Loading…
Loading…
177 results • Best match
Aerosol based fire detection and suppression system (Electrical)
Description :Supply and installation of Aerosol based fire detection and suppression system cartridge100 gm+100gm, total 2 pieces per coach SBC, technical requirement as per Annexure G-1 of RDSO spec.no. R DSO/PE/SPEC/AC /0192-2018(REV-1) or latest and RDSO letter no. EL/7.1.108/MSSBC dated 17.09.2021 and setting of temperature range as 68-72 degree C for sensing cum Actuating devices as per RDSO letter no. E L/7.1.108/SBC/Main dated 06.08.25 or latest. Revised location of Aerosol based Fire Suppression System as per RDSO letter no RDSO letter no. EL/7.1/.108/MSSBC/Main dated 18.06.2025. All necessary modification cl amping arrangement and accessories required for installation of this item shall be with the scope of this su pplier. Acceptable make: RDSO approved make. [ Warranty Period: 30 Months after the date of delivery ] ] Consignee SSE/AC COACH/GKP, NER Uttar Pradesh 92.00 Set Inspection Details Stage Inspection Not Required
Supply and installation of Aerosol fire detection & suppression system
Description :Supply and installation of Aerosol fire detection & suppression system cartridge 100 gm with Bulb Thermal Actuator/Thermal head having actio n temperature as 68- 72 degree centigrade & as per the technical requirement specified in annexure G-1 of Spec. no. RDSO/ PE/ SPEC/ AC/ 0192-2018 (Rev-1) Make:- Fire pro /Stat-x/ Pyrogen or any RDSO approved make only. [ Warranty Period: 30 Months after the date of delivery ] ] Consignee Sr.Section Engineer /Electrical(Power)-ADI, WR Gujarat 26.00 Numbers Inspection Details Stage Inspection Not Required
Restoration of Fire Alarm system in BEL-Hyderabad
Supplying, installation, testing & commissioning of Smoke detector with base as required.
AMC of Fire Detection Auto Dialer system
Supply & Installation of aerosol fire detection and suppression system
Description :Supply & installation of Aerosol fire detection & suppression system cartridge 15 gm with Bulb Thermal Actuator/Thermal head having action te mperature as 68- 72 degree centigrade & as per the technical requirement specified in annexure G-1 of Spec. no. RDSO/ PE/ SPEC/ AC/ 0192-2018 (Rev-1) Ma ke:- Fire pro /Stat-x/Pyrogen or any RDSO approved make only. [ Warranty Period: 30 Months after the date of delivery ] ] SR. SECTION ENGINEER ( EL/RAC ) AHMEDABAD Gujarat 36.00 Numbers M.G., WR Consignee SR. SECTION ENGINEER ( EL/RAJ-ROE ) AHMEDABAD, Gujarat 18.00 Numbers WR Inspection Details Stage Inspection Not Required
Replacement of Thermocouple Based Fire Detection System with Continuous Loop Fire Detection and Warning System and Modification on 110 Jaguar Aircraft