Loading…
Loading…
964 results • Recent activity
Facility Management Services - LumpSum Based - Industrial; Cleaning of Drain; Consumables to be provided by service provider (inclusive in contract cost)
Custom Bid for Services - Repair of 02 Nos Water purifier Similar Category Repair and Overhauling Service
HRC PT FUSE, Part no BOSSABWNA, TEST RUN SELECTOR SWITCH, Part no BOKYCSRP125B, POTENTIAL TRANSFORMER 3.3KV 500VA, Part no HTPTL1, AUX. TRANSFORMER SINGLE PHASE, Part no PTFX, 2 POLE MCB, Part no MDG0010, VACUUM CONTACTOR 3.3KV, Part no BEV006133, VACUUM INTERRUPTER, Part no BEV0053, NO NC ACTUATOR FOR FLP, Part no BOES2, BODY BOLT, Part no AL16, HT POWER FUSE 3.3KV GRADE UP TO 200A, Part no HRC200, VACUUM CONTACTOR COIL 100V DC INDIGENO, Part no BEV0049, MULTIFUCTION PILOT RELAY WITH BASE, Part no MPR4, CURRENT TRANSFORMER, Part no LAT2001005, HEATER, Part no HEAT, AMMETER 200 5 FOR VCB, Part no 130A0200SOV33, 3PH TRANSFORMER 3.3 KV 500VA, Part no HTPTL33, CURRENT TRANSFORMER FOR O L, Part no 120300515, Part no 650400, UNDER VOLTAGE RELAY 110V, Part no EUVR1, LIVE LINE INDICATION 3.3KV, Part no HL18, OVERLOAD SHORT CIRCUIT RELAY TYPE CMSMPM, Part no BOOSR, VCB CLOSING COIL, Part no 650405, VOLTMETER, Part no VMSO65, BRASS TERMINALS, Part no OBA, ON OFF ISOLATOR 100A, Part no K52P, BODY BOLTS, Part no 000100, ISOLATOR HANDLE, Part no H9, INDICATING LED, Part no LAB9LT, THERMAL OVERLOAD RELAY WITH BLOCK, Part no MC305ANA3K, CONTACTOR, Part no BO25, COVER BOLTS, Part no 000110A, Part no 000110H, FIXED CONTACT ASSEMBLY FOR ISOLATOR, Part no 050100, MOVING CONTACT ASSEMBLY FOR ISOLATOR, Part no 050200, ISOLATOR MICRO SWITCH ASSEMBLY, Part no 050500, OVERLOAD ASSEMBLY BREAKER 30A 100A, Part no 110100A, OVERLOAD COIL 100A, Part no 110102, MOVING CONTACT ASSEMBLY FOR BREAKER, Part no 110200, MOVING CONTACT FOR BREAKER, UP TO 200A, Part no 110206, SHUNT TRIP ASSLY COMPLETE, Part no 110300, SHUNT TRIP COIL, Part no 110903, NO VOLT COIL ASSY. UNDER VOLTAGE COIL AS, Part no 110400A, ROLLER ASSEMBLY ROLLER CARRIAGE AND ROLLER, Part no 110512, FIXED CONTACT ASSEMBLY FOR BREAKER, Part no 110600, INCOMING GLAND, Part no G1, GLASS FUSE WITH HOLDER, Part no BOGF, BRASS CONE AND GLAND ASSEMBLY, Part no BOBCG, OPERATING HANDLE FOR ISOLATOR, Part no H3, PUSH BUTTON WITH SPINDLE, Part no PBS, TERMINAL BUSHING WITH INSULATOR DMC INCO, Part no T55, E L R 50 750MA AND 750MA 2A, W TIME LG AND BCT, Part no ELM7DLATS80M, FIXED CONTACT FOR ISOLATOR, 200A, Part no 050103, MOVING CONTACT FOR ISSOLATOR, Part no 050202, OVERLOAD ASSEMBLY BREAKER 110A 200A, Part no 110100B, OVERLOAD COIL 200A, Part no 110103, MOVING CONTACT FINGER, Part no 110202, ROLLER ASMBLY ROLLER CRG ROLLER, FIXED CONTACT ASSMBLY FOR ISOLATOR300A, Part no 05300400, FIXED CONTACT FOR ISOLATOR 300 400A, Part no 05300103, OVERLOAD COIL 300A, Part no 110104, MOVING CONTACT ASSEMBLY FOR BREAKER 300A, Part no 110200300, MOVING CONTACT FOR BREAKER 300A, Part no 110206A, ON OFF ISOLATOR 300A, Part no K4, FIXED CONTACT ASSEMBLY FOR ISOLATOR 400A, Part no 05300100, MOVING CONTACT ASSEMBLY FOR ISOLATOR 400, Part no 05300200, OVERLOAD ASSEMBLY BREAKER 310A 400A, Part no 110100D, SHUNT TRIP ASSEMBLY COMPLETE, ARC CHUTE PILLAR, Part no 110606, MOVING CONTACT FOR BREAKER 400, Part no 110206B, FIXED CONTACT BREAKER 400A, Part no 110604B, AMMETER 400 5 FOR ACB, Part no 130AO400SOA, CURRENT TRANSFORMER FOR AMMETER, Part no, MOVING CONTACT FOR BREAKER 400A, Part no 110200400, 400A, Part no 110600B ISOLATOR 400A, Part no KIE33, CURRENT TRANSFORMER 60/5, 15VA, Part no 12060515, MAGNETIC OVERLOAD RELAY FOR PRIMARY SIDE, Part no 122M3355693P, OFF DELAY TIMMER, Part no BOTA2DT2, POTENTIAL TRANSFORMER 3.3 KV, RESET PUSH BUTTON CONTACT ELEMENT NO+NC, Part no BOES1, PUSH BUTTON ACTUATOR FOR EL RESET, Part no BOES3, TEST- OFF-RUN SELECTOR SWITCH, Part no BOSRP137B, HRC HT PT FUSE, Part no BOABWNA, INDICATING LAMP, Part no LAB9TSUHT, 3.3KV ADOPTER, Part no R32, Part no R31, DC POWER PACK, Part no DCPP, CAPACITANCE TRIP DEVICE, Part no RAPTOR, AUX. CONTACTOR, Part no MCRA022A7, ON DELAY TIMER, Part no 13530ON, ALLEN BOLT FOR LT DOOR COVER, Part no BOAL1225, OVERLOAD RELAY (MAGNETIC), Part no OLR3, CONTROL FUSE, Part no BOKUDF4, SURGE SUPPRESSOR, Part no SS33, CONTROL RELAY 110V, Part no 135110, MULTICORE BUSHINGS, Part no MCB9, DMC BUSHING WITH COPPER FLAT, Part no T6G, BRASS TERMINAL WITH DMC BUSHING, Part no T8, POTENTIAL TRANSFORMER, Part no DS, POTENTIAL TRANSFORMER 80 VA, Part no DS1, CURRENT TRANSFORMER FOR O/L 15VA, Part no 12050515, HRC POWER FUSE, Part no 138200A, Part no H10, AUXILARY RELAY 220V, Part no BOEN3R, SINGLE PHASING PREVENTER CURRENT OPERATE, Part no BOCOP20, ON/OFF/REV ISOLATOR, Part no K4R, Part no PB11PBSL, ISOLATOR ON/OFF/REV 100A, Part no K5R, Part no 000001A, EARTH LEAKAGE RELAY 50MA-750MA & 750MA-2, MAIN POWER FUSE, Part no ABWNA, MULTI PILOT RELAY, BRASS TERMINAL WITH DMC INSULATOR, Part no T16, HT BUSHING, Part no HTTA33, REVERSING ISOLATOR 3.3KV, Part no KIR33, HT HRC PT FUSE, ISOLATOR 400A, NO/NC ACTUATOR FOR FLP, HT POWER FUSE/3.3KV GRADE UP TO 200A, VACUUM CONTACTOR COIL 100V DC - INDIGENO, AMMETER 200/5 FOR VCB, 3PH TRANSFORMER 3.3 KV/500VA, CURRENT TRANSFORMER FOR O/L, ON/OFF ISOLATOR 100A
Haematology Analyzer Reagents (V2) (Q2) MSE Relaxation for Years Of Experience Yes | Complete Startup Relaxation for Years Of Experience Yes | Complete
Custom Bid for Services - Cutting, cleaning and transportation of earth, slush, muck, loose earth from road side berms and drains from KB 1, 2, 3, 5 to Satarkata Chowk including Workshop No 01 at KOCP of Kusmunda Area Similar Category Facility Management Services - LumpSum Based Hiring of Special Purpose Mining or Earth Moving Machines and Cranes (Shift Based) Hiring of Earth Moving Equipments, Material Handling Equipments and Cranes (per Hour basis)
Custom Bid for Services - CAMC of 02 Nos 100 Te Static Fully Electronic Rail Weighbridge working at Dumanhill Siding and NCPH Siding at Chirimiri Area for a period of 03 years Similar Category Customized AMC/CMC for Pre-owned Products