Loading…
Loading…
59,318 results • Best match
Repair Renovation of Electrical installation works SERVER ROOM Barrackpore court Existing section office electrical and sub-Division office III at Barrackpore under Barrackpore Electrical Sub-Division, P.W.Dte.
'Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (BrandapprovedbyEIC) in20mmsizePVCrigidconduit 'FR' (Precisionmake), with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVCinsulated&unsheathedcopperwire for ECC, to light/fan/call bell pointswithPianoKey typeswitch fixed on MSCRC sheet metal (16SWG)switch board cum JB on wall complete with 2no.suitable size“Ph&N”copper bar incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. 175mmx100mmx65mm inspectionbox, making earthing attachment, painting the MS box and mending good the damages to original finish (Average run 9 mtr). (18no light point, 2 no fan point, 1no ex fan point, call bel point 1no )
Operation and Maintenance Of Electrical Systems/Electrical Installations - Supply and Laying of LT cable to porta cabins at SP and HST of VEL GARC Chennai
Operation and Maintenance Of Electrical Systems/Electrical Installations - Supply and Laying of LT cable to porta cabins at SP and HST of VEL GARC Chennai
Repair and Renovation work for Psychiatry Department at Burdwan MCH, ----- Electrical Installation work.
Laying of cable as below, after cutting floor/pavement/wall/ and making holes incl., embedding the cable at an average depth as below and mending good the damages to original finish incl. removing the rubbish
GENERAL-Essendene, Cliff House Compound, Nanthancode-Renovation to electrical installation 2026-Ministers Bungalow-EI-General Electrical Work
1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
GENERAL RUNNING CONTRACT WORKS 2025-2026 TIRUR TANUR REST HOUSE Annual Maintenance Works for Emergency and Minor Repair Works in Tirur and Tanur Rest houses in Malappuram District -Electrification-General Electrical Work
Electrification
INSTALLATION AND RENOVATION WORKS OF ELECTRICAL WIRING AND GLOW SIGN BOARD AND OTHER ELECTRICAL RELATED WORKS AT PGM SHAH ROAD AND ADJACENT AREAS IN WARD NO-94, BR-X.
Laying on Wall / surface with Saddles / clamps.(a)Laying of cable upto 2 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (HOT Dip) Wire, making holes etc. as necy. mending good damages and painting