Loading…
Loading…
2,336 results • Recent activity
Aluminium Sulphate, Non - Ferric as per IS 260 (Q3) MSE Relaxation for Years Of Experience Yes | Complete Startup Relaxation for Years Of Experience Yes | Complete
Facility Management Services - LumpSum Based - Annual upkeeping including changing of linen etc and running operation for catering at CWS House under CWS Korba; Housekeeping; Consumables to be provided by service provider (inclusive in contract cost..
72 sq mm Voltmeter 0 5 kV 110 V HT 1100, Resin Cast Moulded CT for O L 3 point 3 kV HT 600, Vacuum contactor holding coil 110 V DC HT 204, DMC Moulded 3 point 3 kV Insulator for power fuse HT 700, Auxiliary Switch for Vacuum Contactor 2 No plus 2 NC HT 205, Power HRC fuse HT 1500, 3 pole magnetic O L relay HT 900, PT 40 VA 0 8 12 V 0 110 V HT 206, Vacuum contactor rectifier Bridge HT 201, Vacuum Contactor 400 A 3 point 3 kV HT 200, Resin Cast PT 300 VA 3 3 kV 110 V 3 Phase HT 350, Resin cast moulded CBCT HT 500, Resin cast moulded CT for ammeter HT 650, Earth Leakage Relay Unit without Transformer HT 800, Resin Cast PT 750VA 3 Point 3 kV 110V 150 VA Single Phase HT 300, Copper Bus Bar 400 A Set of 3 HT 101, HT Control fuse 3 point 3 kV 2 A HT 400, Vacuum Contactor closing coil 110 V DC HT 203, Copper bus bar 300 A FS 3 001B, Auxiliary transformer 80VA Pri 500 525 550V Sec 0 8 12 0 110 V FS 3 004B, 3 Pole Magnetic Overload Relay Type Direct Acting FS 3 011, CT for Overload Relay FS 3 012, Slide lock fuses for voltmeter 15Amp FS 3 014, HRC fuse link for Control 4 Amps FS 3 018A, Auxiliary Contactor 3NO plus 1NC 110V 415V 500V FS 3 021A, Microswitch for push Button for Start stop E L Test and E L reset FS 3 025, I S Pilot Panel Intrinsically safe FS 3 027, E L Lamp holder with lamp FS 3 029, Dash Pot Oil 200 ML FS 3 037, Isolator 300A reversing FS 3 002C, Sensitive earth Leakage Relay with CBCT and PT E L Setting 50MA to 750MA with time delay 0 point 1 to 1 Sec in step of 0 point 1 sec with test and reset microswitch and connection wire FS 3 041, Copper bus bar 400 A FS 3 001C, Isolator 400A reversing FS 3 002D, Air Break Contactor 300 A FS 3 003L, Auxiliary transformer 100VA Pri 500 525 550V Sec 0 8 12 0 110 V FS 3 004D, DMC terminal for Outgoing Partition 300 Amps FS 3 009B, 4 Pole Magnetic O L Relay Type CT operated FS 3 011A, Pilot Relay 12 V DC FS 3 026, ELR 12 V AC FS 3 038, Glass Fuse with Holder FS 3 040, CBCT Ring Type FS 3 020C, HRC fuse Base and Carrier for control 20 Amp FS 3 017, Isolator 200 Amps ON OFF FS 3 002G, Air Break Contactor 185 Amps FS 3 003H, Air Break Contactor 225 Amps FS 3 003J, ELR 12V AC FS 3 038, Short Circuit HRC Fuses 25 Amps FS 2 014A, Short Circuit HRC Fuses 32 Amps FS 2 014B, Short Circuit HRC Fuses 40 Amps FS 2 014C, Short Circuit HRC Fuses 50 Amps FS 2 014D, Short Circuit HRC Fuses 63 Amps FS 2 014E, HRC fuse Base and Carrier for control 20 Amp FS 2 016, HRC fuse Link for control 2 Amp FS 2 017, HRC fuse Link for control 4 Amp FS 2 017A, HRC fuse Link for control 6 Amp FS 2 017B, Slide lock fuses for voltmeter 15Amp FS 2 013, Short Circuit HRC Fuses 16 Amps FS 2 014, HRC fuse Link for control 10 Amp FS 2 017C, Single phase preventor cop 20 PER FS 2 021, E L Lamp holder with lamp FS 2 027, Sensitive earth Leakage Relay with CBCT and PT E L Setting 50MA to 750MA with time delay 0 Point 1 to 1 Sec in step of 0 point 1 sec with test and reset microswitch and connection wire FS 2 037, Auxiliary transformer 40VA Pri 500 525 550V Sec 0 8 12 V 0 110 V FS 2 004A, Copper bus bar 100 Amps FS 2 001, Isolator 100A reversing FS 2 002, 65 sq mm Ammeter CT Operated FS 2 011, CT for Ammeter FS 2 012, Earth Leakage Relay Complete WO Transformer 1 to 75A FS 2 018, CBCT D Type FS 2 019, Micro Switch for Push Button for Start Stop E L Test and E L Reset FS 2 025, IS Pilot Panel Intrinsically safe FS 2 035
Custom Bid for Services - Wiring arrangement for newly constructed Record room and porch in Area finance office under TA(EandM), Kusmunda Area Similar Category Operation and Maintenance Of Electrical Systems/Electrical Installations
General up-keeping and maintenance of VVIP Guest House at Amarkantak under Sohagpur Area (For Two Years)
Velox GL50 Gas Testing Flame Safety Lamp incorporated with integral extinguisher non relighting type approved by D G M S Dhanbad for All Degree Gassy Mines Seams HS CODE 98010014, Velox GL7 Modified Gas Testing flame safety Lamp D G M S Dhanbad for All Degree Gassy Mines Seams HS CODE 98010014, METHANE GAS TESTING CHAMBER Velox GL7 Gas Testing Flame Safety Lamp HS CODE 98010014, Gasket a packet contains of 100 Nos, Wick a roll contains of 13 mtr, Fixed Filament Unit modified 67A, Inner Gauge 15A, Outer Gauge 10A, Tool Kit for service and maintenance, Magnet Unlocker for opening the lock of lamp