Loading…
Loading…
10,430 results • Best match
Emergency work for electrical main cable line change at Egra SDH, Egra
Supply & delivery of 230 V, 50 Hz, single phase, 52 watts, 48" (1200 mm) Sweep, speed 320 rpm (minimum), A.C. Ceiling Fan and class of insulation: B, 3 nos. metal (Aluminium alloy) blades, 30 cm long down rod (14 SWG & higher thickness), 2 nos. canopies, safety rope, copper winding, steel/Al body. Power Factor not less than 0.9 and minimum air delivery 210 cu.m/min (minimum), without Regulator including capacitor with safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for compliant to IS 374:2019 and external connections with 1.5 sq.mm FR, PVC insulated copper conductor single core cable and earthing etc. as required. (Make- Usha Striker (PWD)/ Crompton )
Electrical Renovation work of Type VI Quarter at CFMTI and TI Budni MP Subwork/Packages: Electrical Renovation work of Type-VI Quarters at CFMT and TI Budni MP
Custom Bid for Services - FABRICATION NERECTION & INSTALLATION OF UV STABILIZED HIGH DENSITY POLY ETHYLENE MADE ANTI KITE FLYING/ANTI BIRD NET ON 33/11 KV -525100 Similar Category Operation and Maintenance Of Electrical Systems/Electrical ... Systems/Electrical Installations
Custom Bid for Services - FABRICATION NERECTION & INSTALLATION OF UV STABILIZED HIGH DENSITY POLY ETHYLENE MADE ANTI KITE FLYING/ANTI BIRD NET ON 33/11 KV -525100 Similar Category Operation and Maintenance Of Electrical Systems/Electrical Installations
Custom Bid for Services - FABRICATION NERECTION & INSTALLATION OF UV STABILIZED HIGH DENSITY POLY ETHYLENE MADE ANTI KITE FLYING/ANTI BIRD NET ON 33/11 KV -623040 Similar Category Operation and Maintenance Of Electrical Systems/Electrical ... Systems/Electrical Installations
Custom Bid for Services - FABRICATION NERECTION & INSTALLATION OF UV STABILIZED HIGH DENSITY POLY ETHYLENE MADE ANTI KITE FLYING/ANTI BIRD NET ON 33/11 KV -623040 Similar Category Operation and Maintenance Of Electrical Systems/Electrical Installations
Construction of Vegetable and fruit vending zone Sitapur Eye Hospital electrical work
Supply installation testing and commissioning of LT panel Board for the extension of existing panel as per the following specification with proper copper earthing as recommended. The panel should be Designed as per the latest standard IEC 61439. The panel should have Bus bar clearance of 25 mm for Ph to Ph and 19 mm for Ph to neutral, Zero Stray voltage doors and panels, polyester glass support for insulation. The cable alleys should be 300 mm wide and it should be fitted with hinged door that open up to and angle of 95 Deg. The provision of cable entry should be from Bottom. The IP protection of panel should be IP-42 for external and IP2X for internal with 3B as Form of separation. The panel should be equipped with suitable size of CT and display meter for VAF measurement. The panel should be suitable for seismic zone V. Make of panel: L&T (Ti), ABB (ArtuK), Schneider (OkEN) 57 Nos. 25 Amps. DP MCB 8 Nos. 16 Amps. DP MCB 2 Nos. Space & Spare 60 Amps. TP&N aluminium bus bars 1 Set of ON / OFF indicating lamps with Single Pole MCB. 1 Set of phase indicating lamps with Single Pole MCB.
ARMO electrical work at FSD Bomdila SH Renovation of internal electrical wiring of godown including replacement of existing PVC conduits with steel conduits
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way , Double door