Loading…
Loading…
9,992 results • Latest
Balance Works of construction of yard drains, Quarter work at level crossings, Chain Link Fencing work in Forest area, Boundary wall construction at approach of Puranpur station, LHS repair for prevention of waterlogging and Cess repair at isolated locations in connection with left over works of Gauge Conversion Works in the PBE-MLN Section of IZN division.
NER-LJN Division:- Improvement of LHS No. 55/C , 60/C, 63/C, 64/C, 65/C, 69/C, 113/C and 116/C = 08 Nos. under SSE/W/STP & LHS No. 4/C, 7/C, 11/C, 31/C, 43/C ,46/C, 48/C,49/C, 50/C, 51/C, 54/C, 67/C, 80/C, 81/C and 86/C = 15 Nos. under SSE/W/BVN. (Total LHS 23 Nos.)
Provision of office for Divisional Traffic Inspector at KPV, LKU, PBE West and PBE East stations of IZN division.
Provision of Piped water supply in colony at BNSA, MJZ, NRY, SSC, STH, STH, BPZ and SKX stations by providing plastic tank over RCC stagging in IZN division.
Signalling Works in Connection with Improvement of various Station Yards under ADEN/BRK, ADEN/East/GD, ADEN/Line/LJN, ADEN/MLN, ADEN/W/GKP, ADEN/SPL/GD, ADEN/STP & SrDEN/HQ/LJN section of LJN Division of N.E. Railway.
Levothyroxine 50mcg Tab
Tenecteplase 40mg Inj
Atorvastatin 40mg Tab
Hemospot for Occult Blood Test.
POH Kit for KE Make Distributor Valve etc.
Cast Copper Alloy Screw Down Bib Taps and Stop Valves for Water Services conforming to IS 781 (Q3) MSE Relaxation for Years of Experience and Turnover No Startup Relaxation for Years of Experience and Turnover No
P.U. Paint top coat, colour-satin blue colour code-177 of IS:5/2007 (Reviewed in 2022). Two pack system, as per RDSO Spec. No. M&C/PCN/100/2018 with RDSO%u2019s amendment no. 1B (Rev. 2.0) as an Additional requirement.
Brush Paint & Varnish (Oval) Ferrule bound Size- 2/0 of vulcanized rubber set type to IS:487/2023 and Bristle to IS:1844/1993 with amendment 1 of Dec'21 as per approved sample with proper marking during bulk supply.
wist drill HSS Morse taper shank, size -7.2 mm confirming to IS:5103/1969 with Amndt. No. 3 and IS:5099/2003 with Amndt. No. 1 of Dec' 2006
Mosquito Nets (V2) Conforming to IS 9886 (Q3) MSE Relaxation for Years of Experience and Turnover No Startup Relaxation for Years of Experience and Turnover No
Cleaning of Electric Locomotives including cleaning of Radiators, Filters, Loco body, look out glass & window glass, Driver cabs, Machine room, Corridors etc. of 3- phase & conventional locomotives for a period of 24 months at Electric Loco Shed- Gonda & Washing Blowing Cleaning of Hotel Load filters during Trip schedule at trip Shed GKP &LJN.
BED SHEET COTTON BLEACHED SUPERIOR QUALITY
Supply of metal body(galv. mild steel)
Supply , fixing & Installation of LED Bollard light with low glare diffuser
Evaporative Air Coolers (Electrical)
Bolt M20x75 with Nylock (C&W Item)
MS Expansion valve (C&W Item)
Traction transformer complete with cooling system & accessories like H.T. cable along with protection shield in passenger compartment and underframe area, thermostat etc. related protection equipment and with safety chain arrangement including termination crimping lugs, cable markers with heat shrinkable sleeves for power and control cables, equipment mounting and earthing hardware and accessories as per attached specification suitable for 3 Phase MEMU (MEDHA, On- board).
CEILING CREW ROOM MOUNTING FOR LHB POWER CAR COACHES
Prepaid energy meter (Q3) MSE Relaxation for Years of Experience and Turnover No Startup Relaxation for Years of Experience and Turnover No
OHE related work for provision of 3rd loop line at Sehramau station of IZN division.
Electric Ceiling Fan (V4) ISI Marked to IS 374 (Q2) MSE Relaxation for Years of Experience and Turnover No Startup Relaxation for Years of Experience and Turnover No
INTERLOCK WASHERS
SET OF ALL TYPE HYDRAULIC SYSTEM HOSES FOR 1600HP DEMU AS PER ANNEXURE (A) ATTACHED
DUSTER KHADI CLOTH WHITE 50.8 X 45 HEMMED ON ALL SIDES TAKEN TO BE MARKED "I R" IN EACH CORNER WITH INDELIGIBLE INK SPEC. NO. IS:3777/1968. Make: KHADI INDIA
Supply, Installation, Testing and commissioning of SMPS based Integrated Power Supply (IPS) system for Station in RE area confirming to RDSO specification No. RDSO/SPN/165/2023 version 4.0 Amendment 1
Overhauling Kit for Leveling Valve consisting of 16 items (KB Make) as per list- (1) SEALING RING PART NO. B74370/2 QTY 01 (2) O RING PART NO. A27763/26 QTY. 01 (3) O RING PART NO. A75374 QTY. 01 (4)
supply and installation of UV marble sheet on wall and floor of bathroom and kitchen area of coach 013104/CE. note ( stripping of old panels and pasting of new panels with adhesive and other auxiliari
Micro Controller for Pump Confirming to RCF Specification No EDTS-186 (Rev-A) Amendment No.2, corrigendum-2 for LHB Coaches. The Make of the Micro Controller for Pump is Garz and Fricke/DR Auto/Kalsi
Ophthalmic canula SIMCO I/A regular 23G OPHTHALMIC CANULA 23G SIMCO I/A (REGULAR 23G WITH SILICON TUBING) MAKE/Brand-INDO WEBAL
Paint Enamel Synthetic Exterior finishing Golden Yellow ISC No.356 as per IS: 5/2007 (Reviwed in 2022) to IS: 8662/2024 third revision with RDSO Amendment No. 1A (Rev. 1.0) as an additional requireme
Helical Spring Centreless Ground to ICF Drg. No. MG/T-0-1 -002 Alt.x/4 confirming to RDSO Specn. No. WD-01- HLS-94 Rev.4 Matl. & specn. - IS : 3195/92 with Amndt. no.2,Grade -6oSi7. Make/Brand- Own/Se
Fire Retardant curtain fabric to RDSO specification no. C- 9911 Rev. 3 of Feb, 2005 with 6 amendment last amendment no. 6 issued in Aug. 2016 and corrigendum 1 of May 2015 Shade and Pattern for AC Coa
16 Point 24 V DC Digital Output Module,16 Point 24 DC Digital Input Module and DC/DC Power Supply.
Tamper check paste (30ML) (High visible, viscous and fluorescent.
1 inch Pneumatic Impact Wrench with following specification
Air Filter Assembly
Office items
Office Item
95 sqmm Copper Crimping Socket (LUG) L-Type ( 90 Degree Bend) Stud Size M16 as per RDSO Spec No.RDSO/PE/SPEC/AC/0177 ( Rev-1)-2013 & asper RCF DRg-LW 7/328
Hex Bolt with lock nut and washer M12x65, Make: TVS,Unbrako,DFL or equivalent .