Loading…
Loading…
1,560 results • Best match
Airway long transparent Oropharyngeal set consisting of size 0 1 2 3 4, Adhesive Incise drape 25x30cm, Adhesive Incise drape 5x15cm, Apparatus Anaesthitic face Mask with air cushion transparent size 0 infant, Apparatus Anaesthetic facemask with air ... for pulse oximeter ... for pulse oximeter, ...
Finger Probe for pulse oximeter Adult and paediatric Finger Probe for pulse oximeter, Adult & paediatric
Emergency Procurement of Pharmaceutical Products Consumables and Medical Equipments for Onward Supplies to Foreign Country
Pulse Oximeter
52-26284-Star-Delta-Timer, 52-32188-On-delay-Electronic- Timer, 52-5520-Universal-Temperature-Controller, 52- 5525-DIGITAL-DISPLAY-PRESET-COUNTER, 52-23824- Universal-Temperature-Controller, 52-5524-Universal- Temperature-Controller, 52-98908-Digital-Multifunction- Timer, 52-98916-Interval-Electronic-Timer
52-98908-Digital-Multifunction-Timer Digital Multifunction Timer with Instant Contact Up Counting Source Voltage 24 to 240 plus or minus 10 percent V AC or DC 50 Hz Time Range 0 point 1 Sec to 99 Hrs 59 Min Output 1 instant and 1 delayed or 2 delayed Hold or Restart facility during power failure condition Digital Display for set value and Process value Program enable and disable facility On delay or Interval or cyclic selectable Start Signal No start or pulse or continuous Dimension 48 x 48 mm
Supplying, Installation, Testing and Commissioning of Electrical Control Engg. lab, Analog and Digital Electronics and Microprocessor Lab Setup at TTAADC Polytechnic Institute, Khumulwng, West Tripura
Function Generator 5 MHz (with Frequency Counter 30MHz Technical Specification:- Frequency Range : 0.1Hz-5MHz Output / Waveform : Sine, triangle, Square positive & negative Pulse Positive & Negative ramp Output impedance : 50 Ohms ± 10% Amplitude : Not Less than 20V p-p (Open Circuit) DC Voltage : 0-± 10V Continuously Adjustable Symmetry Range : 90:10-10:90 Attenuation : 20dB, 40dB, 60dB Rising Edge of Square : 100ns Sine Characteristics: 1% at 10Hz-100KHz Distortion: Frequency Response : 0.1Hz 100kHz : ± 0.5dB, 100kHz 5MHz : ± dB TTL / CMOS Output level : TTL Low level less than 0.4V in pulse wave less than 3.5V. CMOS low level than 0.5V Pulse wave, high level 5V-14V continuously variable Rising Time : 100ns VCF Input:,Output Voltage : -5V-0V ± 10% Max. Volt-Controlled : 1000:1 Input Signal : DC-1KHz Frequency Counter: Measuring Range : 1Hz-30MHz Input impedance : Not less than 1Mohms 20pF Sensitivity : 100mV rms Max. Input : 150V(AC+DC) Input Attenuation : 20dB Accuracy : less than 0.003% ± 1 digit Power Supply : 230V ± 10%, 50Hz Standard Accessories: Power Cable, BNC to Crocodile Clip Probes-1 No. & BNC to BNC Probe-1 No., Instructional Manual
Sodium 0 point 1 mg, Alendronate Sodium 70 mg Tab, Brimonidine Tartrate 0 point 2 percent Eye Drop, Bimatoprost 0 point 03 percent bott of 3ml, Azelastine HCL 140 mcg plus Fluticasone Propionate 50 mcg BP Nasal spray, Tab Betahistine Dihydro Chloride ... dose supplies 50mcg ... Turpentine oil 15 ... containing milk of ...
Levosalbutamol Aerosol inhalation pack of 200 metered dose each metered dose supplies 50mcg of levosalbutamol
Supplying Public Health materials for Annual Maintenance in Melpattampakkam Town Panchayatfrom 01-04-2026 to 31-03-2027
Pulse oximeter