa
Solar Photovoltaic (SPV) solar submersible D.C. water motor complete set. Desisgning, supplying, installation, testing & commissioning with all tools & parts of following solar photovoltaic (SPV) solar submersible D.C. Water Motor pump suitable for minimum 125mm x 115mm bore well as per MNRE guideling with following specifictions & accessories. (A) SPV arrays contains specified no of same capacity type & specification modules connected to series or parrallel to obtained the required voltage & current the power output of individual PV modules should be minimum 200 watt peak. (i) The SPV modules should be as per IEC-61215 and IEC 61730 part1.0 . (ii) All external prts of motor pump used in submersible pump which are in contact of water is stainless steel garde 303 or higher as required. (iii) The PV module should be mounted on metalic structure of adequate strenght and appropriate design which can withstand load of modules & High wind pressure up to 200 Km/h. (iv) The moudle mounting structure should be hot dip galvanized according to IS 4759. (v) To enhance the performance of SPV water pumping suytem & arrangement for seassonal tilt angle adjustment should be provided. (vi) Necessary arrangement shold be provided in controller automatic start-run-stop through out the day with water level detection system. (As per MNRE specification). (vii) Necessary protectin such as lightening arrestor etc. should be provided to protect the controller & SPV. (viii) The suction/delivery pipe shall be UPVC/HDPE pipes of appropriate size 60m or more as required minimum pressure rating of 8kg/Sq cm-PE 100 grade for pump up to 3HP & 10 Kg/Sq cm-PE 100 grade for 5 HP. (ix) All cable used shall be as per IS 694. Suitable size of cable shall be used in sufficient lenght for inter connection between the SPV array to SPV controller and SPV controller to solar power pump. Provision of cable shall be as per IS 14536. (x) The motor pump set should have 5 years warranty. (xi) control panel suitable for motor pump with arrangement of dry run & over flow protection sensor, float switch & rain prevention box (as per MNRE specification). (xii) The SPV controller must have IP-65 protection or must be housed in cabinet having at least IP-65 protection. (xiii) The system should be as per MNRE guide ling & Eco-friendly with suitable arrangment to operate new pump manually. (xiv) With third party inspection before dispatch. (xv) Fitting, fixing & mounting on water tank steel structure. (xvi) Provision for web based remote monitoring of the pumps to be installed must be made through the inbuilt controllers. It should be possible to ascertain the daily water output, the power generated by PV array, the Up and down time of the pump during the year, number of days the pump was unused or under breakdown repairs. The following details should be marked indelibly on the motor pump set - (a) Name of Manufacturer of distinctive logo. (b) Model Number. (c) Serial Number. (B) Solar submersible motor pump (SPV DC Type) (1) 1HP (DC pump) with 900 WP minimum watt P.V. panel as MNRE pump head max shut-off head up to 120 mtrs. For higher or lower head or in between various moudules output could be decided on prorates basis. (As per latest guide line of MNRE)
Consttruction of 08 nos Rural Water Supply Scheme with 1.0 HP DC solar motor pump complete set and 10 house connection with existing source of water, steel structure, HDPE water Tank through the head of 15th finance ZPDP West Singhbhum, Chaibasa
Solar Photovoltaic (SPV) solar submersible D.C. water motor complete set. Desisgning, supplying, installation, testing & commissioning with all tools & parts of following solar photovoltaic (SPV) solar submersible D.C. Water Motor pump suitable for minimum 125mm x 115mm bore well as per MNRE guideling with following specifictions & accessories. (A) SPV arrays contains specified no of same capacity type & specification modules connected to series or parrallel to obtained the required voltage & current the power output of individual PV modules should be minimum 200 watt peak. (i) The SPV modules should be as per IEC-61215 and IEC 61730 part1.0 . (ii) All external prts of motor pump used in submersible pump which are in contact of water is stainless steel garde 303 or higher as required. (iii) The PV module should be mounted on metalic structure of adequate strenght and appropriate design which can withstand load of modules & High wind pressure up to 200 Km/h. (iv) The moudle mounting structure should be hot dip galvanized according to IS 4759. (v) To enhance the performance of SPV water pumping suytem & arrangement for seassonal tilt angle adjustment should be provided. (vi) Necessary arrangement shold be provided in controller automatic start-run-stop through out the day with water level detection system. (As per MNRE specification). (vii) Necessary protectin such as lightening arrestor etc. should be provided to protect the controller & SPV. (viii) The suction/delivery pipe shall be UPVC/HDPE pipes of appropriate size 60m or more as required minimum pressure rating of 8kg/Sq cm-PE 100 grade for pump up to 3HP & 10 Kg/Sq cm-PE 100 grade for 5 HP. (ix) All cable used shall be as per IS 694. Suitable size of cable shall be used in sufficient lenght for inter connection between the SPV array to SPV controller and SPV controller to solar power pump. Provision of cable shall be as per IS 14536. (x) The motor pump set should have 5 years warranty. (xi) control panel suitable for motor pump with arrangement of dry run & over flow protection sensor, float switch & rain prevention box (as per MNRE specification). (xii) The SPV controller must have IP-65 protection or must be housed in cabinet having at least IP-65 protection. (xiii) The system should be as per MNRE guide ling & Eco-friendly with suitable arrangment to operate new pump manually. (xiv) With third party inspection before dispatch. (xv) Fitting, fixing & mounting on water tank steel structure. (xvi) Provision for web based remote monitoring of the pumps to be installed must be made through the inbuilt controllers. It should be possible to ascertain the daily water output, the power generated by PV array, the Up and down time of the pump during the year, number of days the pump was unused or under breakdown repairs. The following details should be marked indelibly on the motor pump set - (a) Name of Manufacturer of distinctive logo. (b) Model Number. (c) Serial Number. (B) Solar submersible motor pump (SPV DC Type) (1) 1HP (DC pump) with 900 WP minimum watt P.V. panel as MNRE pump head max shut-off head up to 120 mtrs. For higher or lower head or in between various moudules output could be decided on prorates basis. (As per latest guide line of MNRE)
E-Quotation for SITC of VT pump set at intake well Bhalki MVR pipe ws scheme and SITC of HSC CF pump set allied works at WTP Bhalki MVR pipe WS scheme Under D.W S Mech. Div jsr.
(A) Intake well (Raw water pumping plant)Supplying, Installation, testing and commissioning of water lubricated single or multistage, Radial/Mixed flow Vertical turbine pump(make-Kirloskar /Jyoti/WPIL / WILO Mather & platt) having discharge of 45 m³/hr against a total head of 72 meters consisting of pump bowl assemblies with dynamically balanced bronze impeller , stainless steel pump shaft , S.S. line shaft 1.5 mtr length each , 60 feet MS fabricated flanged type column assembly , strainer, non- reverse rachet coupling and discharge head etc. coupled with suitable Vertical hollow/solid shaft -IE3 energy efficient SPDP Squirrel cage induction motor (Kirloskar/ Jyoti/ CGL make) confirming to IS 12615:2011 with latest amendments having 10% more BHP than that of Pump operating on 3-PH, 50Hz, 415 ± 10%, 1450-1500 rpm with required size of ISI marked heavy duty CIDF sluice valve & CIDF NR valve , Pressure gauge, MS clamp including cost of construction of new foundation with suitable size of nut ,bolts and packings etc. all complete or as per site requirement or direction of E/I.
Construction of HYDT of 200/165 mm Dia 270 mtrs with 2HP Electric Motor Pump Complete set in Near Ambedkar Chowk for Community Toilet under Block-Maheshpur Group No-MAH 01
HYDT : Cost of drilling 200mmX165mmX 270 M avg.Deep Bore Well in all kinds of soil and rock in rural area for installation of pump bore set with Hydraulic DTH Rig machine, all complete including supplying all materials, tools, drilling rig, Air Compressor and equipments, as well as fuel, lubricants and cost of transportation of Rig machine and other vehicles up to the site.
Construction of HYDT of 200/165 mm Dia 270 mtrs High Yield Drilled Tube Well with Installation of IM-II Hand Pump, Platform and 2HP Electric Motor Pump in Near Durga Mandir Community Toilet, Block- Amrapara Group No- AMR 01
HYDT : Cost of drilling 200mmX165mmX 270 M avg.Deep Bore Well in all kinds of soil and rock in rural area for installation of pump bore set with Hydraulic DTH Rig machine, all complete including supplying all materials, tools, drilling rig, Air Compressor and equipments, as well as fuel, lubricants and cost of transportation of Rig machine and other vehicles up to the site.