Loading…
Loading…
9 results • Latest
Basic Automotive Tools
CHARGING STATION
BOQ (Q3) ()
Stainless Steel Bain Marie
Wet Grinder
Domestic Blenders/Dough Kneader
Potato Peeler
Multimedia Projectors ( PAC Only )
diesel generators- DG Sets Average Turn Over of Last 3 Years 2 Lakh (s) Experience with Gov. Required 2 Year (s) Diesel Generators- DG Sets ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values OUTPUT CAPACITY RATING/PHASE Nominal Rated Capacity (KVA) 25 25 (or higher) No of Phase - Single phase, Three Phase ENGINE Make of Engine - - Model Number of Engine - - Capacity of Engine (cc) - - Engine Power (kWm) - - ISI Marking to IS :10001 for engine false - BIS license No, if applicable - - Type of Engine cooling Liquid Cooled Air Cooled, Liquid Cooled Type of governer Electronic Mechanical, Electronic (or higher) Class of governer A1 A0, A1, A2 (or higher) Number of cylinders 4 - 1/4 (nos) No of Strokes (nos) 4 - Rated RPM of Engine (RPM) - 1500, 3000 Overload capacity for one hour for every 11 hours continuous running at full load (%) 10 - Specific Fuel Consumption (gm/kWh) - - Starting voltage (volt) 12 - ALTERNATOR AC GENERATOR(ALTER NATOR) Make - - AC GENERATOR(ALTER NATOR) model Number - - Rating of AC Generator (KVA) 25 - Power Factor of AC generator 0.8 - Efficiency at rated Power factor at 75% of full Load 76.73 - Compliance of Alternator to IS:13364(part-1) Yes - Type of alternator Brushless - Voltage Regulation Grade VG 3 - Alternator IP Rating IP 23 - Class of Insulation H - CONTROL PANEL Control Panel AMF AMF IP Rating of Control Panel IP 53 - ACOUSTIC ENCLOSURE Sheet Thickness 1.6 1.6, 1.8, 2, 1.2 Higher is better Thickness of Foam 25 - Density of Foam for sound insulation 28 - Noise level at 1 meter (dB) 74 - BATTERY Battery Type & Specification Normal lead acid to IS: 7372 for motor vehicles - Battery capacity (Ah) - - No of batteries 1 - 2/4 TEST REPORTS Availability of Type test report for Engine from Central govt/NABL/ILAC accredited laboratory Yes - Test Report number and date(Engine) - - Name and address of laboratory(Engine) - - Availability of Type test report for Alternator from Central government/NABL/ILAC accredited laboratory Yes - Test Report number and date(Alternator) - - Name and address of laboratory(Alternator) - - DG set meet requirements of Enviro nmental(Protection) Rules 1986, in respect of noise and emission norms, as described in STC Yes - WARRANTY INSTALLATION & COMMISSIONING Warranty 2 Installation & Commissioning With Installation With Installation Agreed to STC of the Product Yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Patel Hardikkumar 388255, model school first floor kedarnath mahadev mandir balasinor distt mahisagar Gujrat. 1 15