Annual routine and preventive maintenance of the Electrical installation at Sub Divisional Court, Correctional Home , SDO Office Campus and other Govt. buildings, Contai, Purba Medinipur.
A.1.3 Safety & Equipment Provide caution boards such as “Men on Line”, “Don’t Switch On”, etc. Ensure all staff use proper uniforms Follow all provisions of the Central Electricity Authority Safety Regulations (2023) and ensure any non-compliant installations are corrected immediately. Adhere strictly to BIS Code 5216:1982 for electrical safety practices. Keep electrical areas (substations, switch rooms, DG rooms, cable shafts) clean and free from storage or waste. Store inflammable materials only in designated rooms built as per legal requirements. Provide proper safety gear (gloves, earthing rods, belts, resuscitation equipment) to staff. Maintain accessible first-aid boxes with standard supplies. Before electrical work: disconnect power, display warning signs, secure fuses, and obtain a “Permit to Work.” Ensure high-tension lines are fully discharged and earthed. After work: remove tools, ensure no personnel remain inside, restore normal connections, and officially close the permit before re-energizing. In case of electrical accidents: immediately switch off power, safely remove the victim using non-conductive materials, move them to safety, and provide continuous artificial respiration.
Supply of the Materials for the work of "AME for repairs / Replacement / Maintenance of wiring and electrical accessories etc., to the institution of various temples & K.M' etc., in TPT, Chittoor, Kadapa & Kurnool, Nandyala Dist. under the jurisdiction of AE(Elec.) SSKM Section Tirupati for the year 2026-27" (Part-B)
Supply of 205 X 255 X112 Sizes thermo plastic cable junction boxes with IP66/67 weather proof, for outdoor installation with konckouts for cable entry including terminals etc., complete (sizes in mm) Make : Hensel/Sadhrish
Engagement of Project Management Consultant (PMC) for Providing MEP like high and low side Electrical, HVAC, Fire Protection System, Lifts, Fire Alarm and Public Address System and plumbing works ,Facade with Lighting and Interiors in Integrated Andhra Pradesh State Secretariat and HoD Offices (GAD Tower,Tower 1 and 2,Tower 3 and 4) in Amaravati Government Complex, Andhra Pradesh)
CFRMC Work
Wiring for plug on board with Switch socket surface/concealed type, copper wiring and earthing and with modular accessories as per specification No: WG-PW/CW
Refurbishing of Smart Classrooms of Room No. 222 at Medicine Division, Division of Extension Education, LPM Section, Animal Genetics Division, P & T Division, Committee room of Immunology Section, Anatomy Section, B&M Division, Room No. 121 at ... (SH: Electrical Work) ... Electrical Work )
Annual Operation Repair and Maintenance of Electrical installations at 27 SCG, NSG Chennai during 2026-27 (SH R and M Periodical Servicing and AMC of CUMMINS make DG sets)