24 results • Latest
Expression of Interest for Robotic Surgery System
D Model Name / Model No. of the Equipment (If the equipment is a combination of more than one equipment then list down the model no. pertaining to each): Make:
Imaging Equipments & Cardio Pulmonary equipments for Kampli new 100Beds Taluka Hospital, Ballari District under 2515-KKRDB (Macro projects) for the year 2024-25
ESTIMATE FOR IMAGING EQUIPMENTS & CARDIO PULMONARY EQUIPMENTS FOR KAMPLI NEW 100 BEDS TALUKA HOSPITAL
Hospital furniture & Accessories for Kampli new 100 Beds Taluka Hospital, Ballari District under 2515-KKRDB (Macro projects) for the year 2024-25
Imaging Equipments & Cardio Pulmonary equipments for Kampli new 100Beds Taluka Hospital, Ballari District under 2515-KKRDB (Macro projects) for the year 2024-25 (PWD/2025-26/IND0201)
Labour ward, Neonatal Opthalmic equipments for Kampli new 100 Bed Taluka Hospital, Ballari District under 2515-KKRDB (Macro projects) for the year 2024-25
Imaging Equipments & Cardio Pulmonary equipments for Kampli new 100Beds Taluka Hospital, Ballari District under 2515-KKRDB (Macro projects) for the year 2024-25 (PWD/2025-26/IND0201)
Laboratary, Surgical & PMR equipments for Kampli new 100 Beds Taluka Hospital, Ballari District under 2515-KKRDB (Macro projects) for the year 2024-25
Imaging Equipments & Cardio Pulmonary equipments for Kampli new 100Beds Taluka Hospital, Ballari District under 2515-KKRDB (Macro projects) for the year 2024-25 (PWD/2025-26/IND0201)
Blood testing & Office stationary related equipments for Kampli new 100 Beds Taluka Hospital, Ballari District under 2515-KKRDB (Macro projects) for the year 2024-25
23 URINE AUTOANALYZER. 1. The analyser should be compact benchtop, Semi automated integrated urine analyzer, integrating urine chemistry and urine sediment analysis. 2. Chemistry parameters required to be provided should be glucose, protein, blood, bilirubin, urobilinogen, ph, ketones, nitrate, leuokocyte, creatinine & albumin. 3. Additional instrument parameters should have specific gravity, turbidity & colour. 4. The analyser should be based on fluorescence flowcytometry/ Digital flowcytometry for accurate measurement of urine parameters such as rbc, wbc, epithelial cells, cast and bacteria. 5. The instrument should provide scattergrams and histograms or actual images for easy interpretation. 6. The analyser should provide additional rbc information, uti information and conductivity. 7. The analyser should have user friendly software with cross check function. 8. The analyser should have a throughput 50-100 samples / hour (chemistry) & 50 samples / hour (sediment analysis). 9. The equipment should have a storage of 50-200 test strips at a time with continuous loading for true walkaway analysis. 10. The equipment should be capable of analysis in both manual and sampler mode. 11. Sampler should have the capacity of 25-60 sample tubes and internal barcode for sample identification 12. Controls should be available for both chemistry and sediment analysis.