Loading…
Loading…
55 results • Latest
Providing and Fixing Inlet Structure of MS at Diff Lakes in Sarkhej ward in South West Zone
performance valves suitable for industrial applications, particularly those
Repairing of Diff. Size Kinfe Edge Gate Valve of Lakes at Sarkhej ward in South West Zone
performance valves suitable for industrial applications, particularly those
Repairing & Raising of MH/CH/CP & Replace seat covers With Daimond Cutting Method at TP-85 area,sarkhej gamtal area & Other Diff. Lacation of Sarkhej ward in South West Zone.
j) Industrial Disputes Act 1947:- The Act lays down the machinery and procedure for resolution of
Refilling of Medical Gases in Cylinders
Refilling of Medical Gases in Cylinders
Imaging Equipments & Cardio Pulmonary equipments for Kampli new 100Beds Taluka Hospital, Ballari District under 2515-KKRDB (Macro projects) for the year 2024-25
6 Item-6 CENTRAL SUPPLY OF 02, N20, VACUUM.. Central Oxygen system INSTALLATION erection& TESTING Installation of medical gas piping shall be carried out with utmost cleanliness. Only pipes, fittings and valves which have been de-greased and fittings brought in polythene sealed bags shall be used at site. Pipe fixing clamps shall be of nonferrous or no deteriorating plastic suitable for the diameter of the pipe. All joints shall be made of copper to copper and brazed by silver brazing filler material without use of any flux. All brazing shall be done by using a brazing rod CP 104 (5% silver copper phosphorous brazing alloy) and copper-to-brass or gunmetal shall only be joints using brazing rod AG 203 (43% Silver-copper-zinc-brazing alloy) manufactured to EN-1044. Inert gas welding technique should be used by oxygen free Nitrogen gas inside copper pipes while brazing to avoid carbon deposition. 1. OXYGEN SYSTEM Main Oxygen Manifold 10 x 10 cylinders with NRV's, Tail pipes and Middle frame ------SET 1 automatic Oxygen Control Panel (indigenous) with automatic changeover from Running Bank to Reserve Bank of cylinders and having non-halogenated polymer in the high pressure side of the primary regulators and 40 micron inlet filter.---1 No 2. COPPER PIPING AS PER EN 13348 WITH THIRD PARTY - Copper Pipe for Medical use with 15 OD X 1.0 mm --- Approximately 1250 mtrs( original as per measurements) 3. FACTORY DEGREASED ISOLATION VALVES FOR MEDICAL USAGE WITH BRASS ADOPTERS 1. Isolation Valve for 15 mm Copper Pipe i.e (1/2")--- 30 no 4. MEDICAL GAS OUTLETS. DIN type ,Double Lock with probe – Oxygen ---50 No 5. . Oxygen Flowmeter BPC (0- 15 LPM) with Humidifier Set---50 No Bed Headed Panel and Railing.---15 No Double railing Bed head panels Should have bellow Specifications .Accessories 1. IV Stand Extendable type with aluminum slider. 2. Monitor stand wall Panel mounted. 3. Ward vacuum unit slider. 4. Two duplex 230 V, 5/15 Amp. Electrical Sockets Provision Gas/Vacuum outlets as follows. Two oxygen outlet. One Vacuum outlet central vacuum pipe line system Vacuum Supply System: Each 1.00 4956906.24 4956906
Hospital furniture & Accessories for Kampli new 100 Beds Taluka Hospital, Ballari District under 2515-KKRDB (Macro projects) for the year 2024-25
6 Item-6 CENTRAL SUPPLY OF 02, N20, VACUUM.. Central Oxygen system INSTALLATION erection& TESTING Installation of medical gas piping shall be carried out with utmost cleanliness. Only pipes, fittings and valves which have been de-greased and fittings brought in polythene sealed bags shall be used at site. Pipe fixing clamps shall be of nonferrous or no deteriorating plastic suitable for the diameter of the pipe. All joints shall be made of copper to copper and brazed by silver brazing filler material without use of any flux. All brazing shall be done by using a brazing rod CP 104 (5% silver copper phosphorous brazing alloy) and copper-to-brass or gunmetal shall only be joints using brazing rod AG 203 (43% Silver-copper-zinc-brazing alloy) manufactured to EN-1044. Inert gas welding technique should be used by oxygen free Nitrogen gas inside copper pipes while brazing to avoid carbon deposition. 1. OXYGEN SYSTEM Main Oxygen Manifold 10 x 10 cylinders with NRV's, Tail pipes and Middle frame ------SET 1 automatic Oxygen Control Panel (indigenous) with automatic changeover from Running Bank to Reserve Bank of cylinders and having non-halogenated polymer in the high pressure side of the primary regulators and 40 micron inlet filter.---1 No 2. COPPER PIPING AS PER EN 13348 WITH THIRD PARTY - Copper Pipe for Medical use with 15 OD X 1.0 mm --- Approximately 1250 mtrs( original as per measurements) 3. FACTORY DEGREASED ISOLATION VALVES FOR MEDICAL USAGE WITH BRASS ADOPTERS 1. Isolation Valve for 15 mm Copper Pipe i.e (1/2")--- 30 no 4. MEDICAL GAS OUTLETS. DIN type ,Double Lock with probe – Oxygen ---50 No 5. . Oxygen Flowmeter BPC (0- 15 LPM) with Humidifier Set---50 No Bed Headed Panel and Railing.---15 No Double railing Bed head panels Should have bellow Specifications .Accessories 1. IV Stand Extendable type with aluminum slider. 2. Monitor stand wall Panel mounted. 3. Ward vacuum unit slider. 4. Two duplex 230 V, 5/15 Amp. Electrical Sockets Provision Gas/Vacuum outlets as follows. Two oxygen outlet. One Vacuum outlet central vacuum pipe line system Vacuum Supply System: Each 1.00 4956906.24 4956906