Loading…
Loading…
2,522 results • Best match
Materails only for 80 mm bore GI tubing, Materails only for 50 mm bore GI tubing, Materails only for 40 mm bore GI tubing, Materails only for 25 mm bore GI tubing, Materails only for 20 mm bore GI tubing, Materails only for 50 mm bore gate valve, Materails onlyfor 40 mm bore gate valve, Materails only for 25 mm bore gate valve, Materails only for 20 mm bore gate valve, Materails only for 25 mm diaBall valves high pressure of PTMT, Materails only for 20 mm diaBall valves high pressure of PTMT, Ganti Pickaxe With handle not less than 2Kg with smooth handle 3mtr, Manning and operation at various Pump Houses installations of Zone 04 under EIC Etc., Heavy Duty Pipe Wrench as per IS 4003 (Q3), Ratchet Pipe Threader for Taper Pipe Threads as per IS 16176 (Q3)
Materails only for 25 mm diaBall valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 15mm 142gms/m 2 0 m m 2 1 0 g m s . / 25mm 455gms/ 40mm 690 gms)
Materails only for 80 mm bore GI tubing medium grade laid in trenches walls, Materails only for 50 mm bore GI tubing medium grade laid in trenches walls, Materails only for 40 mm bore GI tubing medium grade laid in trenches walls, Materails only for ... gun metal class ... gun metal class ... gun metal class ... gun metal class ...
Materails only for 25 mm diaBall valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 15mm 142gms/m 2 0 m m 2 1 0 g m s . / 25mm 455gms/ 40mm 690 gms)
Supply of welding items for PMT as per ANNEXURE I. on as and when required basis
Welding cable (Copper)
Supply & testing of 500 KVA, 11KV/750V, 3-phase, 50 Hz. Outdoor type Power Transformer.
Description :Supply & testing of 500 KVA, 11KV/750V, 3-phase, 50 Hz. Outdoor type Power Transformer C onforming to 15 2026 (Part 1): 2011 (Reaffirmed 2021), Plinth Mounted, Copper Wound, Mineral Oil Immers ed with Freely breathing system (also called conservator system) as per Clause 8.2 (a) of IS 2026 (Part 1), Primary Winding in Delta and Secondary Winding in Star (Vector symbol-Dyn11), ONAN Cooled Transformer , Minimum Short Circuit Impedance of 5% as per IS 2026 (part 5), with all Fittings specified in Annexure A t o this Description, Terminal arrangement: The transformers shall be fitted on high voltage and low voltage sides with outdoor type bushings of appropriate voltage and current ratings. The high voltage bushings (3 Nos.) shall confirm to IS/IEC 60137. The low voltage bushings (4) Nos.) shall conform to 15.7421. Suitable c able-end box is to be provided as follows: a) For Outdoor type: L.T. side Tap changer: On-Load Tap changer for variation of HV Voltage from -+5% to -5% in steps of 1.25% Make- Andrew Yule/AEG/Crompton Greaves/ Kirloskar electric Co./ABB/Siemens/Schneider or similar. [ Warranty Period: 30 Months after the date of d elivery ] ] Consignee SSEE/G/TATA, SER Jharkhand 2.00 Numbers Inspection Details Stage Inspection Not Required
Supply and Installation of Precision AC System
3 Core x 2.5 Sq mm Flexible Copper Cable See Annexure - I
Urgent Repairing of Lift Fire Detection system and Electrical Installation Work at Chest and Cancer Building in the premises of IPGMER_SSKM Hospital, Kolkata_S and D of Materials for Fire Detection System
Supply & delivery of 2 Core 1.5 sq.mm FRLS shielded copper Cable (For Loop) (Make. RR Kable / KEI/ Polycab ) & 20 mm NB PVC rigid conduit pipe(Make: Precisson-Medium) on the surface of the wall.