Axle Mounted Disc Brake System for AC & NAC Coaches-(QR Code as per CDE/RCF Letter No. MD44121 Dt. 24.11.2021.) as per Drawing No. RDSO/2011/CG-02, Make:- Faiveley (PAC)
Surface Protection Coating For Control Arm in Packing of 5 Ltrs. Make/Brand - BLASOL 135 of M/s. Blaser Swiss Lube or CORTEC VCI-368 or Molytec EP of M/s. STANVAC Chemicals India Ltd.
Water tank 450 liters complete without water level Indicator for LHB coaches RCF's Drawing no.:- LP-63100,Alt-e, or latest. Mat spec.:- As per Drawing with latest revision and amendment.
SUPPLY AND APPLICATION 4MM OF STAROXY SL 1000 AND STAROXY 105 100% SOLIDS EPOXY COATING EPOXY FLOORING AS PER DRAWING No. 2026/03/0890. MAKE- SHERWIN- WILLIAMS OR SIMILAR.
Supply of Heavy Duty Brake Piping Arrangement in LHB Bogie consisting of Connectors & Air Pipe Accessories as per Drg. No.: LW36004, Materials supply as per Drg. & Part No., Details of Materials as follows: (1) Stand Pipe Elbow, Item No.: 19, Part No.: EVL18LOMOA3C (Qty.: 4 Nos.) (2) Progressive Ring, Item No.: 18, Part No.: DPF18LX (Qty.: 12 Nos.) (3) Union Nut, Item No.: 17, Part No.: M18LA3X (4) Male Stud Connector, Item No.: 16, Part No.: GE18LRA3DX (Qty.:4 Nos.) (5) Stand Pipe Run Tee, Item No.: 9, Part No.: EVL18LOMDA3C (Qty.: 4 Nos.) (6) Tube Pipe SS304, Item No.: 5, Part No.: LW36127
GI Male Female Elbow 15mm to IS:1239 (Part-2):1992, Table No:24
Release Valve R1/2" for air brake system used in EMU/MEMU. Escort's DRG No: 4A16014 as per Drg.No. DRG No: 4A16014
Supply and fitment of aerosol based fire suppression system in Non-AC SG Coaches. with minimum 1 No. 10 gm fire extinguisher in line with technical parameters and approved makes as per RDSO Specification no. RDSO/PE/SPEC/AC/0192-2018 (Rev) and RDSO L/No. EL/7.1.108/MSSBC/Main, Dated: 17.07.2023. All necessary modification, clamping arrangement & accessories required for installation of this item in the rotary switch panel of SG Non-AC Coaches shall be with the scope of this supplier. ELIGIBILITY CRITERIA: 1) RDSO APPROVED MAKES FOR AEROSOL FIRE DETECTION & SUPPRESSION SYSTEM OEM OR THIER AUTHORIZED DEALERS SHALL ONLY BE CONSIDERED. 2) RDSO APPROVED SOURCES FOR SBC WITH AEROSOL FIRE DETECTION & SUPPRESSION SYSTEM SHALL ALSO BE CONSIDERED.
ADJUSTING PULL ROD FOR BOGIE BRAKE TO ICF DRG NO.: emu/m-3-2-063, ALT. F FOR 700/1400 HP DEMU/DPC BOGIES.
Supply of spare parts required for Traverser Crane electrical operated as per attached annexure. Material specification : EN-9, HSN CODE- 8631. Test certificated of materials from NABL approved Laboratory required along with supply of materials.
Supply,Installation,commissioning of single Thyristor High Frequency Induction Heater of capacity 50KW for dismounting of steel tube of GM Loco(WDP4 & WDG4) with fixed Coil for each job as per Technical Specification in ANNEXURE-I Make:Invotech Engineers Pvt. Ltd.,Precision or any other suitable
Water Pressurizer Unit (With Input/output Assy. Connectors, Leg Brackets, nut bolt) For Left and Right Side Toilet as Per MMDTS 19027, Rev-03. Make-SPAC Part No. SPAC.0018975 or equivalant which must be Functionally Compatible in Pressurized Flushing System of Indian Railway Coaches Fitted with Pressurized Flushing System.
Slack less Draw Bar to Drawing No RITES/TP-9405-S/001 and to RDSO Spec. No. WD- 73-BD-SDB-20