Loading…
Loading…
1,084 results • Best match
Supply of LT distribution panels including removal of old panels
Supply of LT distribution panels including removal of old panels
LED Luminaire For Road And Street Lights Conforming To IS 10322 (Part 5/Section 3) (V3) (Under BIS Scheme - II), 5A Switch, Non Modular Piano Type Domestic Electrical Sockets ISI Marked To IS 1293, PVC Insulated Copper Cable Single Core and Multi ... Ballasted LED Lamps ... ( LED Bulb) ... II), LED Batten ... Batten Light (LED ... ( LED Tube ... Tube Light )
LED Batten Light (LED Tube Light) (V2)
LED Luminaire For Road And Street Lights Conforming To IS 10322 (Part 5/Section 3) (V3) (Under BIS Scheme - II) (Q2), Bathroom or Toilet Mirror (V3) (Q4), Towel Rail (Q3), Self Ballasted LED Lamps (LED Bulb) (V3) Conforming to IS 16102 (Part 2) ... (Q2), LED Luminaire ... (Q3), LED Batten ... Batten Light (LED ... ( LED Tube ... Tube Light ) ... (Q3), LED Luminaire ... (Ceiling Light ) ...
LED Batten Light (LED Tube Light) (V2) (Q2)
LED Luminaire For Floodlight Conforming To IS 10322 (Part 5/Section 5) (V3) (Under BIS Scheme - II) (Q2), LED Batten Light (LED Tube Light) (V2) (Q2), LED Luminaire For Road And Street Lights Conforming To IS 10322 (Part 5/Section 3) (V3) (Under BIS ... Ballasted LED Lamps ... ( LED Bulb) ...
LED Batten Light (LED Tube Light) (V2) (Q2)
LED Luminaire For Floodlight Conforming To IS 10322 (Part 5/Section 5) (V3) (Under BIS Scheme - II) (Q2), LED Batten Light (LED Tube Light) (V2) (Q2), LED Luminaire For Road And Street Lights Conforming To IS 10322 (Part 5/Section 3) (V3) (Under BIS Scheme - II) (Q2) MSE Relaxation for Years of Experience and Turnover No Startup Relaxation for Years of Experience and Turnover No
LED Batten Light (LED Tube Light) (V2) (Q2)
SUPPLY,INSTALLATION, TESTING, COMMISSIONING AND TRAINING
750 kVAR AUTOMATIC POWER FACTOR CORRECTION PANELS (APFC) (119A) Supply, installation, testing & commissioning of 750 kVAR, 415V, 50Hz, 3 ph, single front, fixed type Automatic Power Factor Correction Panel (APFC) with digital power factor controller, detuned reactors, copper busbar, bottom cable entry, IP 42 protection class, suitable for a short circuit current of 65kA for 1 sec. & other necessary accessories including associated structural steel required for complete installation of the panel & equipment earthing of the panel from both the earthing terminals of the panel to the nearest earthing grid conductor existing at site using Copper conductors of size as per tender technical specifications & drawings. The capacitor banks shall be delta connected type of ratings 25 kVAR, 50 kVAR & 100 kVAR and dielectric shall be Metallized Polypropylene (MPP) type. The panel shall essentially comprise of the following incoming & outgoing feeders: Incoming feeder: 1 No. 1250A, 4P, ACB with microprocessor based releases for O/L, S/C & E/F Outgoing feeders: i) 4 Nos. - 160A, 3P-N MCCB with Thermal-magnetic based protection releases for O/L & S/C along with 185 A (AC-3 Duty) 3P Contactor and 7% Detuned reactor feeding individual 100 kVAR delta connected capacitor bank. ii) 7 Nos. - 100A, 3P-N MCCB with Thermal-magnetic based protection releases for O/L & S/C along with 50 kVAR Capacitor-duty Contactor and 7% Detuned reactor feeding individual 50 kVAR delta connected capacitor bank iii) 7 Nos. - 63A, 3P-N MCCB with Thermal-magnetic based protection releases for O/L & S/C along with 25 kVAR Capacitor-duty Contactor and 7% Detuned reactor feeding individual 25 kVAR delta connected capacitor bank. Ref. Drg. Nos. IP1/119A/05036141/DWG/001/R0, IP1/119A/05036141/DWG/003/R0, IP1/119A/05036141/DWG/002/R0 & IP1/119A/05036141/DWG/004/R0.