Loading…
Loading…
863 results • Recent activity
Custom Bid for Services - Supply of drinking water through water tanker at Jagannathpur Sub Area of Bhatgaon Area Similar Category Hiring of Water Tanker Service
Aluminium Sulphate, Non - Ferric as per IS 260 (Q3) MSE Relaxation for Years Of Experience Yes | Complete Startup Relaxation for Years Of Experience Yes | Complete
Facility Management Services - LumpSum Based - Annual upkeeping including changing of linen etc and running operation for catering at CWS House under CWS Korba; Housekeeping; Consumables to be provided by service provider (inclusive in contract cost..
72 sq mm Voltmeter 0 5 kV 110 V HT 1100, Resin Cast Moulded CT for O L 3 point 3 kV HT 600, Vacuum contactor holding coil 110 V DC HT 204, DMC Moulded 3 point 3 kV Insulator for power fuse HT 700, Auxiliary Switch for Vacuum Contactor 2 No plus 2 NC HT 205, Power HRC fuse HT 1500, 3 pole magnetic O L relay HT 900, PT 40 VA 0 8 12 V 0 110 V HT 206, Vacuum contactor rectifier Bridge HT 201, Vacuum Contactor 400 A 3 point 3 kV HT 200, Resin Cast PT 300 VA 3 3 kV 110 V 3 Phase HT 350, Resin cast moulded CBCT HT 500, Resin cast moulded CT for ammeter HT 650, Earth Leakage Relay Unit without Transformer HT 800, Resin Cast PT 750VA 3 Point 3 kV 110V 150 VA Single Phase HT 300, Copper Bus Bar 400 A Set of 3 HT 101, HT Control fuse 3 point 3 kV 2 A HT 400, Vacuum Contactor closing coil 110 V DC HT 203, Copper bus bar 300 A FS 3 001B, Auxiliary transformer 80VA Pri 500 525 550V Sec 0 8 12 0 110 V FS 3 004B, 3 Pole Magnetic Overload Relay Type Direct Acting FS 3 011, CT for Overload Relay FS 3 012, Slide lock fuses for voltmeter 15Amp FS 3 014, HRC fuse link for Control 4 Amps FS 3 018A, Auxiliary Contactor 3NO plus 1NC 110V 415V 500V FS 3 021A, Microswitch for push Button for Start stop E L Test and E L reset FS 3 025, I S Pilot Panel Intrinsically safe FS 3 027, E L Lamp holder with lamp FS 3 029, Dash Pot Oil 200 ML FS 3 037, Isolator 300A reversing FS 3 002C, Sensitive earth Leakage Relay with CBCT and PT E L Setting 50MA to 750MA with time delay 0 point 1 to 1 Sec in step of 0 point 1 sec with test and reset microswitch and connection wire FS 3 041, Copper bus bar 400 A FS 3 001C, Isolator 400A reversing FS 3 002D, Air Break Contactor 300 A FS 3 003L, Auxiliary transformer 100VA Pri 500 525 550V Sec 0 8 12 0 110 V FS 3 004D, DMC terminal for Outgoing Partition 300 Amps FS 3 009B, 4 Pole Magnetic O L Relay Type CT operated FS 3 011A, Pilot Relay 12 V DC FS 3 026, ELR 12 V AC FS 3 038, Glass Fuse with Holder FS 3 040, CBCT Ring Type FS 3 020C, HRC fuse Base and Carrier for control 20 Amp FS 3 017, Isolator 200 Amps ON OFF FS 3 002G, Air Break Contactor 185 Amps FS 3 003H, Air Break Contactor 225 Amps FS 3 003J, ELR 12V AC FS 3 038, Short Circuit HRC Fuses 25 Amps FS 2 014A, Short Circuit HRC Fuses 32 Amps FS 2 014B, Short Circuit HRC Fuses 40 Amps FS 2 014C, Short Circuit HRC Fuses 50 Amps FS 2 014D, Short Circuit HRC Fuses 63 Amps FS 2 014E, HRC fuse Base and Carrier for control 20 Amp FS 2 016, HRC fuse Link for control 2 Amp FS 2 017, HRC fuse Link for control 4 Amp FS 2 017A, HRC fuse Link for control 6 Amp FS 2 017B, Slide lock fuses for voltmeter 15Amp FS 2 013, Short Circuit HRC Fuses 16 Amps FS 2 014, HRC fuse Link for control 10 Amp FS 2 017C, Single phase preventor cop 20 PER FS 2 021, E L Lamp holder with lamp FS 2 027, Sensitive earth Leakage Relay with CBCT and PT E L Setting 50MA to 750MA with time delay 0 Point 1 to 1 Sec in step of 0 point 1 sec with test and reset microswitch and connection wire FS 2 037, Auxiliary transformer 40VA Pri 500 525 550V Sec 0 8 12 V 0 110 V FS 2 004A, Copper bus bar 100 Amps FS 2 001, Isolator 100A reversing FS 2 002, 65 sq mm Ammeter CT Operated FS 2 011, CT for Ammeter FS 2 012, Earth Leakage Relay Complete WO Transformer 1 to 75A FS 2 018, CBCT D Type FS 2 019, Micro Switch for Push Button for Start Stop E L Test and E L Reset FS 2 025, IS Pilot Panel Intrinsically safe FS 2 035
Custom Bid for Services - Wiring arrangement for newly constructed Record room and porch in Area finance office under TA(EandM), Kusmunda Area Similar Category Operation and Maintenance Of Electrical Systems/Electrical Installations
Velox GL50 Gas Testing Flame Safety Lamp incorporated with integral extinguisher non relighting type approved by D G M S Dhanbad for All Degree Gassy Mines Seams HS CODE 98010014, Velox GL7 Modified Gas Testing flame safety Lamp D G M S Dhanbad for All Degree Gassy Mines Seams HS CODE 98010014, METHANE GAS TESTING CHAMBER Velox GL7 Gas Testing Flame Safety Lamp HS CODE 98010014, Gasket a packet contains of 100 Nos, Wick a roll contains of 13 mtr, Fixed Filament Unit modified 67A, Inner Gauge 15A, Outer Gauge 10A, Tool Kit for service and maintenance, Magnet Unlocker for opening the lock of lamp