Loading…
Loading…
10,277 results • Latest
Double rotary lock lift
SUPPLY DISPLAY LED AS PER JK EXIM PART NO JK-FSD-1127 or equivalent, FIRE/SMOKE DETECTION WITH ALARM SYSTEM AS PER RDSO SPECIFICATION NO RDSO/2008/CG-04, REV- 06 NOTE: Offers from other manufacturers are acceptable, subject to meeting the required specifications and ensuring complete interchangeability and compatibility with the existing JK Exim FSDS System
12 MM Pipe as per JK-FDSS-1215 or equivalent, suitable for fitment in the FDSS system of JK Exim make. as per specification RDSO/2013/CG-06 Rev.02. NOTE: Offers from other manufacturers are acceptable, subject to meeting the required specifications and ensuring complete interchangeability and compatibility with the existing JK Exim make FDSS system.
Action Flasher Light for Automatic Smoke/Fire Detection System in LHB Coaches-Part NoJK-FSFD-1143 or equivalent, suitable for fitment in the FSDS system of JK Exim make. as per specification RDSO/2008/CG-04 Rev.06 for AC coaches. NOTE: Offers from other manufacturers are acceptable, subject to meeting the required specifications and ensuring complete interchangeability and compatibility with the existing JK Exim make FSDS system.
Pipe Tee Connector as per JK Exim part No.JK-FDS-1108, or equivalent, suitable for fitment in the FSDS system of JK Exim make. as per specification RDSO/2008/CG-04 Rev.06 for AC coaches. NOTE: Offers from other manufacturers are acceptable, subject to meeting the required specifications and ensuring complete interchangeability and compatibility with the existing JK Exim make FSDS system.
Equalising lever complete
G Union Coupling J K Exim part no. JK-FDSS-1219 or equivalent, suitable for fitment in the FDSS system of JK Exim make. as per specification RDSO/2013/CG-06 Rev.02. NOTE: Offers from other manufacturers are acceptable, subject to meeting the required specifications and ensuring complete interchangeability and compatibility with the existing JK Exim make FDSS system
Ferrule J K Exim part no. JK-FDSS-1223 or equivalent, suitable for fitment in the FDSS system of JK Exim make. as per specification RDSO/2013/CG-06 Rev.02. NOTE: Offers from other manufacturers are acceptable, subject to meeting the required specifications and ensuring complete interchangeability and compatibility with the existing JK Exim make FDSS system
Elbow, conforming to JK Exim Part No. JK-FDS-1106, or equivalent, suitable for fitment in the FSDS system of JK Exim make as per specification RDSO/2008/CG-04 Rev.06 for AC coaches. NOTE: Offers from other manufacturers are acceptable, subject to meeting the required specifications and ensuring complete interchangeability and compatibility with the existing JK Exim make FSDS system.
Flange as per JK Exim part No. JK-FDS-1107, or equivalent, suitable for fitment in the FSDS system of JK Exim make as per specification RDSO/2008/CG-04 Rev.06 for AC coaches. NOTE: Offers from other manufacturers are acceptable, subject to meeting the required specifications and ensuring complete interchangeability and compatibility with the existing JK Exim make FSDS system.
Supply of DC/DC Convertor (110V to 24V DC) Part No.JK-FSD-1120 OR Equivalent for JK EXIM Make Fire Detection (FDS). As per RDSO specification No.RDSO/2008/CG-04 REV-06
Air Filter Cartridge of part no. JK-FSD-1131 or equivalent, suitable for fitment in the FSDS system of JK Exim make. as per specification RDSO/2008/CG-04 Rev.06 for AC coaches. NOTE: Offers from other manufacturers are acceptable, subject to meeting the required specifications and ensuring complete interchangeability and compatibility with the existing JK Exim make FSDS system.
Sampling Point Cover as per JK Exim part No. JK-FDS-1110 or equivalent, suitable for fitment in the FSDS system of JK Exim make. as per specification RDSO/2008/CG-04 Rev.06 for AC coaches. NOTE: Offers from other manufacturers are acceptable, subject to meeting the required specifications and ensuring complete interchangeability and compatibility with the existing JK Exim make FSDS system.
SOLID CO2 WELDING FILLER WIRE.
Taper Plug Gauge for 6FRA6068 type TM as per RDSO DRAWING NO. SKEL-5032 ALT- 0 OR LATEST. During Delivery of material , Calibration certificate issued from NABL/ GOVT. approved test Lab. MAKE: PRASAD / PIE / GANAPATHY or equivalent
Gauge for inner labyrinth measurement on shaft as per CLW drawing no 3TJF.096.040 for 6FRA6060 traction motor.
Ring Gauge for Pinion of WAP-7 Locos. reference RDSO Drawing no: - SKEL-5043 Alt. 0 along with calibration certificate. Note: - Supply of ring gauge with the following items (1) Pulling Extractor for easy removal of ring gauge from shaft pinion (2) Gauge (GO & NO GO) size: - 15.0mm (+/- 0.30) with calibration certificate.
RJ 45 connector.
Set of Berth Number Plate with Braille Script for LHB ACCN Coaches
Hydraulic Re-Railing Equipment
305mm Single bevel Meter SAW
COACH SET OF SEATS AND BERTHS
Helmet Mounted LED Lightor Helmet Partsor Accessories (Q3)
Custom Bid for Services - OPERATION, SWITCHING & MAINTENANCE OF SUB-STATIONS OVER BANGALORE DIVISION FOR ONE YEAR Similar Category Operation And Maintenance Of Substation
Monthly Basis Cab & Taxi Hiring Services - Sedan; 1200 km x 208 hours; Local
Plain Copier Paper (V3) ISIMarkedto IS14490 (Q4)
Breath Analyser (Q3)
SW-I HAS- Construction of New Barrack for RPF Male staff SW-II Hassan- Construction of New building for RPF Post including Mahila Barrack
Upgradation of Kanivehalli and Biselehalli halts on par with NSG-6 category, in view of conversion into Block station. SW-I: Rising of PF No.1 to HL PF duly surfacing with cement concrete at KNVH Station. SW-I-(a) : Provision of Pale Fencing for 420m at PF1 SW-II: Rising of PF No. 2 to HL PF duly surfacing with cement concrete for both PF -1 & 2 at BLHI Station.
Integral Overcurrent Protection ISIMarked To IS12640 (Part2) (Q2)
PERMETHRIN 5% OF NOT LESS THAN 50 ML LOTION.
Centre pivot bottom (modified) to Drg. No. WD 85079-S/2 alt.28 Spec:
AMBROXOL 7.5MG/ML DROPS 15 ML
Bolster Coil Spring (Outer) & Bolster coil spring inner
PLNO.18300406-Resistor PRG to EMD Part No. 8318101
Rotary Switch configuration as per Specn. No. CLW/ES/3/0068 Alt. C
Roof Line insulator CAT.NO.P/1/0141a C & D No. T016/559
TRIPLE LUMEN CATHETER KIT 12FR (4.0 MM) X 16 CM