Breathing Air Compressor , Water Turbine High Expansion Generator
Proposed Horizontal and Vertical Extension upto (G9) with provision of 10 storied of LINAC Building (G2) for Chest and Cancer Dept. of IPGMER - SSKM Hospital, Kolkata --Electrical Works -- SITC of Silent Diesel Generator set.
MODBUS / Ethernet connectivity should be provided for display of engine parameters such as Engine RPM, Running Hour, Fuel consumption, Engine Water Temperature (Analog and Digital for Alarm) Oil Pressure (Analog and Digital for Alarm), Engine Overspeed (DI), Sensor Failure (DI), Battery Charging (DI), Battery Voltage (AI), Low Battery Alarm (DI), Fuel Level (Low, Medium, Full - all DI), Mains On (DI), DG On (DI), Current in each phase and Neutral (AI), Generator Voltage in each Phase (AI), Generator Frequency (AI), PF (AI), Energy (AI) etc. Address Map should be provided at the time of commissioning. Necessary programming/ configuring (setting of device address, Baud Rate, Parity etc. for Modbus and IP address for Ethernet) at DG controller/ control panel end, should be done by the OEM for setting up connectivity with the existing 3rd party SCADA at no extra cost. Network cable termination at DG end should be done by the OEM
Proposed (G plus 9) storied Private Cabin Building within the premises of IPGMER- SSKM Hospital, Kolkata -- Electrical Installation Works Other Utility Services --- SITC of Silent DG Set with allied installation work .
MODBUS / Ethernet connectivity should be provided for display of engine parameters such as Engine RPM, Running Hour, Fuel consumption, Engine Water Temperature (Analog and Digital for Alarm) Oil Pressure (Analog and Digital for Alarm), Engine Overspeed (DI), Sensor Failure (DI), Batter Charging (DI), Battery Boltage (AI), Low Battery Alarm (DI), Fuel Level (Low, Medium, Full - all DI), Mains On (DI), DG On (DI), Current in each phase and Neutral (AI), Generator Voltage in each Phase (AI), Generator Frequency (AI), PF (AI), Energy (AI) etc. Address Map should be provided at the time of commissioning. Necessary programming/ configuring (setting of device address, Baud Rate, Parity etc. for Modbus and IP address for Ethernet) at DG controller/ control panel end, should be done by the OEM for setting up connectivity with the existing 3rd party SCADA at no extra cost. Network cable termination at DG end should be done by the OEM
Electrical work for Construction of Seven storied building for Institute of Neuroscience seven storied foundation), along two storied Electrical Sub-station building three storied foundation and Canteen building - SITC of Diesel Generator Set.
MODBUS / Ethernet connectivity should be provided for display of engine parameters such as Engine RPM, Running Hour, Fuel consumption, Engine Water Temperature (Analog and Digital for Alarm) Oil Pressure (Analog and Digital for Alarm), Engine Overspeed (DI), Sensor Failure (DI), Battery Charging (DI), Battery Voltage (AI), Low Battery Alarm (DI), Fuel Level (Low, Medium, Full - all DI), Mains On (DI), DG On (DI), Current in each phase and Neutral (AI), Generator Voltage in each Phase (AI), Generator Frequency (AI), PF (AI), Energy (AI) etc. Address Map should be provided at the time of commissioning. Necessary programming/ configuring (setting of device address, Baud Rate, Parity etc. for Modbus and IP address for Ethernet) at DG controller/ control panel end, should be done by the OEM for setting up connectivity with the existing 3rd party SCADA at no extra cost. Network cable termination at DG end should be done by the OEM
Generator ASSY (1812005307), STARTER ASM (1811003413)
Generator ASSY (1812005307)
1. Signalling arrangements at byepass cabin and at Parli station in connection with proposed byepass cabin at Parli station for connecting Latur Road-Parli vaidyanath & Parli vaidyanath- Parbhani Main lines. 2. Signalling arrangements at Y connection cabin and at Laturu Road station in connection with proposed Y connection at Latur Road station for connecting Latur Road-Parli vaidyanath & Laturu Road - Kurudwadi Main lines. 3. Signaling arrangements at proposed new crossing station between KMNR-UDGR stations.