Loading…
Loading…
81 results • Recent activity
Supply, safe delivery, testing and warranty of microwave Transmitter and Receiver pair as per the sp
16 Channel Process Scanner With Relay Output, Make- Masibus, Model-85XX+ -AIAIN- RL-N-U1-1E-NN With B, 8 Channel Process Scanner With 8 Channel Analog Output And 8 Channel Relay Output With 5 Mtrs Cable,
Safe supply and delivery of a 12Vdc, 7000 rpm, 8 CFM air low, single phase, 4-pole, brushless DC mot
Calibration Services - 1 No of Calibration of Digital Pressure Gauge Range 0 to 15 psi Make Crystal Model No XP2i at NABL accredited laboratory For detailed scope of work refer annexures; as per bid requirement; as per bid requirement; as per bid req.., Calibration Services - 2 No of Calibration of Digital Pressure Gauge Range 0 to 1 bar Make Crystal Model No XP2i at NABL accredited laboratory For detailed scope of work refer annexures; as per bid requirement; as per bid requirement; as per bid requ.., Calibration Services - 4 No of Calibration of Pressure Calibrator Range minus 2 point 5 to 2 point 5 mbar Make Druck Model No DPI 610 at NABL accredited laboratory For detailed scope of work refer annexures; as per bid requirement; as per bid require.., Calibration Services - 3 No of Calibration of Pressure Calibrator Range minus150 to 150 mbar Make Druck Model No DPI 610 at NABL accredited laboratory For detailed scope of work refer annexures; as per bid requirement; as per bid requirement; as per.., Calibration Services - 4 No of Calibration of Pressure Indicator Range minus 25 to 25 mbar Make Druck Model No DPI 610 at NABL accredited laboratory For detailed scope of work refer annexures; as per bid requirement; as per bid requirement; as per b.., Calibration Services - 3 No of Calibration of Pressure Indicator Range minus1 to 2 bar, Make GE Druck Model No PM 620 at NABL accredited laboratory For detailed scope of work refer annexures; as per bid requirement; as per bid requirement; as per bi.., Calibration Services - 2 No of Calibration of Pressure Indicator Range 0 to 35 bar Make GE Druck Model No PM 620 at NABL accredited laboratory For detailed scope of work refer annexures; as per bid requirement; as per bid requirement; as per bid req.., Calibration Services - 3 No of Calibration of Pressure Indicator Range minus1 to 20 bar Make GE Druck Model No PM 620 at NABL accredited laboratory For detailed scope of work refer annexures; as per bid requirement; as per bid requirement; as per bid.., Calibration Services - 2 No of Calibration of Pressure Indicator Range 0 to 2 bar abs Make GE Druck Model PM 620 at NABL accredited laboratory For detailed scope of work refer annexures; as per bid requirement; as per bid requirement; as per bid requ.., Calibration Services - 2 No of Calibration of Pressure Indicator Range 0 to 100 bar Make GE Druck Model No PM 620 at NABL accredited laboratory For detailed scope of work refer annexures; as per bid requirement; as per bid requirement; as per bid req.., Calibration Services - 2 No of Calibration of Pressure Indicator Range 0 to 350 bar Make GE Druck Model No PM 620 at NABL accredited laboratory For detailed scope of work refer annexures; as per bid requirement; as per bid requirement; as per bid req.., Calibration Services - 4 No of Calibration of Pressure Indicator Range minus1 to 10 bar Make GE Druck Model No PM 620 at NABL accredited laboratory For detailed scope of work refer annexures; as per bid requirement; as per bid requirement; as per bid.., Calibration Services - 1 No of Calibration of Hydraulic Dead Weight Tester Range 1 to 400 kgcm2 Make AMETEK Model No TQD 400to1C at NABL accredited laboratory For detailed scope of work refer annexures; as per bid requirement; as per bid requirement;..
Dual-output power factor transducer with display and RS- 485 communication
LED Luminaire For Road And Street Lights Conforming To IS 10322 (Part 5/Section 3) (V3) (Under BIS Scheme - II) (Q2) MSE Relaxation for Years of Experience and Turnover No Startup Relaxation for Years of Experience and Turnover No