Loading…
Loading…
1,286 results • Best match
SPL REPAIR AND STRENGTHENING OF RCC STRUCTURE AT KENDRIYA VIDYALAYA PANAGARH UNDER GE PANAGARH (DEPOSIT WORKS)
S&F LED Solar street light fitting 36 Watt high lumen greater than 50000hrs & CRI nominal 0.70 pressure die cast aluminium IP-66 enclosures including galvanized steel pole in built,lithium ion battery provide energy & backup upto 3 days when there is little or no sun, polycrystalline silicon solar panel, charge controller with dusk down sensor dimming facility, standalone autonomy 3 days complete all as specified and directed. (Excavation & earth work shall be measured separately)
PROVN OF OTM ACCN OF FD HOSP AT SAUGOR MIL STN
Note:- (i) Makes of panel provided shall be as per MNRE specification/ standard and registered in ALMM. (ii) 5% spare qty of modules shall be provided by the contractor for repair / replacement purpose. (iii) Addln module shall be provided / installed by the contractor to meet specified power output incase if the same not achived during testing and commissioning without any extra cost. (iv) Each PV module used in any solar power project must use a RF identification tag. The following information must be mentioned in the RFID used on each module:- (v) Name of the manufacturer of PV Module (vi) Name of the Manufacturer of Solar cells (vii) Month and year of the manufacture for solar cells and the module (viii) Country of origin (Make in INDIA only) (ix) I-Vcurve for the module (x) Wattage, Im, Vm and FF for the module (xi) Unique Serial No and Model No of the module (xii) Date and year of obtaining IEC PV module qualification certificate (xiii) Name of the test lab issuing EC certificate (xiv) Other relevant information on traceability of solar cells & module.
Development of Koraput Culture Centre, Koraput.
Supply Installation Testing and Commissioning of on grid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono PERC HALF CUT bifacial Crystalline silicon solar cells, net metering facility ,necessary protections, earthing, mounted on hot dip GI structure( solar panel bottom height from roof level shall not be less than 300mm, accordingly GI structure to be designed) of suitable strength with following components a complete as arequired: a) Solar Photovoltaic Module of capacity 545Wp or above, manufactured in India, conforming to IS14286 / IEC61215, IS/IEC61730 Part 1,IS/IEC61730 Part 2. Solar Photovoltaic Module conversion efficiency shall not be less than 22%. PV modules used in solar power plants /systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. b) Power Conditioning Unit (PCU) of 350 800 V DC Input voltage range and 400 V AC, three phase , 4 wire, 50Hz +/ 2.5Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree Celcious. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage,frequency. c) Data Monitoring System complete with accessories.d)Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugsand other accessories etc. asarequired.e) Lightning and surge voltage protection. f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/ conduit lugs and other accessories etc. asrequired. with all required accessories as required as per the direction of Engg in charge.Make Tata/waree/luminous/adani/panasonic. The entire SOLAR system should be Replacement Warranty will be 5 years
COMPLETION OF BALANCE WORK AGAINST PROVN OF KLP AT SAMBA
Supply and installing standalone dimmable solar street LED light with 3150 lumen , 30 Watt system wattage 120 WP panel, 100 AH battery ,12 V system, mounted on 5 mtrs Steel tabular pole, metal battery box ,with all acessories MPPT based charge controller standards : EN50530 for MPPT performance ,solar panel : IEC 61215, Electronics ,EN50530 : MPPT performance evaluation ,IEC 62124: solar standalone system performance , IEC 61347-2-13 : LED driver safety,IEC 62384 : LED driver performance ,CISPR 15 : Radio disturbance characteristics , IEC 61547 : EMC immunity requirements ,IEC60598 General requirments and tests, with overcharge protection for battery,with deep discharge protection for battery, with reverse polarity protection for panel and battery with temperature compensated charging for battery, with dimming at 50 % after 6 Hrs , Integrated MPPT charger +Driver +Bluetooth complete all as specified and directed by Engr-in- Charge. Make: Havells Cat Part No LHEWEBP7PL6S030 & Phillips Cat part : BRP409 30 W or equivalent in Bajaj.
REPAIRS / RESURFACING OF ROADS, ROAD FURNITURE AND OTHER RELATED WORKS, PAINTING TO ROAD AT BEGUMPET UNDER GE (AF) HAKIMPET
S & F Solar cat eyes aluminium alloy shall (100% water proofing design according to 65) of size 125mm x 125mm x25mm (shank 65mm) of high efficiency Mono rystafie solar panel 2.4V/0.3 watt one NI-ed rechargeable battery (1.2V/1600MA) consisting of super bright LED with 10,000 to 18,000 mcd completed as per manufactures instruction etc complete all as specified and as directed.
REPAIR TO ROAD FURNITURE AND PAINTING WORK IN DOMESTIC AND TECHNICAL AREA AT AF STN NAL
Supply and fix solar cat eye aluminum alloy shall (100% water proofing design according to( IP-65) of size 125mm x 125mm x 25mm (shank 65mm) of high efficiency Mono crystalline solar panel 2.4V/ 0.3 watt one NI-ed rechargeable battery (1.2V/ 1600MA) consisting of super bright LED with 10,000 to 18,000 mcd completed as per manufactures instructions etc. all as specified and directed