New Construction of Urban Haat at Deesa Dist : Banaskantha
provided accordingly of passenger capacity with Manual Rescue Operation ( Manual Cranking Facility). [9] Audio visual indication in the
Providing Infrastructure Arrangements for the Fourteenth Annual Convocation at IIM Tiruchirappalli
Audio system requirement for convocation: - a) Two-channel Amplifier 1500 Watts or above- 10 Nos. b) 18 Channel or 22-channel digital Audio mixer (Stereo)with required inputs -1 No. c) Stage monitor speakers-2 Nos. d) Goose neck microphone for podium-2 Nos. e) Wireless handheld mic along with required batteries-2 Nos. f) Speakers – 800 W (Min.)- 16 Nos, which should be compatible with the amplifiers mentioned above (item #a). In addition, two speakers to be installed in front of the Library and two at the location where procession starts. g) Two handheld mics along with two speakers to be provided separately for the PA System at the procession origin point. h) Accessories and Cables for interconnecting all the Audio and Video components including labour charges. Video Mixer output along with synchronized audio should be provided for live streaming according to the requirement of the vendor who performs the live webcast of the event. i) All the Audio Visual equipment should be delivered and tested on the previous day of the event (before rehearsal). j) Power extension cables and necessary electrical connectors should be arranged by the vendor according to the site condition. k) Audio files will be provided in pen drive and the same should be played during the event.
Site development, Swimming Pool -50x25m, 8 Lane 400M Synthetic Athletic Track, Sump and Pump room, Bore well, Security cabin, Toilet block, HT electrification, Electrification and Track and Field Equipment
OD239915/2025-2026 Supply, Installation, Testing and Commissioning of diesel engine driven fire pump suitable for automatic operation and consisting of following, complete in all respect as required as per technical specification.(a) Horizontal, split casing, centrifugal type pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal having rated flow 2280 lpm at 75m head, conforming to IS 1520.(b) Suitable HP, suitable RPM water cooled radiator type diesel engine conforming to relevant BS & IS standard complete with auto starting mechanism, 12 volts/24 Volts electric starting equipment,12v 180AH Battery and leads, Diesel Tank Fabricated from MS sheet of 4mm Thick (Minimum Capacity for 8 hour operation) with level indicator, By-pass line, piping from diesel tank to engine, exhaust pipe extended upto 1m outside pump house duly insulated with 50 mm thick glass wool with 1mm thick aluminium sheet cladding, residential silencer, instruments and protection as per specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required.(c) M.S. fabricated Common base plate, coupling, coupling guard etc. as required.(d anti vibration pads/ mounts. (e) Diesel engine control panel
Providing Internal and External Electrification including Lift and Generator set Arrangements to the Construction of 100 Students MBC College Girls Hostel Building at Karambakudi in Pudukkottai District (Second Call)
25.Rectangular copper bus bars (1No for each phase, neutral and earthing terminals) of adequate capacity duly colour coded with head shrinkable PVC sleeves. 26.1No mains voltage monitor 27.Hooter/Audio alarm for indicating set fails to start and for DG O/L. 28.1set Timers 29.Audio and Visual indicator arrangements for: a) Low lubricating oil pressure b) High water temperature c) Over speed 30.1No Earth fault relay 31.Isolator to isolate the neutral Note:- 1. The control panel should be complete with necessary fuses, cables, label, other accessories with neutral isolation arrangements. 2. The engine should trip for the following: a) Low lubricating oil pressure b) High water temperature c) Over speed 3.Supply and fitment of Auto Mains Failure Panel, 1 EB Service wih 63 Amps switch and contactors SUF Control relays, timers etc suitable for auto change over of DG & EB Service. F.FUEL TANK Fuel tank of 100 litres capacity and with inlet and outlet connections, filling cap drain plug, level indicator complete. G.BASE FRAME: Base frame should be fabricated with MS channel frame of rigidly welded construction for mounting the generaor set. The engine and alternator should be coupled by suitably designed diaphragm type flexible coupling with guard and mounted on the base frame wih proper alignment.
SITC OF PASSENGERS LIFT IN DISTRICT COURT COMPLEX KOTA
SITC of Machine Room / Machine room less passenger / Stretcher / Bed elevator confirming to IS:17900 - part I & II and having specifications as per A, B, C, D, E, F, G, H and I mentioned below and all as per pre approved by engineer in charge. For additional technical parameters of products/works, refer Annexure ''A '' attached with P.W.D. Electrical B.S.R. 2022. (a) Doors : Centre/Telescopic opening Doors of 2100 mm height with frame made from Stainless steel grade AISI 304 2B solid (non-cladded) sheet of 1.5 mm thick in Hairline / Moonrock / honeycomb finish for car and all landing doors, The lift doors shall have 2 hour fire rating and 8 lacs cycle per year tested (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory) with key holes and full length infrared curtains and unlocking facility from outside. (b)Car : Lift car enclosure as per available lift well size and height 2300 mm made from Stainless steel grade AISI 304 2B solid (non-cladded) sheet of 1.5 mm, thick with Hairline / Moonrock / honeycomb finish with frame made from MS platform, bracing of adequate size with minimum safety factor of 5, with Toe Guard Apron, with necessary false ceiling with adequate LED lights, blower for ventilation, vinyl flooring or 20 mm recess for granite, Grab bars, mirror, emergency light ,emergency stop device, emergency alarm, mechanical door safety, facility of auto/attendant mode. COP with SS face plate having metallic push buttons with Braille code & luminous indicator around button with FPI, scrolling UP/DN LED indicator & with / without attendant key switch, audio-visual alarm, Door closing/opening button, The lift car interior design shall be done as per the directions of engineer in charge. ( c ) Controller : Microprocessor/ PLC with VVVF and Regenerative Drive having closed loop control system, with IBMS compatible having necessary port. The controller shall have necessary protections such as overcurrent, overvoltage, over speed, overheat for all devices including lift motor and travel direction protection, protection for phase loss at input or output etc. various operation modes such as maintenance, change direction by attendant, full load bypass, VIP call operation, self levelling operation, call cancel facility, auto return to home landing, fireman evacuation operation, earthquake operation, door open/close operation from COP etc. The system can record information for minimum 30 latest faults, with real-time clock management and handheld keypad with LCD screen for view and setting of parameters. The control panel duly wired with proper size & strength, copper wire for power & control circuit, with provision for addition of floor/control card & allied accessories in IP-54 1.5 mm thick SS304 Enclosure
Construction of Block Level Stadium under Badachana Block With Indoor hall_building
Supply and Installation of 43" UHD (3,840 x 2,160) TV with 300 nits brightness,10W+10W Audio Output,Crestron Connected, NTP sync timer, BEACON, Embedded CM (contents manager), Soft AP, WiFi , Screen Share (Miracast), DIAL, Bluetooth Audio Playback,Hotel Mode , Welcome Screen (Splash Image), Insert Image, One Channel Map, IP Channel Manager, External Speaker Out , Remote jack pack, Moving Picture Playback, Auto Off / Sleep Timer,Smart Energy Saving, Motion Eye Care,USB Cloning, WOL, Interface : Set Side - HDMI In 3, USB 1, CI Slot, RF In, Digital Audio Out (Optical), RS-232C, RJ45 , External Speaker Out,Power Consumption(Typ.)-145 W, with 3years Warranty including the cost of labor & material T & P as required as EIC. Make Should be as per approved quality and specifications. It should be approved by the user agency (Sports & YS Department) and the work should be executed as per direction of Engineer in charge.