Loading…
Loading…
58,460 results • Best match
Annual Plan-Appalam Vayojanakendhram Electrification and related works (Electrical works ) at Kalpetta Block panchayat.-242/25- 26-General Electrical Work
DEPOSIT-Government Ayurveda college, Thiruvananthapuram - Renovation of Academic staff room and allied works in Pharmacy building-Electrical Renovation works-General Electrical Work
Electrification
RMO of Electrical and Mechanical installations at Saheed Rajguru College at Vasundhara Enclave, Delhi E.I work of changing room in basement and other associated works)
17 LED Down lighter (SMD Type) (System lumen efficacy ≥ 105 120 lm/Watt) Supplying, Installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -50C to 400C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) 19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K /4000°K / 5700°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) 3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and 120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminium Body including trim 12 -15 watt 30 Nos 715 374800 Excess(+) Full Conversion INR
Operation and Maintenance Of Electrical Systems/Electrical Installations - NIT Schedule of Item for Installation of a 63 KVA transformer near the house of Mr Sanjay Gupta the Gram Uphaar along with the required electrification work Assembly Constitue..
Operation and Maintenance Of Electrical Systems/Electrical Installations - NIT Schedule of Item for Installation of a 63 KVA transformer near the house of Mr Sanjay Gupta the Gram Uphaar along with the required electrification work Assembly Constitue..
Renovation work comprising of Civil Works, Electrical Works, HVAC, fire fighting work, furniture work, etc.
SH-l EI- Point Wiring, DB, Earthing, Lighting, Cable, Cable Tray, LT Panel 4,60,855.00 8,18,669.16
Operation and Maintenance Of Electrical Systems/Electrical Installations - NIT Schedule of Item for Electrification work in Gram Chhaitaini Loni 521 Assembly Constituency Sirmaur
Operation and Maintenance Of Electrical Systems/Electrical Installations - NIT Schedule of Item for Electrification work in Gram Chhaitaini Loni 521 Assembly Constituency Sirmaur