Loading…
Loading…
11,364 results • Best match
PROVN OF LIGHTING FOR ADM AND OFFICE COMPLEX OF HQ MG AND G AREA UNDER GE (WEST) COLABA, MUMBAI
Supply and laying of cable insulated screened PVC bedded, unarmoured, sheathed, electric power cables 1100 volts grade with stranded copper conductor of size 1.5 Sqmm x 3 core for connecting up to post top lantern, garden light and looping box, complete all as specified and directed.
Provision of air conditioning at various EI installations of Pune division for reliable and safe operation of Electronic interlocking systems over Pune division
Preparation and submission of drawings in A3 Set size with all relevant details and installations, cable routings, lighting arrangements, SLD, earth pit layout, etc. The contractor shall initially... drawings containing the above details for review and approval. After completion of the work, final completion drawings incorporating all measurements and executed details shall be ...
Replacement of Signal posts, Batteries, Mechanical gadgets, Replacement of over aged defective cables and other reliability improvements works at LC gates in TVC Division.
10.00 No.SG/CN/02/13 and earthing of metallic sheath and armour of all cables in all apparatus cases, relay room, equipment room, SM's room for block and control, and earthing of all equipments in apparatus cases, power room, relay rack, cable termination rack, ...
Water Supply Scheme for Augmentation of UWSS uchchain, Distt. Bharatpur including 5 year OnM after 1 year Defect Liability period under Amrut 2.0
Construction of Pump house of RCC framed structure as per approved standard GA, structure, electrical drawing, scope of work and technical specification complete work in all respect including electrical works for indoor and outdoor lighting and fans, rain water drainage, sanitary, plumbing, monorail/ EOT crane etc for Earth quake zone II and SBC equal to or more than 7 T/sqm.
PROPOSED CONSTRUCTION OF NAGARPALIKA OFFICE BUILDING IN CITY SURVEY NO. 1177 IN WARD NO. ________AT VANTHALI. under S.J.M.M.S.V.Y.
(a) For Electrical Installation up to 440V in
SPL REP TO BLDG NO. OWT-74, 75, 76, 77, 78, 79 AND 80, TOILET AND BATHROOM BLOCK, SPL REPAIR TO BLDG NO OWT-237 COVERED FD TECH SHELTER, CONSTRUCTION OF SENTRY POST NEAR BLDG NO T-95 OF 369 AND SPECIAL REPAIR TO BLDG NO OWT-65 AND OWT-75 AT BORARUPAK
Supply and laying cable XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 16 Sqmm 4 core,... under floor of through walls etc jointing and testing including taking out/down existing cable complete all as specified and directed. (Note: Excavation and earth work will be measured and paid seperately)