Loading…
Loading…
10,733 results • Best match
CFRMC work
Providing and fixing lightening conductor system comprising of erecting Air-Termination consisting of tubular copper rod of 25mm dia. 1.2 mm thick with multiple points head 1.2 mt. long ( Heavy Duty) welded or clamped to G.I. pipe pole B grade 50 mm diaof requiired length with M.S. round bnase plate 25 Cm diam and 10mm thick at bottom embeded in cement concrete 1:3:6 dfoundation of size 45 cm diam x 45 cm Height and providing earthing with copper earth plate of size 60 x 60 x 0.3 cms with cadmium plated nut bolts to fix earthing strip burried in specially prepared earth pits 1.5 metre below ground level with 40 kg charcoal and salt with altemate layers of charcoal and salt and G.I.pipe 40mm dia 2 meter length burried in earthe upto earthling plate remining portion above ground level for watering and refilling comcpete Note- Copper strip fropm lightening conductor is not considered in this item.
Repair, Maintenance, and Installation of Plant Systems/Equipments (Version 2) - bhilai nagar nigam area; Electrical System or Installation, motor power capacitor 2 kvar, voltage 440v 415 v ac, 3 phase 50 hz; Service Provider
and Installation of Plant Systems/Equipments (Version 2) - bhilai nagar nigam area; Electrical System or Installation
Electrification
Electrification of physiotherapy centre
Repair, Maintenance, and Installation of Plant Systems/Equipments (Version 2) - GRAM PANCHAYAT BAANK; Electrical System or Installation, RTPS SYSTEM WITH ALL RELATED ACCESORIES(PRINTER, PRINTING PAPER, WEB CAM, CPU, DESKTOP, MONITOR, SPEAKER, ETC), AND WIRI..
and Installation of Plant Systems/Equipments (Version 2) - GRAM PANCHAYAT BAANK; Electrical System or Installation
electrification
1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
Establishing 2x20MVA, 110/11kV GIS Sub-station at BIMS(Civil Hospital) in Belagavi Taluk & District,2.Construction of 1No. of 110kV Terminal Bay at 110/33/11kV Neharu Nagar Sub-station for terminating proposed 110kV class 630sqmm XLPE UG cable from ... District,3. Laying of ... UG cable for ... Civil Works ) ...
CE11 Underground Fibre Optic cable & Accessories : Laying of 48 Fibrer Window Mono Mode (DWSM) UG Optical Fibre Cable as per drawings and specifications in cable trunch parallel to 110KV cable inside PLB pipes by pulling drawings etc including transportation handling cable drums,paving out cables using standard cable installation equipments and as per direction of the engineer incharge. mtrs 2300.00