9,993 results • Best match
Improvement of Kitchen of 120 Men Jawan Barrack at Ftr HQ (Spl Ops) BSF Odisha at Bangalore.( SH Electrical Work)
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C
NHM - CONSTRUCTION OF NEW BUILDING FOR JANAKEEYA AROGYA KENDRA ITTIVA MAIN CENTRE AT KOLLAM DISTRICT- Civil and Electrical Work
1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
Work of construction of separate 11KV Electrical line for Sainik School Site-Village Shankargarh Post Bhagwantpura Block Baragaon District Jhansi.
Supply of Earthing complete
Providing and laying armoured cable main panel and ground floor to 5th floor at civil hospital Palampur (OPD BLOCK)in Tehsil Palampur , Distt. Kangra(H.P.).
Providing & Laying of one number aluminium conductor, PVC insulated and PVC sheathed armoured/ XLPE power cable, 1.1 KV grade of following sizes on wall surface as required.Armoured cable 25 sq. mm (Four Core)Make : KEI/Havells/ Grandly
GENERAL-Replacement of AC in the PPU office at public office complex-PPU AC replacement-Electrical AC Work
OD318322/2025-2026:Supply , Installation, Testing and Commissioning of 2TR, Air Cooled Hi Wall Invertor split type Air conditioners of ISEER 5 or above complete with Indoor unit(IDU), Out door unit (ODU), Copper evoporator coil and condensing coil , surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celcius. Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature) with comprehensive maintenance contract up to the end of DLP period including periodical services, gas topping etc. complete (Including stand)