Loading…
Loading…
17 results • Latest
Supply, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel as replacement of existing old one and allied works at Metriabruz Super Speciality Hospital, District - South 24 pgs.
“Supply, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel as replacement of existing old one and allied works at Metriabruz Super Speciality Hospital, District - South 24 pgs.”(as per Annexure-A)
COAT FOR FIRE PROXIMITY SUIT LARGE AS PER ENCL, COAT FOR FIRE PROXIMITY SUIT MEDIUM A S PER ENCL, COAT FOR FIRE PROXIMITY SUIT SMALL AS PER ENCL, TROUSER FOR FIRE PROXIMITY SUIT LARGE AS PER ENCL, TROUSER FOR FIRE PROXIMITY SUIT MEDIUM AS PER ENCL, TROUSER FOR FIRE PROXIMITY SUIT SMALL AS PER ENCL, BOOT FOR FIRE PROXIMITY SUIT LARGE AS PER ENCL, BOOT FOR FIRE PROXIMITY SUIT MEDIUM AS PER ENCL, BOOT FOR FIRE PROXIMITY SUIT SMALL AS PER ENCL, GLOVES FOR FIRE PROXIMITY SUIT LARGE AS PER ENCL, GLOVES FOR FIRE PROXIMITY SUIT MEDIUM AS PER ENCL, GLOVES FOR FIRE PROXIMITY SUIT SMALL AS PER ENCL, HOOD INNER FOR FIRE PROXIMITY SUIT AS PER ENCL, HELMET WITH SHROUD VISOR FOR FIRE PROX SUIT AS PER ENCL, DIVIDING BREACHING AS PER ENCL, COUPLING DOUBLE FEMALE AS PER ENCL, LUG FOR COUPLING DOUBLE FEMALE AS PER ENCL, SPRING FOR COUPLING DOUBLE FEMALE AS PER ENCL, WASHER FOR COUPLING DOUBLE FEMALE AS PER ENCL, COUPLING DOUBLE MALE AS PER ENCL, EXTINGUISHER FIRE CO2 2 KG SQUEEZE GRIP TYP AS PER ENCL, DISCHARGE HORN FOR EXTINGUISHER FIRE CO2 2 KG AS PER ENCL, HOSE FOR EXTINGUISHER FIRE CO2 2 KG AS PER ENCL, 09 KG DCP EXTINGUISHER ABC TYPE AS PER ENCL, HOSE FOR 09 KG DCP EXTINGUISHER AS PER ENCL, TRIGGER CONT NOZZLE FOR 09 KG DCP EXTINGUISHER AS PER ENCL, WASHER FOR 09 KG DCP EXTINGUISHER ABC TYPE AS PER ENCL, CO2 CARTRIDGE FOR 09KG DCP EXTINGUISHER ABC AS PER ENCL, ABC DRY POWDER 10KG BAG FOR 09KG DCP EXTINGUISH AS PER ENCL, EXTINGUISHER DRY POWDER 75 KG TROL MOUNT EXT AS PER ENCL, PVC NYLON BRAID HOSE FOR EXTINGUISR DRY POWDER AS PER ENCL, NOZZLE FOR EXTINGUISR DRY POWDER 75KG AS PER ENCL, WASHER FOR EXTINGUISR DRY POWDER 75KG AS PER ENCL, DISCHARGE VALV FOR EXTINGUISR DRY POWDER 75KG AS PER ENCL, 9 LITRE AFFF EXTINGUISHER AS PER ENCL, CO2 CARTRIDGE 60GM FOR 9LITRE AFFF EXTINGUISHR AS PER ENCL, 08 MM DIA 1 M LENGTH PVC NYLON BRAIDED HOSE AS PER ENCL, NOZZLE FOR 9 LITRE AFFF EXTINGUISHER AS PER ENCL, WASHER FOR CAP FOR 9 LITRE AFFF EXTINGUISHER AS PER ENCL, SPRING FOR 9 LITRE AFFF EXTINGUISHER AS PER ENCL, EXTINGUISHER TWIN 6.5 KG CO2 PORTA TROL MK II AS PER ENCL, HOSE FOR EXTINGUISHER TWIN 6.5 KG CO2 AS PER ENCL, NOZZLE FOR EXTINGUISHER TWIN 6.5 KG CO2 AS PER ENCL, DISCHARGE HORN FOR EXTINGUISHER TWIN 6.5KG CO2 AS PER ENCL, FOAM LIQUID AFFF 20 LTR PLASTIC CONTAINER AS PER ENCL, FIRE COAT MEDIUM FOR FIRE FIGHTER SUIT AS PER ENCL, FIRE COAT SMALL FOR FIRE FIGHTER SUIT AS PER ENCL, TROUSER MEDIUM FOR FIRE FIGHTER SUIT AS PER ENCL, TROUSER SMALL FOR FIRE FIGHTER SUIT AS PER ENCL, RUBBER BOOTS FOR FIRE FIGHTER SUIT SIZE 9 AS PER ENCL, RUBBER BOOTS FOR FIRE FIGHTER SUIT SIZE 8 AS PER ENCL, GLOVES FOR FIRE FIGHTER AS PER ENCL, ANTIFLASH HOOD FOR FIRE FIGHTERS AS PER ENCL, HELMET WITH HEAD LAMP FOR FF AND DC AS PER ENCL, FB 10 X FOAM MAKING BRANCH PIPE, INLINE FOAM INDUC PICK UP ASSLY FOR FB 10 X AS PER ENCL, FB 5 X FOAM MAKING BRAN PIPE WITH ASSLY AS PER ENCL, HOSE IMPERMABLE WITH INSTANTANEOUS COUPLING AS PER ENCL, BATTERY AA ALKALINE 1.5V LR 6 AS PER ENCL, VARIABLE DELIEVERY NOZZLEV AS PER ENCL, HOSE IMPERMABLE WITH INSTANTANEOUS COUPLING 38MM DIA X 15 M
FIRE FIGHTING ITEMS
FIRE EXTINGUISHER, Fire Bucket, Shovel GS, PICKUP AXE, Fireman AXE, Fire Beater, Fire Ball 1.3kg MAP 90, AFFF 50 LTR, FIRE ETINGUISHER, Extention LADDER 7.5FT, CROWBAR
FIRE FIGHTING ITEMS
SITC of IFDS _Fire Detection system_ at Chandi Doulatabad RH in the District of South 24 Parganas.
FIRE CONTROL PANEL Supply, Installation, Testing & Commisioning of Microprocessor based Intelligent, addressable expandable, opc complied and fully networkable FireAlarm Control Panel (VDS/UL/ERTL, LPCB & FM approved) suitable for the devices as stated below along with 20% spare capacity with each loop loading not exceeding 80% of the full capacity of detectors and devices taken together in addition the panel should have the provision for addressing 200 devices/detectors for future uses of proposed additional two vertical floors, conplying to IS 2189:2008 or its latest amendments, and with minimum 600 character alpha - numeric liquid crystal display. The panel shall be soft addressable type and shall be able to give pin point location of all fire/fault conditions. Further, the panel must be able to automatically switch off respective control switches whenever any alarm is triggered. The Panel should be able to store sufficient numbers of log events in its Memory as per recommended standards. a) The panel shall have in built rectifier, provision for external & internal printer (if required), Loop cards, LCD unit to indicate Fire/Fault Signal with address and analog output, complete in all respects, in built Surge protection facility, integral SMF lead acid batteries with scaled cells of 24 V capable of running for 24 hours normal working and then be capable of operating the system for 30 minutes during Emergency condition, with integral battery charger complete in all respect as required. b) The FACP shall be capable of being networked (future expansion) with other similar FACP located at different part of the premises through single RS 485 bus. The FACP shall have provision for interfacing with the public address system, remote computer and BMS interface. The system must be preloaded with licenced software. (Approved Make: Esser/Cerberus Pro/Bosch/ Johnson Controls/Notifer/Edward/Secutron/Securiton/Apollo /Morley/Eaton/GST/GFE) c) NOTE: 1. The Fire Alarm system shall comply with latest requirements of -- 2. National Fire Protection Association (NFPA) Standards IS:2189. 3. NFPA 70 National Electric Code. 4. NFPA 72 National Fire Alarm & Signaling Code. 5. Local Statutory Regulations. 6. Manufacturer Recommendation d) TESTS: 1.The system shall be tested and commissioned by a qualified competent, trained engineer or technician authorized by the manufacturer of the fire alarm equipment to technically supervise and participate during all of the adjustments and tests for the system. 2. Before energizing the cables and wires, check for correct connections and test for short circuits, ground faults, continuity, and insulation and other tests as per above standards must be done. 3. The Commissioning Manuals, Tools, Dongles, USb Token, Software, or whatever is required for the Commissioning of the FACP, in whatever name it called must be handed over to the EIC, along with the passwords of the panel.
Refilling and HPT of Fire Extinguishers at our DRT/CFS site
Urgent restoration of Fire Protection System in different buildings of MJN Medical College, Coochbehar in the Year 2025,2nd call
Urgent restoration of Fire Protection System in different buildings of MJN Medical College, Coochbehar in the Year 2025(2nd call)