Loading…
Loading…
11,132 results • Best match
Annual Plan-Koduvally Block panchayathsheeting front portion Vanitha Vyavasaya Kendram Thamarassary under block panchayath Koduvally -Modification of Electrical Installation -General Electrical Work
90.14.1.2:Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623. Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame)
Electrical works
Carriage of materials:- 141 No. Earthing of pole by MS Earth rod 20X2500mm. 810 No. 11KV Pin insulator (Polymeric), 432 No. 11KV Disc insulator with fitting T&C TYPE 45KN, 228 No. 11KV Disc fitting, 217 No. 11KV V-Type cross arm, 03No. 11KV TPMO, 25 No. 11KV Cable Jointing kit I/D 300sqmm. 09 No. 11KV Cable Jointing kit O/D 300sqmm. 5 No. 11KV Fuse set, 03Kg. 6Swg earthing wire from PVVNL Store Sahibabad/ Ghaziabad/Noida to site of work including loading & unloading at both side. Distance 1 km to 50 km. fix at required site to complete work as per respo norms.
Custom Bid for Services - FULL DEPOSIT SCHEME SEMI TURNKEY WORK OF BUNDELKHAND HIGHWAYS PVT LTD VILL LUHARI POST RANIPUR BLOCK BANGRA TO ISSUE 49 KVA LMV 2 NEW CONNECTION UNDER EDD MAURANIPUR Similar Category Operation and Maintenance Of Electrical ... Systems/ Electrical Installations ... Systems/Electrical Installations Repair, ... and Installation of ... and Installation of ...
Custom Bid for Services - FULL DEPOSIT SCHEME SEMI TURNKEY WORK OF BUNDELKHAND HIGHWAYS PVT LTD VILL LUHARI POST RANIPUR BLOCK BANGRA TO ISSUE 49 KVA LMV 2 NEW CONNECTION UNDER EDD MAURANIPUR Similar Category Operation and Maintenance Of Electrical Systems/Electrical Installations Repair
RETENDER GENERAL Central prison and correctional home Tvpm Rewiring and additional electrical installations in Block 7 8 9A 9B 10A 11 12A and Hospital Rewiring General Electrical Work
1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
Providing and Fixing Interior Works for Office Block Including Modular Partitions, work stations ceiling and electrical fixtures etc at Regional office Amaravati
LED Panel light 2x2 ft. (System lumen efficacy =105 120 lm/Watt) Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD 10% , P. F.=0.95, IP20, CRI >80, UGR (Unified Glare Rating) 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) 3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy =105 120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) 36 watt
Custom Bid for Services - 33 KV line strengthening work and LT line Strengthening work & other LT line associated work on Semi-Turnkey basis in Business Plan 2026-27 under the area of EDD, Kiraoli & Kheragarh Agra Similar Category Repair and ... Of Electrical Systems/Electrical ... Systems/ Electrical Installations ... Systems/Electrical Installations Repair, ... and Installation of ... and Installation of ...
Kiraoli & Kheragarh Agra Similar Category Repair and Overhauling Service Operation and Maintenance Of Electrical Systems/Electrical Installations Repair