Loading…
Loading…
109 results • Latest
05/PWD/ADB/PDY/2025-26. Condition Assessment and Rehabilitation of the old Sewerage system at Muthialpet in Puducherry
Consolidated charges for Robotic FIND & FIX On-Spot-Repair technology including Mobilization of Beaver robotic crawler-based ROV equipment and accessories, including supply of rolled-up sleeves and other consumables, for repair of faulty pipelines using Find & Fix Sleeve Technology. (i). Monitoring of On-Spot-Repair process using Pipeline CCTV Inspection equipment. (ii). Measurement of Internal Diameter of Pipe at the fault location using Laser inspection system. (iii). Installation of rolled-up-sleeves including required equipment for installation of the sleeves. (iv). Design and Supply of Robotically installable ROLLED-UP SIeeves made from SS-316 with self locking technology and compatible with On-Spot-Repair robots, of the following sizes.
Construction of Compound wall , Motor Room and Chlorination ward 18 mela at Pattukkottai Municipality
Earth work excavation for foundation in Hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel,stoney earth and earth mixed with small size boulders SS.20B and Sand, silt or other loose soil, wet sand,or silt not under water, light black cotton soil, sandy loam ordinary soil and to full depth as may be directed except in hardrock requiring blasting inclusive of shoring shuttering and baling out water and cleaning and levelling the site etc.,complete 10 cum
Construction of Compound wall , Motor Room and Chlorination Near Housing Board (Vengatachalam Nagar ) in Pattukkottai Municipality
Earth work excavation for foundation in Hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel,stoney earth and earth mixed with small size boulders SS.20B and Sand, silt or other loose soil, wet sand,or silt not under water, light black cotton soil, sandy loam ordinary soil and to full depth as may be directed except in hardrock requiring blasting inclusive of shoring shuttering and baling out water and cleaning and levelling the site etc.,complete 10 cum
Condition Assessment and Rehabilitation of the old Sewerage system at Orleanpet and Rainbow Nagar, Puducherry
Consolidated charges for Robotic FIND & FIX On-Spot-Repair technology including Mobilization of Beaver robotic crawler-based ROV equipment and accessories, including supply of rolled-up sleeves and other consumables, for repair of faulty pipelines using Find & Fix Sleeve Technology. (i). Monitoring of On-Spot-Repair process using Pipeline CCTV Inspection equipment. (ii). Measurement of Internal Diameter of Pipe at the fault location using Laser inspection system. (iii). Installation of rolled-up-sleeves including required equipment for installation of the sleeves. (iv). Design and Supply of Robotically installable ROLLED-UP SIeeves made from SS-316 with self locking technology and compatible with On-Spot-Repair robots, of the following sizes.
Improvements to the Pathalapettai Keelakulam in Pathalapettai Village of Thiruverumbur Taluk of Trichy District
Earth work excavating and depositing on bank with initial lead of 10m & initial lift of 2m in Hard stiff clay, stiff black cotton, hard red earth, shales, murram, gravel, stoney earth and earth mixed with small size boulders SS20B (HARD SOIL)
Operation and Maintenance of the 23 Nos CWSS in Sivagangai and 32 Nos CWSS in Ramnad Districts
Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 0.195 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers Totally 71.175 ML (0.195*365)