Loading…
Loading…
0 results • Latest
No matching tenders
Try removing a filter to broaden results
This organisation has published 2 tenders in the past.
View results and past tenders →New tenders appear here as soon as they are published. Until then, here are the most recent tenders and results from Works Department Zilla Parishad Beed.
High Mast Pole with LED Flood Lighting System Experience with Gov. Required 3 Year (s) High Mast Pole With LED Flood Lighting System ( 292 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Highmast with LED Luminaires contains High mast pole, LED flood light luminaire, Distribution box, MCB, Power cable, Wiring, Earthing road and wire, Mounting brackets and other suitable accessories as applicable Yes * Installation and commissioning (Installation and commissioning work at multiple locations shall follow as per the guidelines of State/Central Govt., rules and regulations as Yes. Including Civil work at site Yes. Including Civil work at site, Yes. Excluding Civil work, No 1/10 applicable Onsite warranty (in Years) 2 2, 3, 5 POLE Tubular steel poles shall be conforming to IS 2713/80(Part-1& 2) with amdt No-1 latest * ISI Marked No Yes, No ISI Marekd if "Yes" BIS License Number (CM/L Number) - Must declare (If No write NA) - * Length of Tubular steel poles (in Metre) 10 7, 7.5, 8, 8.5, 9, 9.5, 10, 11, 12 Type of steel poles Swaged (SP) Swaged (SP) Designation of Tubular steel poles as per table 2 of IS 2713/80 Part-2 with amdt No 1 410SP-48 * Earthing arrangement as per Cl.14.1 of IS:2713:1980 Part 1 latest Yes Yes, Yes Coating on the tubular steel poles (for entire length) Galvanised min. Mass of Zinc coating 360 Gms. sq. Mtr., Galvanised min. Mass of Zinc coating 360 Gms. sq. Mtr., Bitumen coated as per clause 13.1 of IS:2713 part 1/1980 Grade of steel tube, as per IS:1161/1998 Yst 240 Yst 240, Yst 310 Availability of Type Test Reports of the product from Central Govt/NABL/ILAC accredited Lab showing compliance to the specification (as per IS:2713:1980 Part 1, Part 2 latest). Yes * LED FLOOD LIGHT LUMINAIRE No. of Luminaires per pole 4 Nos./pole 4 Nos./pole LED Luminaire conformity to IS:10322/Part 5/Section 5/2012 latest and IS: 16107 (Part 2/Sec 1):2012 latest Yes * Photo biological safety Yes * 2/10 of LEDs used shall be as per IS:16108/2012 (exempt group) Types of LED Luminaire as per the IS: 16107(Part-2 Sec.-1)/2012 Type B * Types of LED Modules as per the IS: 16103(Part-2)/2012 Type 3 * LED Rating/System Wattage/Rated Power 120W * Luminaire System Efficacy (Lumen/watt) >/= 100 Lm/Watt * Ingress Protection (IP Rating) as per IS:10322 (Part 1):1982 latest IP65 IP65, IP66, IP67 Mounting brackets (included) Adjustable * Input operating Voltage range and frequency 140 to 270 V olts AC at 50 Hz+/-2 Hz with auto cutt off at below 120V 90 to 300 V olts AC at 50 Hz+/-2 Hz, 140 to 270 V olts AC at 50 Hz+/-2 Hz with auto cutt off at below 120V Automatic Higher Cut off voltage above 300 volt Yes * Rated voltage 230 V AC 50 Hz * AC Power Factor at full load ≥ 0.95 * Driver Efficiency (in %age) ≥85 * Total Harmonics Distortion (in %age) ≤ 10 * The total circuit power shall not be more than 110 percent of the value declared by the manufacturer" Yes * LED chip Efficacy ≥130 Lm/Watt * Colour temperature (+/-500K) 6000K 6000K, 5000 K Working life for LED (Minimum 50, 000 burning hours as per LM-80 report) Yes * 3/10 Colour Rendering Index(CRI) ≥70 * Beam Angle ≥120 * Optic lense materal (UV stabilised) (Write NA for without optic lense supply) NA Poly carbonate lense, NA Heat sink should be die- cast aluminium along with sufficient heat sink fins to dissipate heat effectively Yes * Capacitor shall be rated for a temperature of 105 deg. celsius or better Yes * Junction temperature * Operating temperature range -10 deg C to +50 deg C, 20 deg C to +50 deg C, 10 deg C to +50 deg C, 10 deg C to +55 deg C Operating Humidity Range 10 % to 95% RH * Short circuit Protection Yes * Over load protecton Yes * Over Voltage protection Yes * Reverse polarity Yes * High voltage test (1.5 KV for one minute between supply terminals and body of the unit) Yes * Insulation resistance between earth and current carrying part >100 M ohm * The luminaire shall be protected against surges and transients ( Internal) >/=4KV >/=5KV, >/=4KV The luminaire shall be protected against surges and transients of >/=10KV (External) Yes Yes, No The Luminaires casing/housing (single piece housing) shall be pressure die casted Yes * 4/10 aluminium alloy with higher thermal conductivity The luminaire body must be corrosion resistant epoxy powder coated Yes * All fastners must be of stainless steel Yes * The entire housing (both LED section and driver section) shall be dust and water proof having IP 66 protection as per IS:10322 (Part 1):1982 latest Yes * Extruded silicon loop gasket shall be provided in the lantern body to ensure a weather proof seal between the UV Glass cover and the metal housing to exclude the entry of the dust, water, insects etc., Yes * Luminaries light transparency should be of Toughened glass Yes * Toughned transparent glass cover thickness >/=4 mm * Toughned Glass shall not get discoloured shall not suffer degration due to heat and ageing within warranty period Yes * Number of electronic control gear per luminaire (power supplies) (in Numbers) 1 1, 2, 4 Driver components shall be industrial grade or above Yes * PCB shall be FR4 grade minimum 0.8 to 1.0 mm thick or more Yes * The Luminaires works on single phase three wires system (Phase, Neutral and Earth) Yes * 5/10 Suitable connector shall be provided for LED connection between driver output and LED Yes * Length of ISI marked three core wire (shall be provided along with supply of material) 50 cm 50 cm, 100 cm Light Source SMD LED Chip as per LM 80/IS16106 * Manufactures Name and and brand on the aluminium die cast body Engraved/Embossed * Manufacturer’s name, model number, serial number Yes * Date of manufacture (month-year), and lot number as identification mark inside each unit and the outside of each packaging box Yes * The operation characteristics voltage and power be marked inside of each LED luminaire unit Yes * LED Make OSRAM/NICHIA/CREE SAMSUNG/SEOUL LUMILED/PHILIPS EDISON/SYSKA LUMENMAX EVERLIGHT BRIDGELUX NATIONSTAR/REFOND, OSRAM/NICHIA/CREE SAMSUNG/SEOUL LUMILED/PHILIPS EDISON/SYSKA LUMENMAX EVERLIGHT BRIDGELUX NATIONSTAR/REFOND, Other than OSRAM NICHIA/CREE SAMSUNG/SEOUL LUMILED/PHILIPS EDISON/SYSKA LUMENMAX EVERLIGHT BRIDGELUX NATIONSTAR/REFOND System must have EMI/EMC compliance as applicable (Test reports shall be furnish on demand by Yes * 6/10 buyer/consignee) LM 79 (Photometry) (Ref.IS:16106:2012) report from Central Government lab/NABL/ILAC accrediated lab. Reports shall be furnish on demany by buyer (LM-79 report shall have total lumen output, power, PF, Current in Amps, CRI & CCT etc., ) Yes * LM 80 & TM 21 (Part of LM 80) (Ref. IS:16105:2012) Reports and Photo biological report for LED report from Central Government lab NABL/ILAC accrediated lab. Reports shall be furnish on demany by buyer (LM-80 report shall haveand the Pohoto Biological report of the LED Chip being used in the luminaire) Yes * Availability of test Report from Central Government lab/NABL/ILAC accrediated lab to Indian Standrad IS:10322/part 5/sec-5/2012 and IS 16107 (Part 2/Sec 1) : 2012 Yes * DC or AC supplied electronic control gear for LED Module shall comlpy as per IS:15885 (Part 2/Sec.13) Yes * LED Luminaire for Flood Light shall comply with Complusory Registration(CRS) of BIS for safety as per IS 10322 (Part 5/Section 5): 2012 as applicable on the date Yes * ACCESSORIES - G I Pipe G.I. Pipe (ISI Marked) for earthing Yes Yes, No 7/10 with all accessories per pole shall supplied G.I. Pipe length (in mm) 200 mm 200 mm, 300 mm, NA G.I. Pipe dia 40 mm 20 mm, 40 mm, NA ACCESSORIES - G I Wire ISI marked G.I. wire shall be supplied per pole for earthing Yes Yes, No G.I. wire dia (in mm) 2.64 mm 2.64 mm, NA G.I. Wire length (in m) 15 10, 15, 20, 25, 30, NA ACCESSORIES - Power Cable PVC Insulated, armoured power cable (ISI marked to IS:1554 Part 1) shall be supply per pole Yes Yes, No No. of core 2 2, NA Cross sectional area of cable (in Sq.mm) 2.5 2.5, 4, NA Conductor material Aluminium Aluminium, Copper, NA Cable category Type C, C2, FR-LSH Type C, FR-LSH, NA Length (in mtrs., ) 50 10, 50, 75, NA ACCESSORIES - Wiring PVC insulated wiring cable (IS Marked to IS:694) shall be supply per pole Yes Yes, NA Cross sectional area of cable (in Sq.mm) 1.5 1.5, NA Conductor material (for wiring) Copper Copper, Aluminium, NA Cable category (for wiring) Type C, NA Cable length (in mtrs., NA ACCESSORIES - MCB Distribution Board with Switches & Terminals and ISI marked MCB per pole shall be supply with lighting system Yes Yes, No Distribution board for fixing MCB with Yes. Provided with IP 43 Yes. Provided with IP 43, NA 8/10 enclosure protection Distribution Board per pole for fixing MCB with enclosure protection IP43 and above Yes. Provided. Yes. Provided., NA MCB - Rated current (in Ampere) 5.0 A * No. of pole 1 Pole 1 Pole, na Rated Voltage 240 Volt 240 Volt, NA Bracket for each pole : Mounting arrachement including suitable bracket for fixing the Luminaires with each pole. Bracket material shall be MS. Galvanised min. Mass of Zinc coating 360 Gms. sq. Mtr., Yes Yes, NA CERTIFICATIONS Marking: All the products shall have marking details as per relevant BIS standard Yes * Seller shall furish all the test reports and certificates as per the technical specification to the purchase auhtority on demand Yes * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Mujahid Lateef Sayyed 431122, ZP Complex PW No.2 Division, Main road Beed 292 45
Potable water purification system Experience with Gov. Required 3 Year (s) Potable Water Purification System ( 134 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values EQUIPMENT TYPE & FEATURES Type Electrically Operated Reverse Osmosis based water purifier Electrically Operated Reverse Osmosis based water purifier, Gravity operated water purifier, Water Purifier electro- deionization Based Ultraviolet (UV) LAMP Yes Yes, No Ultra Voilet (UV) Lamp power consumption 100 * STANDARDS Conformity to Indian Standrad for System IS 14724 (latest) for water purification system with Ultraviolet disinfection * Number of float valves/sensors 3 1-5 INPUT PARAMETERS Input Water TDS 4000 1000, 2000, 3000, 4000, 5000 1/4 OUTPUT PARAMETERS Recovery at 27 degree Centigrade 30-40 25-35, 30-40, 90-100, 70-80, 50-60 Output Water of RO system Conforming to Indian Standard IS 10500(latest) * Output water capacity (Litre/Hour): 750 750 Arsenic and Floride removal capability true true, false Misc, warranty etc Thin-film composite membrane Yes Yes, No, NA High Pressure Pump Yes * Raw water/Chemical Raw water/Chemical Cleaning PUMP Yes Yes, No Pre Filter Vessels: Yes Yes, No Micron Filter Yes Yes, No Membrane Housing Yes Yes, NA Auto cut Yes Yes, No No of candles (Nos) 5 1-5 Installation Type Floor mounted Table top, Wall mounted, Floor mounted, Floor mounted & enclosed Warranty period ( for free replacement of machine 2 2, 3, 1 (or higher) Warranty Period (for scope including free of cost candle and activated carbon onsite replacement twice a year) 1 2, 1 (or higher) Antiscalant- where silica is up to 100 ppm/where Mica is up to 100 ppm Yes Yes, NA Chloride & Flouride removal facility Yes with Pump Yes with Pump, Yes without pump, No Test Report Availability of type test report(Design Evalution Reports) as per IS:14724 and IS 10500 - * Test certificate No and date: - * Name and Address of - * 2/4 laboratory which conducted Test: * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Mujahid Lateef Sayyed 431122, ZP Complex PW No.2 Division, Main road Beed 134 60