Loading…
Loading…
227 results • Best match
Building works/ Building maintenance works with structural steel and Metal Sheet roofing items.
Supplying and fixing following size uPVC UV-Stabilised soil / waste quality pipes and fittings ( SWR ) for soil, waste, vent, anti syphonage, HVAC waste pipe and rain water pipe lines consisting following items of work:- i) Providing and fixing uPVC UV-Stabilised Soil/ waste pipe as per IS:13592 and IS:14735 Type-B laid in floor & on Exposed faces of wall of approved make. ii) Fixing the pipeline vertically by Metal clamps with rubber seal of approved make iii) Fixing the pipeline Horizontaly with specified slope below the ceiling by Metal clamps with rubber seal and GI hanger rods not less than 5mm dia at specified spacing, including all required hardware. iv) Providing and fixing uPVC cowl at the top of soil, waste water & vent pipe line. v) Providing and fixing uPVC P/S trap on line as per requirement for soil,waste water pipeline. vi) Laying the pipe below floor / ground to the slope and gradient equal to (or) steeper than 1 in 50, making leak proof connections of soil /waste pipe line from the shaft with inspection chamber / Manhole / Gully trap Chamber including the cost of filling around the holes of inspection chamber / Manhole / Gully trap with cement mortar 1:1 mixed with water proofing compound vii) Jointing the pipe / fittings with Solvent Cement & Rubber ring gasket with making holes in walls / floor grooving and redoing the same and brick support etc. Carrying out water-tightness test for the pipes laid as per codal provisions. Providing Ring Joint pipes at verticals and solvent cement jointed pipes at concealed locations. viii) Cutting the pipe to the required length including providing short pieces, necessary connectors, fittings & specials with & without door, assorted fittings such as plugs, tees, couplers, reducers, cross tees, reducing tees, elbows, bends, single & double Y, vent cowl, gaskets, offsets etc. including providing necessary clean outs, cleaning pipe, extension pipe if any for clean outs, door bend, door elbow, door Y, socket plug, etc wherever required for accessing every segment of soil and waste pipes to enable removal of any Chock up after installation. ix) Providing necessary specials for connecting UPVC SWR (IS:13592/ IS:14735) pipe with UPVC (IS:4985) pipe etc x) Dewatering the pit/ trenches if necessary till completion of work xi) Testing the pipe line for any leakages, rectifying the leakages if any, retesting etc., till water tightness of the pipe line is ensured. xii) Exposed pipe fixing arrangement include slotted G.I. section and U clamps. Note: Earthwork excavation for trenches shall be paid under relevant items For Soil & waste, Vent and Rain water pipe lines
CONSTRUCTION OF RIVERSIDE SAVORIESI.E. BUILDING WITH UNDERGROUND ROAD BETWEEN NEHRU BRIDGE AND ELLISBRIDGE AND CONSTRUCTION OF PUBLIC PLAZA AND UNDERGROUND PARKING FACILITY AT SANSKAR KENDRA - TAGORE HALL CAMPUS CONNECTING RIVERFRONT ON WESTBANK FOR SRFDCL.
B Electrical & ELV, HVAC Work
Construction of ORs living accommodation Kitchen and dining hall and Construction of Boundary wall Main Gate Guard room Sentry post at Tadadege BOP of 57th BN ITBP
Supplying, Unloading, shifting, Installation at proposed location, testing and commissioning of LT Panel size 4'6"x3'x1' and frame 16 SWG fully powder coated/enamel painted after seven tank treatment. This will be floor mounted/wall mounted, double door, out door duty, dust proof, vermin proof, front operated, electrical panel fabricated as per specifications laid in this document and will be complete with the main and auxiliary bus bars, interconnection, earth bus and will be powder coated finish with 70 micron thickness. The HVAC Panel shall use all MCCB's suitable for 415 V AC, 3 phase, 50 Hz, 3 phase 4 wire supply system. Each incoming breaker will have microprocessor based releases and all outgoing breaker will have minimum electrostatic releases. The Panel will be made as per detailed specifications & drawings forming part of this document. (Each MCCB will be variable current setting from front, with front extended lockable handle, pad lockable in off position, indication light for ON, shrouding on incomer side, termination shall be suitable for aluminium bus bars.) Incomer:- A) 1 No 100A TPN feeder each having one no 100A 4P MCCB 38 KA B) 1 No volt meter with selector switch 3 nos indicating lights C) 1 No Ampere meter with selector switch, matching CT's. D) TPN Aluminium bus bar rated for 300A (after considering all necessary deratings) 3 phase 4 wire, 50Hz. A minimum derating factor of 0.66 must be taken for calculation of bus bar sizes. The bus bar size after derating shall be equal to the ampere given in the BOQ The conductivity of bus bar shall not be less than 58% and earth bus size shall be 10% of phase bus bar. Outgoings:- A) 2 Nos 63A TPN feeder each having one no. 63A 4P MCCB 38 KA B) 2 Nos 40A TPN feeder each having one no. 40A 4P MCB 38 KA C) Set of suitable load capacitor bank , Other items such as Lot of control wiring, 1 Set of designation plates
Construction of MT Shed at Henkar BOP of 57th Bn ITBP
Supplying, Unloading, shifting, Installation at proposed location, testing and commissioning of LT Panel size 4'6"x3'x1' and frame 16 SWG fully powder coated/enamel painted after seven tank treatment. This will be floor mounted/wall mounted, double door, out door duty, dust proof, vermin proof, front operated, electrical panel fabricated as per specifications laid in this document and will be complete with the main and auxiliary bus bars, interconnection, earth bus and will be powder coated finish with 70 micron thickness. The HVAC Panel shall use all MCCB's suitable for 415 V AC, 3 phase, 50 Hz, 3 phase 4 wire supply system. Each incoming breaker will have microprocessor based releases and all outgoing breaker will have minimum electrostatic releases. The Panel will be made as per detailed specifications & drawings forming part of this document. (Each MCCB will be variable current setting from front, with front extended lockable handle, pad lockable in off position, indication light for ON, shrouding on incomer side, termination shall be suitable for aluminium bus bars.) Incomer:- A) 1 No 100A TPN feeder each having one no 100A 4P MCCB 38 KA B) 1 No volt meter with selector switch 3 nos indicating lights C) 1 No Ampere meter with selector switch, matching CT's. D) TPN Aluminium bus bar rated for 300A (after considering all necessary deratings) 3 phase 4 wire, 50Hz. A minimum derating factor of 0.66 must be taken for calculation of bus bar sizes. The bus bar size after derating shall be equal to the ampere given in the BOQ The conductivity of bus bar shall not be less than 58% and earth bus size shall be 10% of phase bus bar. Outgoings:- A) 2 Nos 63A TPN feeder each having one no. 63A 4P MCCB 38 KA B) 2 Nos 40A TPN feeder each having one no. 40A 4P MCB 38 KA C) Set of suitable load capacitor bank , Other items such as Lot of control wiring, 1 Set of designation plates
Improvement of (RandB) Division office building and conference room at Angul for the year 2025-26. (Civil, EI, PH).
NB:All the electrical,Fire fighting,HVAC,ELV drawings, Technical Data Sheets & make will be approved by SE R& B Electrical circle & CE Building ,Odisha ,Bhubaneswar prior to execution of the work.
Construction of Canteen with necessary furniture (Chair and Tables) at B Block of Bangla Bhawan, Chanakyapuri, New Delhi during the year 2026.27.
S & Installation of Extra Add-on items- HVAC grade 5/8" (for suction) & 1/4" (for discharge) copper refrigerant pipe with 9 mm thick nitrile rubber insulation including shaddle, screws, insulation tape, fasner etc. for above AC machines as per direction of EIC.