Loading…
Loading…
60,039 results • Best match
85629 Annual Plan-DPT 2024-25 - Maintanence works and renovation works of office and class rooms at GVHSE Kadappuram - Chavakkad BP-S0237/25 - SO-1098/2026-Chavakkad BPGeneral Electrical Work
90.2.2.1:Supply and wiring points according to IS 732-1989 through the existing conduit with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (Group B/ RoHS compliant modular accessories).Single Control light point with 6A, plate ceiling rose - Short point
Operation and Maintenance Of Electrical Systems/Electrical Installations - Supply and installation, testing, commissioning of 400A, 250A switch with related cable Servo Hydraulic Test Stand at AOD, Ground floor, AIESL, Engg, OAP, Mumbai-29
Operation and Maintenance Of Electrical Systems/Electrical Installations | Billing:monthly | Amount:439372.98
TEMPORARY ELECTRICAL INSTALLATION WORK INCLUDING DG SET and SOUND SYSTEM INCONNECTION WITH WBLA ELECTION 2026 AT MALDA POLYTECHNIC MALDA.
TEMPORARY ELECTRICAL INSTALLATION WORK INCLUDING DG SET & SOUND SYSTEM INCONNECTION WITH WBLA ELECTION 2026 AT MALDA POLYTECHNIC MALDA.
TEMPORARY ELECTRICAL INSTALLATION WORK INCLUDING DG SET and SOUND SYSTEM INCONNECTION WITH WBLA ELECTION 2026 AT MALDA COLLEGE MALDA.
TEMPORARY ELECTRICAL INSTALLATION WORK INCLUDING DG SET & SOUND SYSTEM INCONNECTION WITH WBLA ELECTION 2026 AT MALDA COLLEGE MALDA.
Supply, Installation, Testing and Commissioning of 20 Passenger (1360 Kg) lift alongwith civil work and electrical work at Mata Gujri Hospital, Tilak Nagar.
Supply, Installation, Testing and Commissioning of 20 Passenger (1360 Kg) lift alongwith civil work and electrical work at Mata Gujri Hospital, Tilak Nagar.
Renovation work of electrical installation in admin block, workshop and washing plant at DTC Noida Depot.
LED Batten light 18- 22 watt (System lumen efficacy ≥120 135 lm/Watt)Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range - 15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD 10% , P. F.≥0.95, IP20, CRI >80 , Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends,CCT 3000°K / 4000°K / 5700°K /6000°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) 3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). CRCA Sheet Body (Thickness ≥ 0.50 mm)