Loading…
Loading…
59,317 results • Best match
Operation and Maintenance Of Electrical Systems/Electrical Installations - Work of Maintenance and replacement of lighting fixtures street light points etc at TPS Gandhinagar
Operation and Maintenance Of Electrical Systems/Electrical Installations | Billing:monthly | Amount:742000.08
Annual Plan-Vengara Block Panchayath Wiring works to Kariyaram Anganvadi-S0143-26-General Electrical Work
1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
SUB-HEAD- Civil Work including Electrical Work, Sanitary and Plumbing, Water Supply, Sewage and other Allied Works etc.
Supplying, installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS :10322 with driver as per the requirement with Driver efficiency >85%,Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp.range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD 10% , P. F.=0.95, IP20, CRI>80 , UGR (Unified Glare Rating) 19, Flicker free (flicker should be below 5%), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends ,CCT 3000°K / 4000°K / 5700°K / 6000°K / 6500°K (As per ANSI Bin),SDCM (Standard Deviation Color Matching) 3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards and trade mark certificate (T.C.).Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c connections with 1.5 sq mm FRLS,PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy =105 and 120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C)
Provision of Internal Electrification for the newly proposed Seminar Hall at Eighth floor of Anna Centenary Library Kotturpuram Chennai 85
Earthing as per the ISI specification with an earth electrode of 2.10 metre Class 'B' GI pipe of dia not less than 40mm with copper earth plate with necessary funneling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonry SR
Providing Electrical wiring, Electrical light fittings and fans and other connected works for Shifting of office of Sr. CE Civil, TSCZ, Hyd to 9th floor, Door Sanchar Bhavan Hyderabad
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. a) Group C
Annual Plan-Mannur GP - 2025 - 26 - Project No. 120/26 - Installation of Mini Mast light in Kunnath SC Colony-Electrical work-General Electrical Work
Work Name:Annual Plan-Mannur GP - 2025 - 26 - Project No. 120/26 - Installation of Mini Mast light in Kunnath SC Colony-Electrical work-General Electrical Work