BRICK WORK CC WORK PLUMBING WORK ELECTRICAL WORK ETC.
[24.13.13]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 13. 10 Sq mm 2 core (UnArm.) [Through Rate]
Brick Work , CC Work, Electrical Work, Plumbing Work etc.
[24.13.13]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 13. 10 Sq mm 2 core (UnArm.) [Through Rate]
Special Repair works to the Electrical Installation with Inside and Outside Lighting arrangements to the Existing Godown Campus at Thachampadi Village in Chetpet Taluk in Thiruvannamalai District
Supply, Fabrication, Commissioning and Testing of 50 Watts -LED-Solar-Off Grid - Street Light with Gi- Post .The cost includes material cost, transportation cost, masonry work cost, any escalation in GST-cost as arises, Fabrication charges for Street light Post, Electrical wiring with material cost and labour cost as required at site. The Solar PV panels and LED light fittings to be ISI make and to be satisfy to TEDA norms as directed by the departmental officers. Solar PV Module 12 Volt- 90 Watts - Mono- crystalline. The modules are designed to withstand highly corrosive atmosphere and heavy wind loads and of certified standards. Temperature of Operation should be of 10 to 50 degree Celsius with Thermal Management System for ambient temperature in lower & higher rated value. The controller to be MPPT.(ISI Make) Battery-Lithium Ferro Phosphate make and designed for tropical conditions and have a long life. Minimum Voltage - 12.8V, 42 AH capacity ( ISI make) LED Light- White Light Emitting Diode (W-LED) (ISI Make) 12 Watt, W-LED luminary, dispersed beam, soothing to eyes with the use of proper optics and diffuser.LED Chip is of compliance to IES: LM-80 (Approved Method for Measuring Lumen Maintenance of LED Light Sources and LED lumen depreciation time to L70). Test report to be submitted before installation and to be get approval from Departmental Officers. The Color Temperature to be between 5500 K to 6500 K. The Die cast Aluminium IP66 enclosure provides excellent Protection against water entry, dust and humidity. Street light Post:- GI- Class-B (ISI norms) Pole height 6.5 m above the ground level. The G.I post must with 300mm x 300mm x 6mm MS base plate duly welded at the bottom and with concreting and construction on masonry pedestal.
INSTALLATION OF LIGHTING ARRANGEMENT BY LED LIGHT FITTINGS AND OTHER ELECTRICAL WORKS AT STRAND RD AND OTHER SURROUNDING AREAS IN WARD NO.-42 FOR PART NO.-224
1.00 PIONEER ELECTRICALS (GSTN-NA) BID ID -10046824 249591.20 1.76 253984.01 Two Lakh Fifty Three Thousand Nine Hundred and Eighty Four
Special Repair works to the Electrical Installation with Inside and Outside Lighting arrangements to the Existing Godown Campus at Perungattur Village in Vempakkam Taluk in Thiruvannamalai District
Supply, Fabrication, Commissioning and Testing of 50 Watts -LED-Solar-Off Grid - Street Light with Gi- Post .The cost includes material cost, transportation cost, masonry work cost, any escalation in GST-cost as arises, Fabrication charges for Street light Post, Electrical wiring with material cost and labour cost as required at site. The Solar PV panels and LED light fittings to be ISI make and to be satisfy to TEDA norms as directed by the departmental officers. Solar PV Module 12 Volt- 90 Watts - Mono- crystalline. The modules are designed to withstand highly corrosive atmosphere and heavy wind loads and of certified standards. Temperature of Operation should be of 10 to 50 degree Celsius with Thermal Management System for ambient temperature in lower & higher rated value. The controller to be MPPT.(ISI Make) Battery-Lithium Ferro Phosphate make and designed for tropical conditions and have a long life. Minimum Voltage - 12.8V, 42 AH capacity ( ISI make) LED Light- White Light Emitting Diode (W-LED) (ISI Make) 12 Watt, W-LED luminary, dispersed beam, soothing to eyes with the use of proper optics and diffuser.LED Chip is of compliance to IES: LM-80 (Approved Method for Measuring Lumen Maintenance of LED Light Sources and LED lumen depreciation time to L70). Test report to be submitted before installation and to be get approval from Departmental Officers. The Color Temperature to be between 5500 K to 6500 K. The Die cast Aluminium IP66 enclosure provides excellent Protection against water entry, dust and humidity. Street light Post:- GI- Class-B (ISI norms) Pole height 6.5 m above the ground level. The G.I post must with 300mm x 300mm x 6mm MS base plate duly welded at the bottom and with concreting and construction on masonry pedestal.
Execution of different works for installation of new MS panel protection boxes with electrical works as per scope of work to make water supply from tube wells and sump well such as taking out of old damaged MS panel protection boxes, wooden boards an