Loading…
Loading…
1,319 results • Best match
8522/E8 REPAIR AND REPLACEMENT OF MODULAR SWITCH, SOCKET, WIRING UNSERV LED LIGHT FITTING, GARDEN LIGHT, PATH LIGHT AND BLDG SECURITY LIGHT AND CONNECTED WORKS UNDER GE (EAST) BAREILLY
M & L for replacement of heating element with plating 3 KW shock proof of existing shape and size suitable for Solar water heater as per requirement all as directed.
Construction of Mela Singh Chowk with RMC M40 Cement Concrete Pavement in Model Town Ward No.-08, mcynr-jag Recall
[34.36]Solar RPM/ Stud Providing and installation of solar cat eye produced from an engineered polymer selected for superior impact resistance and weather-ability. The top of the solar stud should be transparent for solar charging and light output in active mode. The base of the body shall be yellow or neutral white as approved by Engineer In-charge. The marker shall incorporate a solar panel (comprising of solar cells) for converting solar energy into electricity, a storage device for storing the energy, LEDs for illumination and a design for providing 360 degree smooth illumination. The Solar stud shall be round in shape for providing illumination in all directions. The solar stud shall also have high reflective polycarbonate/ methyl methecrylate lenses for conspicuity in passive mode and dual shanks for improved road presence. The solar studs are intended for application directly onto pavement surfaces and shall be applied with epoxy resin adhesives designed for use with raised pavement markers and as supplied by the marker manufacturer separately. The solar cat eye shall be of height: 65 ± 2 mm & Maximum Diameter: 136 ± 5 mm. The body of the solar cat eye shall be resistant to dust and water ingress as per IP 65 standards. The marker shall support a load of 13635 Kg tested in accordance with ASTM D4280. [Through Rate]
CONSTRUCTION OF GOVT SR. SEC. SCHOOL AT BAJWARA, DISTRICT HOSHIARPUR (PUNJAB)
Supply, Installation, testing & Commissioing of Grid interactive PV System Solar Power Plant (i.e connected to utility grid) of Minimumcapacity including required quantities of SPV modules (High power density bifacial monocrystalline solar modules with a capacity of +400 watts) formed into arrays, their mounting arrangement, Power conditioning units (i.e String Solar Inverter with 2Nos. GI Chemical earthing with suitable size GI strip upto string inverter and AC & DC distribution panel), required DC & AC distribution panels with surge protection units, cabling from terrace to main distribution board through Cable tray, Bi Directional Energy Meter, Provision of Lightening Arrestor & 2 Nos. GI chemical earthing with suitable size GI strip upto Lightning arrestor, Hot dip galvanized MS Mounting Structures (1No. GI Chemical earthing with suitable size GI strip upto mounting structure) should be designed to withstand the speed for the wind Zone of the location (150 Km/hr-170 Km/hr) Complete in all respect with transportaion, fabrication, labour & Civil Work etc. Features :- 1. Solar PV Module warranty 25 Years & certified under IS/IEC 61730 I & II IS/IEC 61701 & IS/EC 14286 2. Power Conditioning unit (string solar inverter) & certified under IEC/EN 62109-1, IEC/EN 62109-2, EN 61000-6-2, EN 61000-6-3, IEC 61683, EN 50530, IEC 60068-2-1, 2, 14, 30, EN 60529 3. Structure 25 Years service life with AMC & certified under IS 2062 2011 4. Complete Plant insurance for the period of 5 Years (Excluding Theft of the Material) 5. Annual Maintenance contract for the period of 10 Years Conditions: # The Plant will be installed as per MNRE and GOI guidelines and specifications. (Detail of material as per Annexure-I attached) #The work will got done from approved MNRE (Misitry of New and Renewable Energy)/ PEDA (Punjab Energy Development Agency) contractor/PWD enlisted contractor subject to the condition that PWD enlisted contractor will get work done from /MNRE/PEDA approved contractor. #The capacity of solar power plant my increase or decrees as availability of site it can also be totally removed from executive end The Rate are inclusive of all taxes including GST, Bi-directional meter testing charges uni-directional meter cost and PSPCL connection Charges
AMRUT 2.0- Augmentation of WSS to Kollam Corporation- Design and construction of 20LL capacity OHSR at Jala Bhavan Compound, Kollam
OD276374/2025-2026:Supply installation All type of testing, trial run and commissioning of solar on grid plant with advanced Mono Perc Half Cut Solar panels, Structures to mount panels, DC cables and connectors DC junction Box, Inverters . AC junction BoxLink,,solar meter with Box, AC cables, Link/CB, TPN Box, Net Meter with approval of KSEB approval and all other electrical and mechanical accessories complete as per the direction of departmental officers and in accordance with Inspectorate standards. All paperwork, statutory fees and allied works with the Electrical inspectorate and KSEB Limited for the approval and to be got approved by Electrical Inspectorate and KSEB Limited
REPAIR/ MAINT OF ROAD NEAR JCOS/ ORS/CIVILIAN MARRIED ACCN AT ZONE A AREA UNDER GE (I) GOS
S&F in repair solar cat eyes/road studs size (mm) 125L x 125B x 25H including stem height 53mm approx housing dia cast aluminium (grade LM-6) fully water proof and weather proof and weatherproof coating visible distance upto 400mtr LED-6 super bright amber led (3 Nos each side) yellow charged, flush frequency 1.2 Hz-1.8Hz including solar panel 3.5V/110MA & battery one PC sub ‘C’ type Ni-Cd rechargeable battery 1.2V/2.5AH temp range 20C to 70C fixed on road for roadway sign complete as per manufacturer’s instruction and directed by Engr-in-Charge Make- 3M/Avery Dennision/Dark Eye/Green/Greenlite/Road Star Cat Part No. GSR-909 or Equivalent.
Augmentation of Water Supply Scheme Village Dhandoli and SC Colony in Block Phagwara, District Kapurthala (Under head NABARD XXXI/State Share/4215)
Providing, Fixing, Installing, Commissioning, Solar Panel Energy System (Monocrystalline) for amount of electric power required for running electric motor and other appliances such as fan, tube, Bulb etc in water works site. including Bi-directional meter and inverter of suitable capaity as per guidelines issued by PEDA complete in all respects.