1,317 results • Best match
PROVN OF FENCING/ GRATING TO DOWNSTREAM OF CULVERT AREA AT SOLAR POWER PLANT UNDER GE (MCTE) MHOW
Excavation in post hole (or similar holes) each n. exc 0.5 cum and getting out returning filling in and ramming earth or broken rubble mixed with earth around in layers n. exc 25 cm watering and removing surplus soil to a distance n.exc 50m and making good in soft/ loose soil complete all as specified and directed.
.
Supplying Installation, Testing and Commissioning of on-grid Solar Photovoltaic Power Plant conforming to various applicable standards BIS, IEC, MNRE guidelines, the Central Electricity Authority Regulations and CPWD Specifications as amended up to date, consisting of Mono/Poly Crystalline silicon solar cells module, net metering facility, necessary control, protections, earthing, cabling, mounting structure, junction boxes, power conditioning units, Real time online web interfaced Data Monitoring System, Distribution panels, grid connecting arrangement, conduits, pipes, cable trays and other accessories etc. as required. a) High Energy Efficiency Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730- Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 23% at STC with temperature coefficient of Pmax better than -0.30% per 0C. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. Solar Modules shall be designed to operate in relative humidity upto 100% with temperature between -10 0C and +85 0C. Further, each PV module used in any solar power project must have Radio frequency identification tag with information such as name of manufacturer, month and year of manufacturing, country of origin (separately for Solar cell and module), I-V curve, Unique Serial No and Model No of the module, Wattage, Im, Vm and FF, name of test lab issuing IEC certificate. b)Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 415 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC with a variation of 10% at nominal voltage. Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 0C, Minimum IP-65 for outdoor and Minimum IP 21 for indoor, Built-in meter and data logger, MPPT, switching devices IGBT/MOSFETs and controller Microprocessor /DSP. PCU/inverter shall be capable of complete automatic operation including wake-up, synchronization & shutdown.
SITC of grid connected 1.5 MW ground mounted Solar Power Plant at Bapu Nagar Campus, IIM Bodhgaya
Custom Bid for Services - CAMC of CR System make- AGFA Healthcare pvt ltd installed in Radiology department at Eastern Railway Hospital Liluah Similar Category AMC/CAMC of Hydro Energy Power Plants AMC/CAMC of Wind Energy Power Plants AMC/CAMC of ... of Solar Energy ... Solar Energy Power ... Energy Power Plants ... Power Plants
Custom Bid for Services - CAMC of CR System make- AGFA Healthcare pvt ltd installed in Radiology department at Eastern Railway Hospital Liluah Similar Category AMC/CAMC of Hydro Energy Power Plants AMC/CAMC of Wind Energy Power Plants AMC/CAMC of Solar Energy Power Plants
Design, Supply, Installation, Commissioning and Maintenance of Grid Connected Roof Top Solar Power Plant Service - Hybrid with battery storage; To be Assessed; To be Assessed
Commissioning and Maintenance of Grid Connected Roof Top Solar Power Plant Service - Hybrid with battery storage; To be Assessed; To be Assessed
Estimate for the cost of maintenance of five line solar power fencing at Adiyankala under Rajampara FS under Ranni Range during 2026-27
Solar panel 100 Watt 12V.