Loading…
Loading…
127 results • Latest
COMPREHENSIVE MAINTENANCE OF SENSITIVE E/M EQUIPMENTS INSTALLATIONS OF NCN DATA CENTRE AT INS ANGRE UNDER GE(NW) KUNJALI
Annual Maintenance Contract (AMC) for Repairs and routine maintenance of UPS Systems through OEM, total 04 Nos, details as under: (1) UPS Capacity 300 KVA – 01 No (2) UPS Capacity 60 KVA – 01 No (3) UPS Capacity 80 KVA – 02 Nos The scope of work shall include: (1) Preventive and breakdown maintenance of all UPS units. (2) Replacement of defective minor parts such as relays, PCB cards, connectors, etc. (3) Monthly testing of isolation transformer. (4) Weekly testing of voltage and current of all batteries. (5) Preparation of battery status chart, duly signed by the Engineer-in-Charge. (6) Painting of battery stands of all UPS systems. (7) Replacement of batteries and jointing of battery interconnecting cables, as required. (8) Any other accessories not mentioned but necessary for proper functioning. Complete all as specified and directed by the Engineer-in-Charge.
New Construction of Urban Haat at Deesa Dist : Banaskantha
jointing/brazing including accessories, insulated with XPLE Class-0 tubular insulation/with Class-0 closed cell elastometric nitrile rubber
Providing and installing MEP and mandatory Civil works required for Strengthening of the Health infrastructure in the UT of DNH
C-08 UPS SITC of 40kVA Frame with 30kVA modules three phase in and out. with indoor (IP21) with surge protection system with 60 min backup battery @ 30kva 0.8 PF load with min VAH of 60000 Dual string (SMF battery of reputed approved make. Input pf >0.99, with external input isolation transformer, with IGBT rectifier and inverter Double conversion technology, with input voltage range 320-460 @ full load, 50Hz Three Phase, output 400V, 50Hz Three phase, compatibility etc. Output Voltage THDu 6% Full Non-Linear Load According to IEC/EN62040-3including all accessories, frequency regulation 50Hz±0.01%, SMF batteries VRLA type with powder coated CRCA cabinet including all accessories such as output panel required for ups parallels operation, cabling etc as required complete having following specification. The UPS system consist of one numbers of UPS unit and one set of battery bank . The UPS shall be suitable for parellel operation. RS485 Interface compatibility Fully digital controlled based on DSP Power factor corrected from end > 0.9 Pure sine wave output. Full time output voltage & frequency regulation Auto regulation of battery end voltage Intelligent interface with LED/LCD display Static bypass switch / manual by pass switch Auto temperature compensation, Remote Management Interphase, Back up time 30 minutes at full load.
Signalling work in connection with Re-girdering of (1) Br. No. 27 on up Main, Dn Main, Line No.7 and common Line in between station BNXR and DDJ in SDAH-DDJ Section, (2) Br No 7 on UP Main and DN Main line in between station SDAH and BNXR in SDAH-DDJ section, (3) Br. no.1A at NCC yard , (4) Br No. 17 in between Station DBT-BARU in BRP-LKPR section ,(5) Br No. C/9 in between Station PLF-CHT in SPR-CG section, (6) Br. No. X/15 (RUB) on UP & DN line, between station SGBA and PQS in KGK Chord section, (7) Br. no.20 in SDAH-DDJ Section,(8) Br.no. 1CP in DDJ-KOAA Section, (9) Br no. X-23(RUB) in KGK-BLN Section, (10) Br No. 14CCR on UP & DN line, in Ballyghat Station Limit in DDJ-DKAE section & (11) Br. No. 5CCR (RUB) on UP & DN line between station BARN-DAKE in DDJ-DKAE section in Sealdah Division.
65 65 "Charging of lead acid cell (Secondary cell) Numbers 110.00 311.01 34211.10
Annual Maintenance of Electrical Installations in Head Office, RSRDC Ltd., Jaipur
Providing & Fixing of DLP PVC adaptable trunking system for cable management including finishing accessories like corners, tees, adjustable angles, junction etc. as required . The trunking system shall have adaptable system for modular type RJ 45 data socket/ wiring accessories/ power sockets and shall be covered with peal off plastic cover. OEM have to submit NABL accrediated /CPET lab test reports /EN 50085-2-1 complaince certificate.
Providing Internal and External Electrification including Lift and Generator set Arrangements to the Construction of 100 Students MBC College Girls Hostel Building at Karambakudi in Pudukkottai District (Second Call)
Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) (5 points / Coil) Higher End )