Installation of Drinking water with solar system at Kismat Sukhani FPS beside Bhutnivita SSK under Sukhani G.P., within Rajganj Panchyat Samity. Activity Code- 12750201
Power condltlonlng unit with enclosure : Supply , transport , installation and commissioning of Solar Power conditioning Unit consisting of following components and features: 1) Variable frequency Drive with Inbuilt MPPT, voltage range suitable for operating pump-motor set of 1HP to 20 HP, detail mentioned In cl.6.1 2) Power Input : DC source for 1HP, 2HP and 3HP. 3) Power input : AC / DC source or hybrid for SHP and above. 4) Incomer: DC MCB 2 Pole 16 amp upto 5 HP, 25 amp for 7.SHP and 10 HP, 40 amp for 15 to 20 HP as per IS/IEC 60947-2 5) Incomer: AC MCB 4 pole 16 amp for 5.0 HP, 25 amp for 7.5HP and 10 HP, 40 amp for IS to 20 HP ar per IS/IEC 60947-1 6) Type II DC SPD of 40 KA. 7) Type II AC SPD of 40 KA for AC/ DC or Hybrid Input. 8) Dual Input (solar/Grid) 25 amp changeover switch for SHP and 7.5 HP, 40 amp for 10 HP, 63 amp for 1S to 20 HP 9) Reverse protection diode 1600 VDC with heat sink. 10) Data Logger. 11) Remote menltoring system. 12) Should have built -In EMC filters . 13) IP 65 elands for cable In and out. 14) Min. IP 54 enclosure.For detail features, protections, RMS, Communication architecture, Security, Data storage, tolerance of various parameters, standards to be qualified, etc. please refer to CI. 6.1 of technical qualification. Note: AC SPD, AC MCB and Selector switch to be provided only for item no. 3(f) to 3(I). a) For 1 HP/2 HP/3HP per structure
Installation of Drinking water with solar system at Fakdaibari Tarapith beside Mandir under Dabgram-II G.P., within Rajganj Panchyat Samity. Activity Code- 12750201
Power condltlonlng unit with enclosure : Supply , transport , installation and commissioning of Solar Power conditioning Unit consisting of following components and features: 1) Variable frequency Drive with Inbuilt MPPT, voltage range suitable for operating pump-motor set of 1HP to 20 HP, detail mentioned In cl.6.1 2) Power Input : DC source for 1HP, 2HP and 3HP. 3) Power input : AC / DC source or hybrid for SHP and above. 4) Incomer: DC MCB 2 Pole 16 amp upto 5 HP, 25 amp for 7.SHP and 10 HP, 40 amp for 15 to 20 HP as per IS/IEC 60947-2 5) Incomer: AC MCB 4 pole 16 amp for 5.0 HP, 25 amp for 7.5HP and 10 HP, 40 amp for IS to 20 HP ar per IS/IEC 60947-1 6) Type II DC SPD of 40 KA. 7) Type II AC SPD of 40 KA for AC/ DC or Hybrid Input. 8) Dual Input (solar/Grid) 25 amp changeover switch for SHP and 7.5 HP, 40 amp for 10 HP, 63 amp for 1S to 20 HP 9) Reverse protection diode 1600 VDC with heat sink. 10) Data Logger. 11) Remote menltoring system. 12) Should have built -In EMC filters . 13) IP 65 elands for cable In and out. 14) Min. IP 54 enclosure.For detail features, protections, RMS, Communication architecture, Security, Data storage, tolerance of various parameters, standards to be qualified, etc. please refer to CI. 6.1 of technical qualification. Note: AC SPD, AC MCB and Selector switch to be provided only for item no. 3(f) to 3(I). a) For 1 HP/2 HP/3HP per structure
Installation of Drinking water with solar system at Part No 18/169 beside Pucca Road under Kukurjan G.P., within Rajganj Panchyat Samity. Activity Code- 12750201
Power condltlonlng unit with enclosure : Supply , transport , installation and commissioning of Solar Power conditioning Unit consisting of following components and features: 1) Variable frequency Drive with Inbuilt MPPT, voltage range suitable for operating pump-motor set of 1HP to 20 HP, detail mentioned In cl.6.1 2) Power Input : DC source for 1HP, 2HP and 3HP. 3) Power input : AC / DC source or hybrid for SHP and above. 4) Incomer: DC MCB 2 Pole 16 amp upto 5 HP, 25 amp for 7.SHP and 10 HP, 40 amp for 15 to 20 HP as per IS/IEC 60947-2 5) Incomer: AC MCB 4 pole 16 amp for 5.0 HP, 25 amp for 7.5HP and 10 HP, 40 amp for IS to 20 HP ar per IS/IEC 60947-1 6) Type II DC SPD of 40 KA. 7) Type II AC SPD of 40 KA for AC/ DC or Hybrid Input. 8) Dual Input (solar/Grid) 25 amp changeover switch for SHP and 7.5 HP, 40 amp for 10 HP, 63 amp for 1S to 20 HP 9) Reverse protection diode 1600 VDC with heat sink. 10) Data Logger. 11) Remote menltoring system. 12) Should have built -In EMC filters . 13) IP 65 elands for cable In and out. 14) Min. IP 54 enclosure.For detail features, protections, RMS, Communication architecture, Security, Data storage, tolerance of various parameters, standards to be qualified, etc. please refer to CI. 6.1 of technical qualification. Note: AC SPD, AC MCB and Selector switch to be provided only for item no. 3(f) to 3(I). a) For 1 HP/2 HP/3HP per structure
Construction work of interlocking road for parking in front of the District Hospital in District Kushinagar. Under the Infrastructure Fund
Supply & fixing SITC of 60W ALL-IN-ONE SOLAR LIGHT AIO Solar Street Light is made with High Efficiency 12V 90W Mono Crystalline Solar PV Module,12.8 42V Ah Lithium Ferro Phosphate battery with inbuilt BMS technology, Min-7800, Max-9000 lumens High Efficacy LED( OSRAM/NICHIA),50000 hours Burning Hrs, MPPT Solar Charge Controller and Aluminum Extruded body & is specially programmed to automatically control the dimming and brightness of light, which increases the backup time. Make:Wipro/Philips/Havells M.R.
State Plan-State Plan-2025 - 26- Modification of OHSR for accomodating PH Section Office Mankada underneath the 28 LL capacity OHSR at Moochikkal
OD119294/2025-2026:Supply, Installation, Testing and Commissioning of ongrid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:- a) Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency. c) Data Monitoring System complete with accessories. d) Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required. e) Lightning and surge voltage protection. f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/conduit lugs and other accessories etc. as required.
Design, Supply, Installation, Programming, Testing and Commissioning of New Hot Standby Electronic Interlocking System at Waghodiya , Jarod and Lotna Stations and EI alteration at Dabhoi and Samlaya station along with Supply, Installation, Testing and Commissioning of various Indoor and Outdoor Signaling System with BPAC in Dabhoi-Waghodiya -Jarod - Lotna-Samlaya Section in connection of provision of Gauge Conversion Work under Dy. CSTE Construction, Vadodara, Gujarat (Western Railway)
Hooter cum Strobe. Total 5342687.08 Supply and Installation of Solar Power system for 110volt/300AH battery bank load as IPS System. Item- 71 Each panel containing the following items. S No. Item Description of Item Unit Qty Rate Amount No