Loading…
Loading…
6,023 results • Best match
Annual Running Contract for Preventive/Routine and Breakdown Maintenance of Electrical System DCRTPP YamunaNagar
The contractor shall carry out various activities of Preventive /routine /breakdown Electrical Maintenance work of Unit-I & II as enlisted below during working hours or at odd hours, including holidays with his skilled manpower as per qualification below: Supervisors (Highly Skilled) for Each Unit as per Annexure (E) – Three year Diploma holder in Electrical with minimum experience of two years. Foreman (Highly Skilled) for Various sites of two general group of Unit I & II each as defined in Annexure(E)–Three year Diploma holders Electrical with minimum 1 year experience or minimum five years’ experience with ITI. He must be able to read engineering drawings and able to attend the fault independently. Technicians(Skilled B) for Various sites of two general group of Unit I & II each as defined in Annexure(E)–ITI in Electrical with minimum 2 year experience. Semiskilled worker (Semiskilled-B) for various sites of two general group of Unit I & II each as defined in Annexure (E) – ITI in Electrical with minimum 1 year experience. Maintenance Shift for each Unit-I & II, DCRTPP as defined in Annexure (E) - three shifts i.e. Morning, Evening and Night with four shift groups with a team of workmen consisting of Foremen and Technician in each shift. The above is the minimum manpower for Various sites as defined in Annexure (E) for each Unit which the contractor has to supply for executing the various maintenance activities for below listed works of Preventive /routine /breakdown Electrical Maintenance work round the clock in Unit-I & II DCRTPP Yamunanagar. However the manpower may be increased depending upon the quantum of work activity or as per the direction of Engineer In Charge. • Attending of Preventive/Routine/break down/repair maintenance work or replacement of all types of illumination fittings and panels in Control Room, Admin. Building, Service Building, Turbine Boiler, BOP Area. Maintenance of different types of welding receptacles, Removal of Circuitry faults of all lighting equipment’s, Junction Boxes, etc. making a cable joint by using jointing kit or dressing, laying & replacement of wiring. Replacement of 125/100/75/50/25 KVA Transformer including testing & Transportation installation, testing and commissioning of power plus fixing of boards, Painting of all lighting boards of Unit I &II of 2X300 MW, DCRTPP. Cleaning of all light fitting covers etc. • Cleaning & greasing of all HT & LT Motors control Panels, HT & LT Panels, Common Auxiliaries of Unit-I & II. Checking of Termination, Cleaning of Terminal Box. Cleaning of insulator, tightening of connection of HT & LT Motors. Removal and reconnection power cable of all HT & LT motors from both ends as and when needs. Shifting & Installation of LT motors up to 5.5.KW. • Shifting of damaged LT motor up to 5.5KW (to and fro) • Attending of Preventive/Routine/breakdown faults of ON/OFF type Motorized valves in Unit-I & II.(Installed at various locations in the main plant & off sites in Unit-I&II) • Cleaning & Tighting of Electrical connections of Exciter, Generator & its associated equipment’s & Panels. Cleaning and replacement of Carbon brushes of all DC motors and Generator rotor shaft etc. • Preventive /routine /breakdown Electrical Maintenance work including Replacement, Servicing and upkeep of EOT cranes, Miscellaneous Hoists and Cranes (electrical part only) installed at various locations of Unit-I & II. • Various miscellaneous work such as shifting of materials, Electrical connections work, fault troubleshooting and removal at various sites etc. For Part-B work extra manpower shall be deployed by the firm.
Custom Bid for Services - AMC of IDPA Backup Device, SAN Storage, Switches and Servers including accessories for two years Similar Category AMC of Integrated Security and Surveillance System Annual Maintenance Contract for Network Security Devices ... Devices Annual Maintenance ... Annual Maintenance Contract ...
Switches and Servers including accessories for two years Similar Category AMC of Integrated Security and Surveillance System Annual Maintenance Contract for Network Security Devices Annual Maintenance Contract for Networking Devices (Version 2)
Customized AMC/CMC for Pre-owned Products - Annual Maintenance Service of Microwave Digestor and TOC Analyzer; As Per RFP; Annual Maintenance Contract (AMC); As Per RFP; No
Customized AMC/CMC for Pre-owned Products - Annual Maintenance Service of Microwave Digestor and TOC Analyzer; As Per RFP; Annual Maintenance Contract (AMC); As Per RFP; No
Customized AMC/CMC for Pre-owned Products - Annual Maintenance contract service of XRF AXIOS MAX-DY6262; As Per RFP; Annual Maintenance Contract (AMC); As Per RFP; No
Customized AMC/CMC for Pre-owned Products - Annual Maintenance contract service of XRF AXIOS MAX-DY6262; As Per RFP; Annual Maintenance Contract (AMC); As Per RFP; No
Custom Bid for Services - AMC of 18 no 3 Ton 1 and half TR2 Hitachi Make Industrial AC for SPR at 400 220 kV Shahjahanpur substation Similar Category Annual Maintenance service-AIR CONDITIONER
Custom Bid for Services - AMC of 18 no 3 Ton 1 and half TR2 Hitachi Make Industrial AC for SPR at 400 220 kV Shahjahanpur substation Similar Category Annual Maintenance service-AIR CONDITIONER
Repair, Maintenance, and Installation of Plant Systems/Equipments (Version 2) - THERMAL POWER PLANT; Non-Comprehensive Annual Maintenance contract (AMC) of M/s Hitachi Hi-Rel makes UPS system installed at 2x250MW, PTPP, Parichha; Service Provider
and Installation of Plant Systems/Equipments (Version 2) - THERMAL POWER PLANT; Non-Comprehensive Annual Maintenance contract (AMC) of M/s Hitachi Hi-Rel makes UPS system installed at 2x250MW