Loading…
Loading…
1,534 results • Best match
Electrical works at Ratnagiri lighthouse
Labour charges for the fitting of copper strip size 25x3 mm from Earthing to lightning arrestor,DG Set, On grid Inverter. For Lighting Arrester the earth strip draws under UPVC/CPVC hold with copper clamp and brass screw properly at 2 ft distance on out side of tower in straight line.For DG set, Ongrid Inverter the eath strip underground upto 2ft Including excavation, brazing work and ss nut, bolt.
1 Glass Ionomer cement Restorative type 9, 2 Eugenol liquid, 3 Composite syringe flowable composite, 4 Bonding Agent 5th Generation, 5 Bonding Agent 7th GenUniversal Self etch, 6 Disposable micro tips For bonding agent, 7 Etchant gel, 8 Suction tips ... Regular Set , ... teeth set for ...
4 Bonding Agent 5th Generation
Carpenter hammer 500 gm comma Cross Pen Hammer Drop Forged Steel Seasoned Wood Handle Head Material Alloy Steel, WoodChiesel 1 inch Bevelled Edge Material High Quality Carbon Steel Rubber grip Steel Tipped Handle, Chiesel cold 1 inch dia 6 inch Long ... Die set 1 ... Die set 2 ... Bit set Chrome ... Drill Set 2, ... and General Purpose ... and General Purpose ...
Drill Bit set Chrome Nickel Molybdenum Steel Concrete Drill Set 2
GODREJ STORWEL PLAIN STD, GODREJ MINOR PLAIN STORWEL STD, GODREJ FILING CABINET 4 DRAWER VERTICAL, CHAIR GODREJ PREMIUM PCH 7002D, CHAIR GODREJ REGENCY HIGH BACK 7001D, CHAIR GODREJ 03 SEATER BENCH, TABLE GODREJ EXECUTIVE DESK FINESE STD, BED GODREJ ... OTHERS GENERAL TABLE ... SOFA SET GODREJ ... SOFA SET 3 ...
SOFA SET GODREJ SOFA SET 3 1 1 PISA STD
Procurement of Mobile Instrumentation Van for monitoring the health of power supply instrumentation with full T and P equipment required in the project of VR-DRD and PNVL-KJT
5. Tan Delta/Power Factor & Oil Conductivity using frequency domain spectroscopy technique Megger Model IDAX 300 or similar 6. Mechanical Condition Assessment of Transformer using SFRA Megger Model FRAX101 or similar II. The system should be capable of doing the test below in portable/standalone. 7. Static Contact resistance - Megger Model TRAX280 or similar 8. Magnetic Balance testing - Megger Model TRAX280 or similar 9.CT and PT Analyser - Megger Model TRAX280 or similar 10. Battery Impedance Tester -Megger- Model BITE5 or similar 11. Relay Test Kit - SMRT1 Control Module with switch box - Used for integration for all testing along with central console with display screen for operations and test the transformer in just three modes. 1. HV Switch box 2. Prefery module 3. Control Module 4. Control Console 5. Isolation transformer 6. Software for controlling and reporting Standard lead set with 30 meters length will be provided on drum and extra lead set will be provided for smooth operation. Van Fabrication which includes Air conditioning / Generator / AC Inputs arrangements/ Electrical fittings for laptop and DG set 5KVA
CONTINUOUS RAIL THERMOMETER Continuous Rail Temperature Recorder with facilities to measure and record Rail temperatures up to 18 months on hourly basis. It is having On-Board Programming facility to modify the operations i.e sampling interval, ... time settings . ... printer. Generally and ... CRT-2, generally & ...
Description :CONTINUOUS RAIL THERMOMETER Continuous Rail Temperature Recorder with facilities to m easure and record Rail temperatures up to 18 months on hourly basis. It is having On-Board Programming f acility to modify the operations i.e sampling interval, max./min. temperatures date and time settings. Havin g LCD display hence, nullify the need of computer but with computer compatibility to access the data into e xcel files but without printer. Generally and functionally as per RDSO Specification No.TM/TL/119 (Rev.03 of 2022) or latest. Firm,s offer- PIE?s Continuous Rail Thermometer Model CRT-2, generally & functionally conf irming to RDSO Specification No. TM/TL/119 (Revision 03 of 2022) but improved. MAIN TECHNICAL SPECIFIC ATIONS: ? Display : Alphanumeric 16 x 2 LCD Display / OLED Display. Resolution : 0.1?C. Accuracy : ? 1.0?C . Measuring Range : -5?C to 85?C. Memory : Non ? Volatile memory that can record rail temperature up to 1