Loading…
Loading…
31 results • Latest
food Products
New Construction of 04 No. Permanent Courts at Judicial Court Complex, Dhuri, Distt. Sangrur (Punjab)
Supply and erection of BEE 3-Star rating AC Ceiling Fan 1200mm (48") suitable for 230 V single phase with double ball bearing, copper wound, full aluminium body, 3Nos. of blades, white in colour. The mounting type is down rod mount. The product should possess a minimum air deleivery of 210 CMM (approx.). The rated speed of the the product must be minimum of 300 revolutions per minute and 5Nos. of speeds. The product should have a manufcaturer's guarantee /warranty of minimum 2 years. The product should be complete in all aspects with fan motor, bladeset, down rod, conopy set, shackle kit, twisted wire etc., including erection & testing of ceiling fan having connection with PVC insulated PVC sheathed two single core copper conductor (FR) cable 0.75 sq. mm complete in all respects as per satisfcation of the Engineer in-charge at site.
Construction of Remaining of Hospital 50 Bedded Intergrated Ayush Hospital at Bikaner including Electrical work
Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level. ('Original producers' who manufacture billet directly from iron ores and roll the bilets to produce steel conforming to IS:1786) Thermo-mechanically Treated bars (Conforming of relevent IS code)
Imaging Equipments & Cardio Pulmonary equipments for Kampli new 100Beds Taluka Hospital, Ballari District under 2515-KKRDB (Macro projects) for the year 2024-25
3 DENTAL X-RAY MACHINE, GENERAL Product Name Dental X-Ray Machine PRODUCT INFORMATION Tube voltage (KV) 70KV Tube current (mA) 2 mA Focal spot (mm) 0.4 Should have Total filtration and Inherent Filtration Yes Total filtration in mm Al ≥ 2 mm Al Inherent filtration ≥ 0.5 mm Al Minimum Exposure Time 0.04 to 2 seconds Power supply 220-240 V, 50 Hz single phase Based on DC Current Yes RVG / X Ray Film compatible Yes Machine should have a stable base with sturdy locking wheel mechanism No Wall Mountable No Digital control equipped with an easy ready display indicating with precision Yes Stool for the patient provided No Soft positioning arms for accurate tube positions Yes Light and flexible movements Yes Internally lead coated head tube and cone to avoid scattered radiations Yes Exclusive angular indicating system for head positioning in various radiography techniques Yes High efficiency and greater sharpness of the radiography Yes Additional Parameters Should have high voltage generator with high efficiency in the emission of the X rays Yes Should have free swivel head, which allows easy positioning of head Yes Number of lead aprons provided 2 (0.5 mm lead equivalent) To be supplied with Thyroid shield Yes CERTIFICATION AND REPORTS Compliance to Medical Device Rules (MDR) 2017 as amended till date Yes Availability of valid drug license for the product issued from the competent authority defined under Drugs and Cosmetic Act 1940 and Rules made there under as amended till date Yes AERB Type Approved Model Yes Battery and Adapter must be BIS Approved yes Conformity to Indian Standard IS 7620- Part 1, Part 2, Part 3 Yes Manufacturing unit certification and NABL Certificate YES EPR Electronic and plastic waste certificate yes Availability of Test Report for product as per Medical Device Rules (MDR) 2017 as amended till date Yes Electrical Safety Standards IEC/EN 60601-1 or equivalent BIS Standard Submission of all necessary certifications, licenses and test reports to the buyer at the time of bid submission and/or along with supplies as per buyer requirement Yes WARRANTY Warranty (Option of comprehensive warranty is available through bidding only, which if opted will supersede normal warranty in the catalogue) 3year
Hospital furniture & Accessories for Kampli new 100 Beds Taluka Hospital, Ballari District under 2515-KKRDB (Macro projects) for the year 2024-25
1 Item-1 DR 300 M.A.X-ray machine.DIGITAL Xray 300mA with accessories General The offered Model should be the latest, Static Digital Radiography system suitable for Radiography of all body parts The unit should be a Digital system with Two wired, integrated Flat Panel Detector It should be CE certified / FDA Approved and CDSCO It should have AERB Type Approval All Technical information in the tender document must be supported by original product date sheets Compliance sheets must be strictly under the headings given in the tender document and should be supported by data. Minimum two major components (Tube/ X ray generator/Detector) must be manufactured by manufacturer of Digital Radiography system to ensure optimal functional synchrony and maintenance of the machine. Reference of product brochure and datasheet will be considered as a proof of claim. System should have following specifications as standard: Generator Micro-Processor coontrolled High Frequency X-RAY Generator Invertor frequency: 30kHz or more Output Power of generator :32 KW or more Radiographic KV Range: 40 to 125KV or more with an increment of 1KV per step Exposure time: 1ms to 10sec Digital display of mAs and kV should be available Should have anatomical programming radiography. Should have over loading protection feature. Each 1.00 4653495.00 4653495
Labour ward, Neonatal Opthalmic equipments for Kampli new 100 Bed Taluka Hospital, Ballari District under 2515-KKRDB (Macro projects) for the year 2024-25
1 Item-1 DR 300 M.A.X-ray machine.DIGITAL Xray 300mA with accessories General The offered Model should be the latest, Static Digital Radiography system suitable for Radiography of all body parts The unit should be a Digital system with Two wired, integrated Flat Panel Detector It should be CE certified / FDA Approved and CDSCO It should have AERB Type Approval All Technical information in the tender document must be supported by original product date sheets Compliance sheets must be strictly under the headings given in the tender document and should be supported by data. Minimum two major components (Tube/ X ray generator/Detector) must be manufactured by manufacturer of Digital Radiography system to ensure optimal functional synchrony and maintenance of the machine. Reference of product brochure and datasheet will be considered as a proof of claim. System should have following specifications as standard: Generator Micro-Processor coontrolled High Frequency X-RAY Generator Invertor frequency: 30kHz or more Output Power of generator :32 KW or more Radiographic KV Range: 40 to 125KV or more with an increment of 1KV per step Exposure time: 1ms to 10sec Digital display of mAs and kV should be available Should have anatomical programming radiography. Should have over loading protection feature. Each 1.00 4653495.00 4653495