Loading…
Loading…
1,279 results • Best match
Improvements to Hydro mechanical components
Suppling and Fixing of Solar Street light 60 W 2 IN 1 SOLAR STREET LIGHT, 12.8V 54 AH LITHUM FERRO BATTERY, 12 V 200 WATT PANEL AND OTHER ACCESSERIES. complete as per specifications and as per dire...
BADHAI AGRI BUSINESS PRODUCER COMPANY
Solar Panel Foundation and all related Items Hybrid 60 KW 240V Three Phase Inverter
INSTALLATION OF SOLAR DRINKING WATER TANK AT SANSAD IV SARKARPARA,PART NO-17/151,15TH FC (TIED),ACTIVITY ID-110940246
Power conditioning unit with enclosure: Supply, transportation, Installation and commissioning of Solar Power Conditioning Unit consisting of following components and features 1. Variable frequency Drive with inbuilt MPPT, Voltage range suitable for operation pump-motor set of 1HP to 20 HP, detail mentioned in cl 6.1 2. Power input: DC source for 1HP, 2HP and 3HP 3. Power input: AC/DC source or hybrid for 5HP and above 4. Incomer: DC MCB 2 Pole 16 amp upto 5HP, 25 amp for 7.5HP and 10HP, 40 amp for 15 to 20 HP as per IS/IEC 60947-2 5. Incomer: AC MCB 4 Pole 16 amp upto 5HP, 25 amp for 7.5HP and 10HP, 40 amp for 15 to 20 HP as per IS/IEC 60947-2 6. Type II DC SPD of 40 KA 7. Type II AC SPD 40 KA for AC/DC or Hybrid input 8. Dual input (Solar/Grid) 25 amp changeover switch for 5H and 7.5HP, 40 amp for 10HP, 63 amp for 15 to 20 HP 9. Reverse protection diode 1600 VDC with heat sink 10. Data logger 11. Remote monitoring system 12. Should have built –in EMC filters 13. IP 65 glands for cable in and out 14. Min. IP 54 enclosure. For details features, protection, RMS, communication architecture, security Data storage, tolerance or various parameters, standards to be qualified, etc. please refer to cl. 6.1 of technical qualification. For 1 HP capacity Pump-motor Set with DC input
INSTALLATION OF SOLAR DRINKING WATER TANK AT SANSAD VIII OLD PANDA PARA,PART NO-17/155(TIED),,15TH FC ,ACTIVITY ID-110941500,
Power conditioning unit with enclosure: Supply, transportation, Installation and commissioning of Solar Power Conditioning Unit consisting of following components and features 1. Variable frequency Drive with inbuilt MPPT, Voltage range suitable for operation pump-motor set of 1HP to 20 HP, detail mentioned in cl 6.1 2. Power input: DC source for 1HP, 2HP and 3HP 3. Power input: AC/DC source or hybrid for 5HP and above 4. Incomer: DC MCB 2 Pole 16 amp upto 5HP, 25 amp for 7.5HP and 10HP, 40 amp for 15 to 20 HP as per IS/IEC 60947-2 5. Incomer: AC MCB 4 Pole 16 amp upto 5HP, 25 amp for 7.5HP and 10HP, 40 amp for 15 to 20 HP as per IS/IEC 60947-2 6. Type II DC SPD of 40 KA 7. Type II AC SPD 40 KA for AC/DC or Hybrid input 8. Dual input (Solar/Grid) 25 amp changeover switch for 5H and 7.5HP, 40 amp for 10HP, 63 amp for 15 to 20 HP 9. Reverse protection diode 1600 VDC with heat sink 10. Data logger 11. Remote monitoring system 12. Should have built –in EMC filters 13. IP 65 glands for cable in and out 14. Min. IP 54 enclosure. For details features, protection, RMS, communication architecture, security Data storage, tolerance or various parameters, standards to be qualified, etc. please refer to cl. 6.1 of technical qualification. For 1 HP capacity Pump-motor Set with DC input
INSTALLATION OF SOLAR DRINKING WATER TANK AT SANSAD VI KORANI PARA, PART NO-17/153,15TH FC(TIED), ,ACTIVITY ID-110941023
Power conditioning unit with enclosure: Supply, transportation, Installation and commissioning of Solar Power Conditioning Unit consisting of following components and features 1. Variable frequency Drive with inbuilt MPPT, Voltage range suitable for operation pump-motor set of 1HP to 20 HP, detail mentioned in cl 6.1 2. Power input: DC source for 1HP, 2HP and 3HP 3. Power input: AC/DC source or hybrid for 5HP and above 4. Incomer: DC MCB 2 Pole 16 amp upto 5HP, 25 amp for 7.5HP and 10HP, 40 amp for 15 to 20 HP as per IS/IEC 60947-2 5. Incomer: AC MCB 4 Pole 16 amp upto 5HP, 25 amp for 7.5HP and 10HP, 40 amp for 15 to 20 HP as per IS/IEC 60947-2 6. Type II DC SPD of 40 KA 7. Type II AC SPD 40 KA for AC/DC or Hybrid input 8. Dual input (Solar/Grid) 25 amp changeover switch for 5H and 7.5HP, 40 amp for 10HP, 63 amp for 15 to 20 HP 9. Reverse protection diode 1600 VDC with heat sink 10. Data logger 11. Remote monitoring system 12. Should have built –in EMC filters 13. IP 65 glands for cable in and out 14. Min. IP 54 enclosure. For details features, protection, RMS, communication architecture, security Data storage, tolerance or various parameters, standards to be qualified, etc. please refer to cl. 6.1 of technical qualification. For 1 HP capacity Pump-motor Set with DC input
INSTALLATION OF SOLAR DRINKING WATER TANK AT SANSAD XXVI ,SOUTH SUKANTA NAGAR,PART NO-17/173, (TIED),15TH FC ,ACTIVITY ID-110948827
Power conditioning unit with enclosure: Supply, transportation, Installation and commissioning of Solar Power Conditioning Unit consisting of following components and features 1. Variable frequency Drive with inbuilt MPPT, Voltage range suitable for operation pump-motor set of 1HP to 20 HP, detail mentioned in cl 6.1 2. Power input: DC source for 1HP, 2HP and 3HP 3. Power input: AC/DC source or hybrid for 5HP and above 4. Incomer: DC MCB 2 Pole 16 amp upto 5HP, 25 amp for 7.5HP and 10HP, 40 amp for 15 to 20 HP as per IS/IEC 60947-2 5. Incomer: AC MCB 4 Pole 16 amp upto 5HP, 25 amp for 7.5HP and 10HP, 40 amp for 15 to 20 HP as per IS/IEC 60947-2 6. Type II DC SPD of 40 KA 7. Type II AC SPD 40 KA for AC/DC or Hybrid input 8. Dual input (Solar/Grid) 25 amp changeover switch for 5H and 7.5HP, 40 amp for 10HP, 63 amp for 15 to 20 HP 9. Reverse protection diode 1600 VDC with heat sink 10. Data logger 11. Remote monitoring system 12. Should have built –in EMC filters 13. IP 65 glands for cable in and out 14. Min. IP 54 enclosure. For details features, protection, RMS, communication architecture, security Data storage, tolerance or various parameters, standards to be qualified, etc. please refer to cl. 6.1 of technical qualification. For 1 HP capacity Pump-motor Set with DC input