Loading…
Loading…
30,272 results • Best match
Repair of old damaged sewerage line and M.H. Chamber at Ward No.63, Central Constituency.
Repair of old damaged sewerasge line and M.H. Chamber at Ward No.63, Central Constituency.
Strengthening of Sewerage (Providing Laying Sewer line For Bhawani Shankar Inter Collage Sector-46) Noida.
Sewerage Operation and Maintenance sewer line in ward no. 08, NIT Faridabad. (For 36 Months)
Sewerage Operation and Maintenance sewer line in ward no. 08, NIT Faridabad. (For 36 Months)
Expansion and Modification of the Existing Sewerage Treatment Plant at NCR Biotech Science Cluster Faridabad
Expansion and Modification of the Existing Sewerage Treatment Plant of 200 KLD capacity at NCR Biotech Science Cluster, Faridabad (200KLD) Including Designing, Dismantling of Internal Electromechanical Setup, Retrofitting, wall tilling & Ventilation system of the STP. Civil Structure, Design, Supply, Installation, Testing, and Commissioning of the Sewage Treatment Plant (STP) on MBBR Technology, The scope under the contract shall cover and include the following works but not limited to be executed by the Contractor on ‘Turnkey Basis’: - 1.Dismantling of electromechanical existing installation and making bypass arrangement of STP water while construction is in progress. 2.Retrofitting of existing civil structure, water proofing, tilling of internal tanks, making foundation of all pumps and motors as per approved design /drawings. 3.Design, supply, installation testing & commissioning of 200KLD (2X100) STP based on MBBR technology, including all the equipment required for the sewage treatment plant Complete in all aspects or as approved in design by engineer in charge/committee members. 4.Contractor will design STP with proper ventilation for the entire STP and suggest that if any modification is required in the civil structure for the ventilation, any work required for modification is in the scope of the contractor. 5.All electrical wiring cabling panels are in the scope of work. THSTI will provide source for the connection whatever cabling or switchgear required for the connection will be in the scope of contractor. 6. The design must fully comply with all applicable norms and guidelines set by local authorities, the Central Pollution Control Board (CPCB), and the Environmental Impact Assessment (EIA). The contractor must ensure that the plant is not only technically sound but also meets all statutory and regulatory environmental standards.
Construction work of patch work of cc road/ sewerage connections ward no 01 to 30
Providing at site, lowering & laying in trenches, aligning & jointing of RCC pipes NP4 class (with s/s ends) IS: 458 - 2003 (amended up to date) marked and pipes from 300 mm and upto 1800 mm manufactured through vertical / vibrated casting process at all depths with Rubber gaskets (EPDM/SBR) for sewer lines as per IS: 5382 (including cost of Rubber gaskets, lubricants) as per drawing, sectional hydro testing of the sewer pipe line (including cost and conveyance of water to site for testing) etc., complete as per specification and / or as directed by Engineer. Note : E/w to be measured and paid separately. Length of pipe shall be measured in between the outer wall of two manholes / Inspection chambers. Pipe in the manhole/inspection chamber’s wall shall deemed to be included in the item of manhole/inspection chamber shall not be payable. 200 mm internal diameter
Const. of Sewerage Line and P/F Paver Block Near Evershine Building, Thakur Village, Kandivali