Loading…
Loading…
1,767 results • Latest
Purchase of Electrical Material Required for Operation and Maintenance of Street Lighting for the Financial Year 2026-2027
Purchase of Electric Material Required for Operation & Maintenance of Street Lighting for the Financial Year 2026-2027
REPAIR/MAINT OF EOT CRANE/PASSENGER LIFT UNDER GE DRONACHAL
Comprehensive, preventive and periodical maintenance of Lifts (04 Nos) by OEM Elevator India pvt Limited) of 8 passengers (544 Kg) /500 Kg goods lift - 04 Nos (details mentioned as under) each with travelling speed of 1.0 metre/sec to 1.5 metre/sec installed at 21 corps main Building Under GE Dronachal having SS car enclosure, microprocessor controlled with VVF drive, simplex dual controlled operation, with/ without attendant,automatic sliding SS doors, automatic rescue device including maintenance free battery, 3D infra-red sensor to the full height of door, built in announcing system , in reliable, safe, technical sound and efficient manner using latest techniques & expertise consultancy (by OEM manufacturer or their authorised agent); by regularly examining lubricating and adjusting the mechanical and electrical driving equipments, governor sleeve, shaft assembly, bearing/contact/governor jaws, car & hall mechanical buttons, car & hall position indicators, car direction indicators and all other car and landing signal/fixtures, deflectors, car and counter weight guide rails and buffers, etc including replacement of all defective /spares parts other than mentioned e.g. wires, lugs, nut bolts, screws, hand rails, light luminaries, ventilating fan, holder, lubricant, gear oil, air cord, landing wheel air cord wheel, rubber bush, rail guide shoe, all types of control panel & all type of their cards and software i.e. Air communication card, TTU card, computer card, hardware card, PCB, etc including welding, cutting, drilling etc and any other items required for smooth functioning of lifts for following lifts complete all as specified and directed by Engr-in-Charge. (a) 08 Passenger/544 KG . 1.5m/s, G+3 Floors - 01 No. (01 No. lift with machine room , MES No 676/7009/LF-13, Kone Elevators Sr No. 103890818) (b) 08 Passenger/544 KG . 1.5m/s, G+4 Floors - 02 No.(Machine room less (MRL), MES No 676/7009/LF-13, Kone Elevators Sr No. 104076300 & 1 No lift machine room less (MRL) MES No. 676/7010/LF-13, Kone Elevators Sr No. 104076306) (c) goods Lift 500 Kg 1.0 m/s, G+4 Floors - 01 No ( With machine room. MES No 676/7012/LF-13, Kone Elevators Sr No. 1341240012)
Construction of Community Hall Building at Kalaramam Park in Ward Secretariat-43 under Division-24 in Anantapur Municipal Corporation.
Supply, fabrication, erection and fixing of Mild steel- C Channels, tubular sections, Plates for making of container shops including cost and conveyance of all the materials like Providing wall panelling with corrugated Gi sheets ,flooring using vinyl flooring on cement bonded boards of 18 mm thick ,ceiling and internal partitions using MDF boards-12mm, with wiring concealed and shall be PVC insulated copper wires suitable for Electrical system should be done as per capacity of 250 volts, 50 hz. 2.5 Sqmm cable for main cable and 1.0 Sqmm cable would be used for Lights, Fans and painting with synthetic enamel paint labour, operationl & incidental charges etc., complete for finished iem of work as directed by the Engineer-in-Charge Dimensions of the shop 10ft (L) x 8ft(D) x 9ft (H) (BMM-V-14, BMM-V.16 ) MS / GI Steel (4 Shops x 8 Containers As Per Above Specifications) 4 X 596.91 = 2387.64 X 8 = Total 19101.12 Kgs
Construction of Ayurvedic Health Sub Centre building at Reog Tehsil Kumarsain District Shimla. SH Providing E.I. therein.
Providing and installation of stationary storage type Electric water heater (Geyser) of various sizes with 8 bar pressure rating Five star BEE rating and safety valve installation by means of expansion-bolts with nuts and washers, including embedding of expansion-bolts in the wall, making good the damages, electrical connections, testing etc. complete as required:- :
Annual repair and maintenance of electrical installation in A B Block and principal office at IGMC Shimla. SH Replacement of LED tubes LED panel exhaust fan and geysers etc. at block A B and C
Providing and installation of stationary storage type Electric water heater (Geyser) of various sizes by means of Expansion-bolts with nuts and washers, including embedding of expansion-bolts in the wall, providing and fixing of Non-return valve, Dead weight safety valve, 2 No C.P. connection rods 18" long, making good the damages, electrical connections, safety valve connections, testing and commissioning etc. as required:-
Conservation, Restoration and Rejuvenation works of the Chola Mikirbheta Beel of Nagaon District under Assam SWIFT Project
SOLAR LAMP: Supply, Installation, Testing and commissioning of a Complete solar street-lighting system, including a 160Wp crystalline silicon solar photovoltaic module supplied with a compatible module mounting structure, clamps, fasteners, and UV-resistant cable tails, with test certification conforming to IEC 61215 (Edition II)/IS 14286 and IEC 61730 from a NABL or IECQ accredited laboratory. The system shall incroporate a Lithium Iron Phosphate (LiFePO4) battery of 12.8V nominal voltage and 42 Ah capacity, equipped with an integrated Battery Management System (BMS) providing protections against over/under-voltage, over-current, short-circuit, over-temperature, and ensuring cell balancing, duly certified to IEC 62133-2011 or the latest BIS standard by a BIS-recognized lab or MNRE-accredited test centre. The MPPT charge controller, integrated with the luminaire and battery, shall operate at 12.8 V noinal, have a maximum current rating of 6A/12 A/14 A as required and provide automatic dusk-to-dawn operation, LiFEPO4 charging profiles, and full electronic protection. The LED street-light luminaire shall be rated at 30W(+5%), with high-effciency optics, a driver compatible with the MPPT output, and ingress protection of IP66 or higher, complying with relevent BIS standards, The system shall be mounted on a 6m long 2.2mm thick tubular hot-dip galvanized GI pole conforming to IS 1161 and IS 4736 complete with a single-arm bracket, MMS, and light arm to hold the luminaire and PV module, along with all necessary clamps and fasteners. The work shall include complte erection on a prepared foundation, all wiring and interconnection, functional testing (dusk-to-dawn operation) in the presence of the Engineer-in-Charge, and submission of as-built documentation. The contractor shall also provide a Comprehensive Maintenance Contract (CMC) for a period of five years from the date of commissioning covering preventive and breakdown maintenance, replacement of defective parts, and maintenance of illuinataion levels as specified.