Loading…
Loading…
62,204 results • Best match
Electrical wiring, rewiring and misc. EandM works at various office complexes
12.0) Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD 10%, P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker shouldbe below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) 3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). 18-22 Watt
Providing Electrical Installation to the work of Additional Scientific Storage Godown of 3000M.T capacity in TNCSC Godown campus at Thelur Village in Ariyalur Taluk and District
Earthing as per the ISI specification with an earth electrode of 2.10 meter Class 'B' GI pipe of dia not less than40mm with copper earth plate of size 125mmx50mmx 6mm with necessary funneling arrangements with necessary masonry etc., complete complying with standard specification and as directed by the departmental officer
200150172 HT CABLE LAYING FROM STG-02 TO STG-01 NTPC Barauni
HT CABLE LAYING
GENERAL-Anticipatory Running Electrical Maintenance Contract to EI in Civil Station Buiding, Thiruvananthapuram for the period 2025-26-Anticipated Electrical Maintenance.- General Electrical Work
Work Name:GENERAL-Anticipatory Running Electrical Maintenance Contract to EI in Civil Station Buiding, Thiruvananthapuram for the period 2025-26-Anticipated Electrical Maintenance.-General Electrical Work
GENERAL-Electrification works in connection with the Installation of Air conditioners in Steno Pool -Providing electrical connection to the Air conditioners in Steno Pool -PA to Judges main section, and Annex section, at 2nd floor of new High Court b
RMO of Specialized Electrical Mechanical works at AU Tibbia College and Hospitals, Karol Bagh, ND.SH. Upgradation of Electrical Sub Station Installed at AU Tibbia College and Hospital, Karol Bagh
eTendering System Government of NCT of Delhi Created By: Abhishek Mani Tripathi Created Date/Time: 08-Jan-2026 12:56 PM Tender Title: RMO of Specialized Electrical Mechanical works at AU Tibbia College and Hospitals, Karol Bagh, ND.SH. Upgradation of Electrical Sub Station Installed at AU Tibbia College and Hospital, Karol Bagh Tender ID: 2025_PWD_283788_1