Loading…
Loading…
1,276 results • Best match
Creation Of New Sources Of Drinking Water Facility With Solar PV At Khetrasingh Sansad Within Buraganj Gram Panchayet 2025-26 Under 15th FC Tied Fund.
W.R.I D.D. Schedule of Rates 2021,ch. 12, item no. 3/b Power conditioning unit with IP54 enclosure: Supply , transport,Installation and commissioning of IP 54 protected enclosured inverter unit qualifying IEC 61683 Efficiency measurement and IEC 60068-2 environment standard suitable for 3 phase A.C. motor, IGBT based high voltage switching inverter with MPPT technology, to take care of the varition of sun light and will be suitably mounted inside the metal enclosure. Inverter should have protection against dry run, over current, under current, over voltage, under voltage, short circuit etc.system should be able to run at low sunss a day run should be possible during normal sunshine condition inverter should have option to auto start trip off due to low light/cloudy situation except for dry run. Inverter should be provided with a display to show the various parameter by the user such as voltage, current, solar panel DC voltage, Inverter IGBT tempreture, out put AC voltage, output frequency, pump flow ( direct or calculated method), Irradiation ETC. The system should store the data at a set interval, be capable to transfer it to external storage device and support communication of its operational parameter and logs over modbus protocol it should also monitor and save total run time, total water pumped etc. there should be provision for interfacing GPRS based data transmission Amrit/Havels/Suriya or equvalent. B) For 1 HP capacity pump motor set.(As per direction of EIC) ( as per Govt approved)
Construction of Type-A Building less Sub-Health Centre (SHCs)-HWCs (AAM) under PM-ABHIM for FY 2025-26 at Domohani SC under Binpur-I Block, Jhargram District.
SITC of 1.1 kWp off-grid Rooftop Solar PV Power Plant including Additional 1 year of Comprehensive Maintenance
Construction of Type-A Building less Sub-Health Centre (SHCs)-HWCs (AAM) under PM-ABHIM for FY 2025-26 at Rashikpur SC under Binpur-I Block, Jhargram District.
SITC of 1.1 kWp off-grid Rooftop Solar PV Power Plant including Additional 1 year of Comprehensive Maintenance
REPAIR/MAINT OF GEYSERS, SOLAR GYSER, CEILING FAN, WALL MOUNTED FAN, EXHAUST FAN AND ALLIED WORKS AT AREA UNDER GE (NORTH) BINNAGURI
SOLAR WATER GEYSER Disconnecting of water connection and dismantling complete solar water heating system of capacity 300 ltrs per day including hot & cold water pipes and hot water tank complete and refixing after repairing the system fixing back in position and testing complete all as specified and directed by Engineer-in-charge. Note : Rates quoted by the contractor shall deemed to be included for :- (a) Making good the worn out missing nuts bolts, washers, union, sockets, flanges and screws etc. (b) Descaling/ desludging, cleaning and washing of the solar panel, hot water pipes, copper tubes, hot and cold water tanks by using appropriate chemicals and re-assembling the panel including welding of collector fins as required. (c) Painting of staging, solar panel frame, hot water tank frame with applying one coat of synthetic enamel paint including preparation of old painted steel surfaces of any description (e) All other materials shall be measured and paid separately under respective items.
ELECTRICAL ITEM
Supply and Fixing of solar street light fitting 12 watt having high efficiency Mono Crystalline Solar PV Module, Lithium Ferro Phosphate battery with in-built BMS technology, High Efficacy LED MPPT Solar Charge Controller and Aluminium Extruded body & specially programmed to automatically control the dimming and brightness of light, which increases the backup time, etc complete all as specified and directed
Repair/ maint of DG Sets, lifts, sewage installation etc under AGE E/M at GE Gurdaspur.
S&F in repair installaton commissioning and testing of all in one solar street lighting system complete with solar panel, with IP 65 protection, solar panel, battery, charging circuit, LED driver are integrated in single casing, mounted on existing pole, connecting cable battery box reflector on its back including LED light of 40 W and above, aluminum alloy case, built in pipe mounting bracket, 120degrees wide lighting angle, efficiency min 95% all as specified and directed.