Loading…
Loading…
30 results • Latest
E-TENDER FOR ANNUAL COMPREHENSIVE MAINTENANCE CONTRACT & RATE CONTRACT FOR CONSUMABLE OF PHOTO COPIER MACHINES FOR VARIOUS DEPARTMENT OF AMDAVAD MUNICIPAL CORPORATION
he will be liable to pay the difference amount to the AMC, which AMC has to pay
Supply, Installation, Testing, and Commissioning (SITC) of 200 Nos. of Feedback Machines Across Various Toilet Blocks in Ahmedabad City, along with Five (05) Years of Maintenance Services.
Order/Purchase Order as / Schedule bank/Banks mentioned in AMC circular,
Automatic Tissue Processor, Qty. 01 no. for Histopathology, TMH
Should perform preventive maintenance (2nos) during warranty,AMC,CMC & if entered into AMC(includes unlimited breakdown calls) /CMC (which will include spare replacement, breakdown calls). Vendor to submit SOPs for PMS at the time of installation/ commissioning. This is mandatory requirement.
Customized AMC/CMC for Pre-owned Products - AS PER ATC SL NO 1 IN PRICE BID FORMAT; AS PER ATC SL NO 1 IN PRICE BID FORMAT; Annual Maintenance Contract (AMC); Monthly; Yes, Customized AMC/CMC for Pre-owned Products - AS PER ATC SL NO 2 IN PRICE BID FORMAT; AS PER ATC SL NO 2 IN PRICE BID FORMAT; Annual Maintenance Contract (AMC); Monthly; Yes
Customized AMC/CMC for Pre-owned Products - AS PER ATC SL NO 1 IN PRICE BID FORMAT; AS PER ATC SL NO 1 IN PRICE BID FORMAT; Annual Maintenance Contract (AMC); Monthly; Yes
Hospital furniture & Accessories for Kampli new 100 Beds Taluka Hospital, Ballari District under 2515-KKRDB (Macro projects) for the year 2024-25
4 Item-4 ECHOCARDIOGRAM /2D3D/4D, Description of Function 1.1 Colour Doppler Echocardiography System is required to study the anatomical abnormalities and blood flow in the heart and associated vessels. 2 Operational Requirements 2.1 Latest generation Electronic Phased array Colour Doppler system with Minimum 50,000 digital processing channels with LIVE 3D imaging. System should be DICOM ready and capable of being interfaced with HIS/RIS/PACS. 2.2 Should be field up gradable to next generation system on site. All new software should be upgraded free of cost for at least 7 years 2.3 Frequency compounding or better technology for better resolution and penetration. 3 Technical Specifications 3.1 Latest generation Electronic Phased array Colour Doppler system with Minimum 50,000 digital processing channels with LIVE 3D imaging. 3.2 256 grey shades for sharp contrast resolutions 3.3 Adult & Paediatric Trans thoracic Cardiac, TEE (Adult & Paediatric) and Vascular Probes to be supplied which should belatest generation wide band transducers. 3.4 Harmonic Imaging- System should have following modes in harmonic with separate setting for: a. Tissue Harmonic. b. Contrast Harmonic c. Harmonic Angio. d. Quantification of harmonics imaging 3.5 Harmonic imaging capability in Adult Cardiac, Paediatric Cardiac and linear Probe 3.6 Gain control in two dimensions for additional level of flexibility to image quality control. 3.7 Real time high frequency 2D for higher resolution and low frequency Doppler for higher sensitivity in all probes. 3.8 Frame rate should be 300 FPS or more 3.9 Steerable PW/CW in all Phased Array probes. 3.10 High-definition acoustic zoom for enlarging sections of 2D and Colour flow images with more acoustic information for greater clarity and detail while maintaining an optimal frame rate. 3.11 Modes - 3D, 2D, M-Mode, Steerable PW/CW Doppler, Colour Doppler and High Definition Colour flow. 3.12 Monitor should be 15" or more, high-resolution colour Monitor. Tilt and Swivel monitor should be able to view in all angles and all light conditions. 3.13 Colour Flow Imaging for : a. Increased lateral & spatial resolution. b. Detection of even subtle areas of turbulence, displaying a more physiological blood flow appearance without loss of frame rate. c. Colour flow with capability of automatically picking up colour flow as a function of focal depth 3.14 Tissue Colorization (B-Colour) for improved contrast resolution 3.15 Application software for Adult, Paediatric, Foetal and Peripheral Vascular and Trans oesophagal applications. (All application packages should be built into the system) 3.16 Cine loop memory- more than 120MB of memory or equivalent cineloop memory in frames/sec. a. High Frame rate review for better clarity of playback images study in slow motion. b. Quad loop with memory for pre and post image comparison of any procedure. c. Memory- 256 frames or more in quad loop. M Mode & Doppler Scroll Memory-40 seconds or more. d. Frame grabber facility for post analysis. 3.17 Various maps for pre and post processing. 3.18 ECG trigger facility. 3.19 User defined system and application presets for multi-user department. 3.20 DVD/CD writer or flash memory and USB connector 3.21 Dedicated integrated dynamic stress echo package for flexible user defined protocols with stacked sub loops facility and contrast stress protocol usable for stress echocardiography. Each 1.00 3078768.00 3078768
Labour ward, Neonatal Opthalmic equipments for Kampli new 100 Bed Taluka Hospital, Ballari District under 2515-KKRDB (Macro projects) for the year 2024-25
4 Item-4 ECHOCARDIOGRAM /2D3D/4D, Description of Function 1.1 Colour Doppler Echocardiography System is required to study the anatomical abnormalities and blood flow in the heart and associated vessels. 2 Operational Requirements 2.1 Latest generation Electronic Phased array Colour Doppler system with Minimum 50,000 digital processing channels with LIVE 3D imaging. System should be DICOM ready and capable of being interfaced with HIS/RIS/PACS. 2.2 Should be field up gradable to next generation system on site. All new software should be upgraded free of cost for at least 7 years 2.3 Frequency compounding or better technology for better resolution and penetration. 3 Technical Specifications 3.1 Latest generation Electronic Phased array Colour Doppler system with Minimum 50,000 digital processing channels with LIVE 3D imaging. 3.2 256 grey shades for sharp contrast resolutions 3.3 Adult & Paediatric Trans thoracic Cardiac, TEE (Adult & Paediatric) and Vascular Probes to be supplied which should belatest generation wide band transducers. 3.4 Harmonic Imaging- System should have following modes in harmonic with separate setting for: a. Tissue Harmonic. b. Contrast Harmonic c. Harmonic Angio. d. Quantification of harmonics imaging 3.5 Harmonic imaging capability in Adult Cardiac, Paediatric Cardiac and linear Probe 3.6 Gain control in two dimensions for additional level of flexibility to image quality control. 3.7 Real time high frequency 2D for higher resolution and low frequency Doppler for higher sensitivity in all probes. 3.8 Frame rate should be 300 FPS or more 3.9 Steerable PW/CW in all Phased Array probes. 3.10 High-definition acoustic zoom for enlarging sections of 2D and Colour flow images with more acoustic information for greater clarity and detail while maintaining an optimal frame rate. 3.11 Modes - 3D, 2D, M-Mode, Steerable PW/CW Doppler, Colour Doppler and High Definition Colour flow. 3.12 Monitor should be 15" or more, high-resolution colour Monitor. Tilt and Swivel monitor should be able to view in all angles and all light conditions. 3.13 Colour Flow Imaging for : a. Increased lateral & spatial resolution. b. Detection of even subtle areas of turbulence, displaying a more physiological blood flow appearance without loss of frame rate. c. Colour flow with capability of automatically picking up colour flow as a function of focal depth 3.14 Tissue Colorization (B-Colour) for improved contrast resolution 3.15 Application software for Adult, Paediatric, Foetal and Peripheral Vascular and Trans oesophagal applications. (All application packages should be built into the system) 3.16 Cine loop memory- more than 120MB of memory or equivalent cineloop memory in frames/sec. a. High Frame rate review for better clarity of playback images study in slow motion. b. Quad loop with memory for pre and post image comparison of any procedure. c. Memory- 256 frames or more in quad loop. M Mode & Doppler Scroll Memory-40 seconds or more. d. Frame grabber facility for post analysis. 3.17 Various maps for pre and post processing. 3.18 ECG trigger facility. 3.19 User defined system and application presets for multi-user department. 3.20 DVD/CD writer or flash memory and USB connector 3.21 Dedicated integrated dynamic stress echo package for flexible user defined protocols with stacked sub loops facility and contrast stress protocol usable for stress echocardiography. Each 1.00 3078768.00 3078768