88 live33 closing this weekmost from Rajasthan Rajya Vidut Utpadan Nigam Limited
88 results • Latest
Grinding and Polishing of Existing Kota Stone Flooring at 17.0 Mtr. TG Floor in Front of Main Control Room, CSCTPP, Chhabra
Supply and Commissioning of Workstation with 22-inch Display and Gate Pass Entry Software to be installed at Plant Security Main Gate of 3×110 MW DCCPP, Dholpur.
Annual R and M of drains at CSCTPP, Chhabra
Misc. civil works for development of existing two wheeler parking at CSCTPP Plant Gate including covering by provision of shed.
SITC work of PVC Drift Eliminator, PVC Fills, Sprinkler Nozzle, Fan with Hub Assembly for Round Bottle Type Counter Flow FRP Cooling Tower (1X500TR) of GT-ACW Pumps installed at DCCPP RRVUNL Dholpur.
Requirement of carryout the work of Borescopic Inspection of Gas Turbine 1 (Frame9E) of 330MW,DCCPP,RVUNL,Dholpur
Urgent requirement of EJ9-1N Non Metallic Expansion Joint of Gas Turbine 2 (3305x5464) including fastner (236 nos. of size M20),Rope gasket and flat (100 mm wide x 3 mm thick ) of SS409,installed at DCCPP,RVUNL,Dholpur
Annual requirement of spares for Koso make Pneumatic Actuators installed at CSCTPP, Chhabra.
Supply of foundation spring isolator (GERB-Make) for PA and FD fans of 2x600 MW Units KaTPP, Jhalawar
Supply of Fire Resistant Hydraulic Fluid FYRQUEL EHC- N for LPBP System of Unit-6 STPS, Suratgarh against SSP-98
Complete work of repairing & overhauling of two nos. of Calzoni make Hydraulic motors removed from Elecon make wagon tippler
Repairing of Noise level transmitter audio signal convertor card & power supply card from OEM M/s Veratroniks, Hyderabad.
Requirement of Ignition system spares of Gas Turbine Spark Plug Assembly, Spark Plug Flexible Ignition Lead and Ignition Exciter at DCCPP, Dholpur.
Supply of spares for 2X75 kG/HR CW Chlorination System installed at CW forabay St-II,SSTPS,Suratgarh
Online lube oil reconditioning of Ball tube Mills in STPS, Suratgarh
Supply of Air Conditioners at STPS, Suratgarh.
Offer for conducting ash audit in compliance of MoEF&CC notification dated 31.12.2021 for financial year 2025-26 for the STPS & SSCTPS, RVUN, Suratgarh.
Procurement of HIP Turbine rotor with complete blade assembly with extension shaft for main turbine of unit5&6, 2x660 MW units of CSCTPP, Chhabra
Annual maintenance contract of passenger cum goods elevator make- KONE INDIA PVT. LTD., installed in Boiler of Unit- 7&8, SSCTPS, Suratgarh
Procurement of working oil for electro hydraulic turbine control system for Unit 5and6, CSCTPP, Chhabra
Cummins make diesel engine assembly (Model: NTA-855L-BC ESN: 25337980) removed from SAN make locomotive, to the works of OEM M/s Cummins India Ltd., for complete dismantling, inspection, repairing and overhauling, including spares
Procurement of Duplex Oil Filter and Filter Element (Make- EPE Process Filters & Accumulators) for Seal Oil System of Generator of Unit7&8, SSCTPS, Suratgarh.
Procurement of jacking oil pump (Model HPG-2C) and its spares of M/s TUSHACO (Now M/s Allweiler) for TDBFP drive turbine of Unit7&8 (2X660MW), SSCTPS, Suratgarh
Requirement of spares for Chhabi make Float Cum Boost Battery Charger 24V/30A installed in Unit 1 to 2 of CTPP Chhabra
Supply and Installation of Desktop Computers at STPS-SC, RVUNL, Suratgarh
Repairing and calibration of 5 KV Insulation Resistance Tester MIC 05s1 make Sonel Instruments India Pvt Ltd of CTPP Chhabra.
Purchase of spares for KOEL make engines (Model : 4R1040) of BE-71 Hydraulic Excavators at CHP site of SSTPS, Suratgarh against TN-02/CHP
Regarding Purchase of EL-O-Matic make actuators (EL-O-Matic (INDIA) is part of the Poonawalla Group) for STPS Units through single source procurement.
Quotation for Repair of 32 Bit Embedded CPU and PLUS Power Supply Module System of U6, STPS, Suratgarh against Limited NIT TN -08(C&ampI).
Offer for AMC of OTIS make Lifts installed at TG-1 and TG-6 at SSTPS-O and M Suratgarh
Testing of EOT cranes/ lifting machine/ Hydra and Pressure vessels installed in CA, AHP and FF AREA OF ca Circle unit 1 to 4 CTPP Chhabra
Purchase case for the spares of the Forney make IDD 9000 Detectors/Scanners installed at 2X600 MW, KaTPP,RVUNL, Jhalawar
Insurance of Ambient Air Quality Monitoring Mobile van RJ-14 / GH-8604 of Chhabra Super Critical thermal power project unit 5 and 6 (2x660 MW) Chhabra for the period of one year wef 25.11.2026 to 24.11.2027
Offer requested for providing of Consultancy Services for accounting and other related matters for 1 (one) year.
Request for Selection (RfS) of Rooftop solar Power Project Developer for setting up of cumulative DC capacity of 10800 KWp Grid Connected Rooftop Solar Power Projects including Comprehensive Operation &amp Maintenance for 2 years RVUN Plant.
Setting up of 1500 MW/6000 (for 4-hour and &gt1 cycle ) MWh Standalone Battery Energy Storage Systems under Tariff Based Global Competitive Bidding in Rajasthan with/without Viability Gap Funding Support under “BOO” model.
Setting up of 250 MW/1000 MWh (for 4-hour and &gt1) cycle Standalone Battery Energy Storage Systems under Tariff Based Global Competitive Bidding in Rajasthan with/without Viability Gap Funding Support under “BOO” model.
Comprehensive Contract for Operation &amp Maintenance of 2x660 MW Suratgarh Super Critical Thermal Power Plant, Suratgarh